- 4 -

STANDARD INSTALLATION PROCEDURE, MV6W

CONTENTS INCLUDE:

     (1) Wall mount Bracket

     (1) Dome base

     (1) Dome

     (1) Dome liner

     (1) Camera swivel plate

     (1) Camera mount with camera, lens, and PC Board

     (1) Camera adjustment arm

     (1) Camera adjustment template

     (2) 4-40 x 1/4" screws

     (1) 8-32 x 3/8" screw

INSTALLATION

1

. Locate the area on the wall where the bracket is to be

mounted.  Cut a hole no larger than 1" in diameter and

feed the necessary wires/cable through (Figure 1).

2

. Feed wires/cable through the hole in the back side of the

bracket and out through end of the pipe.

3

. Attach the bracket to the wall with fasteners that best fit

the application.

HOUSING INSTALLATION

   1

. Once the bracket  is secure, feed all wires/cable through

       the top dome.  Slide the top dome onto the bottom of

       the bracket; the grommet should be secure around the

       bracket pipe (Figure 2).

4

. Once the housing has been secured to the bracket, slide

the top dome back down along the bracket until it fits on

top of the housing.  The grommet will keep the top dome in

place.

TOP DOME

GROMMET

3/4" CONDUIT CONNECTOR

Figure 1

Figure 2

Figure 3

2

. Once the top dome has been placed on the bracket, feed all

wires/cable through the 3/4" conduit connector and camera

housing.

3

. Slide the housing onto the bracket, then tighten down the screw

on the 3/4" conduit connector (Figure 3).

    Note:

  The connector will need to be tightened completly

               down to secure the housing to bracket.

Make necessary camera adjustments and complete the

installation process as specified elsewhere in these instructions.

10.8"

7.0"

5.4"

3.4"

3.3"

PCF6W, PCV6W  Dimensions

Summary of Contents for PCF2

Page 1: ...orwared so that the screws hold the base to the sur face Tighten the screws Dome Tab Slots Key Hole Slots Wire or Cable Entry ATTACHING HOUSING PCF6 PCV6 PENDANT MOUNT 1 Install 3 4 EMT pipe not provided to the desired length 2 Slide the top dome 10 to 12 onto the pipe leaving enough room to work Run the wiring through the EMT connector and wiring hole inside the top of the housing 3 Slide complet...

Page 2: ... Note Adjust camera lens as close as possible to the outline of the bottom of the template Camera swivel plate Camera Adjustment Arm Camera Mount with Camera and PC Board Loosen screws to adjust camera Tab Tab Place the lens as close to this edge as possible Camera Adjustment Template Liner Dome Tabs Base 3 Fine focusing see diagram below Fixed Lens Manually rotate the lens until a clear picture i...

Page 3: ...ixed Focal Lens Series 4 8mm Vari Focal Lens Series PCF1 PCF6W PCF6 PCF5 PCF4 PCF3 PCF2 PCV6W PCV6 PCV5 PCV4 PCV3 PCV2 PCV1 361 mm H x 272 mm V Equivalent to scanning area of 1 4 pick up tube 525 lines 60 fields 30 frames 15 734 kHz 59 94 kHz Internal Synchronization 1 0 V p p NTSC Composite 75 ohms BNC Connector 330 lines at center area 46 dB with AGC OFF 0 5 Footcandle 5 Lux at F2 0 0 5 Footcand...

Page 4: ...all wires cable through the top dome Slide the top dome onto the bottom of the bracket the grommet should be secure around the bracket pipe Figure 2 4 Once the housing has been secured to the bracket slide the top dome back down along the bracket until it fits on top of the housing The grommet will keep the top dome in place TOP DOME GROMMET 3 4 CONDUIT CONNECTOR Figure 1 Figure 2 Figure 3 2 Once ...

Page 5: ... is intact Failure to comply with the foregoing could result in the unit separating from the support structure and falling with resultant damages or injury to anyone or anything struck by the falling unit UNPACKING Unpack carefully Electronic components can be damaged if improperly handled or dropped If an item appears to have been damaged in shipment replace it properly in its carton and notify t...

Reviews: