background image

- 3 -

6.0"

5.0"

1.0"

5.0" Dia.

6.0" Dia.

PCF2, PCV2 Dimensions

CAUTION:

  To prevent fire or shock hazard, the UL-Listed wire

                   VW-1, style 1007, should be used for the cable for

                   24 VAC input terminals.

Wiring Chart-Cable Distance

This Chart is based on a 12VDC power supply with the
maximum Amp draw at .500 amps.

WIRE          20          18          16

    FT.         180'       300'       480'

5.75"

6.0"

PCF6, PCV6 Dimensions

Specification

Lens Type

Minimum Illumination

Weight

Power Source

Ambient Operating
Temperature

Dimensions

at DC Source

AGC

Vertical

at AC Source

White Balance

ELC

Synchronization

Video Output

Horizontal Resolution

Signal-to-Noise Ratio

Horizontal

Angular Field of View

Vertical

Horizontal

Scanning

Scanning Area

Model Number

Ambient Operating
Humidity

3 - 8mm Fixed Focal Lens Series

4 - 8mm Vari- -Focal Lens Series

PCF1

PCF6W

PCF6

PCF5

PCF4

PCF3

PCF2

PCV6W

PCV6

PCV5

PCV4

PCV3

PCV2

PCV1

361 mm (H) x 272 mm (V) (Equivalent to scanning area of 1/4" pick-up tube)

525 lines / 60 fields / 30 frames

15.734 kHz

59.94 kHz

Internal Synchronization

1.0 V (p-p) NTSC Composite 75 ohms / BNC Connector

330 lines (at center area)

46 dB (with AGC OFF)

0.5 Footcandle (5 Lux) at F2.0

0.5 Footcandle (5 Lux) at F2.0 - 1.0 Footcandle
                                                       (10 Lux) at F2.8

Horizontal 53.4˚

Horizontal 51.7 - 26.7˚

Vertical 40.0˚

Vertical 38.4 - 20.0˚

On (Preset)

On (Preset)

ATW (Preset)

-10˚C - +50˚C (14˚F - 122˚F)

Less than 90%

2.82"
4.6"
2.82"

W
H
D
kg
lbs

2.82"
4.6"
2.82"

6.0"
6.0"
6.0"

6.0"
6.0"
6.0"

3.15"
4.9"
3.2"

3.15"
4.9"
3.2"

5.25"
3.0"
3.625"

5.25"
3.0"
3.625"

15.9"
11.2"
15.9"

15.9"
11.2"
15.9"

6.0"
6.0"
6.0"

6.0"
6.0"
6.0"

6.0"
10.8"
7.0"

6.0"
10.8"
7.0"

0.45
1

0.45
1

1.8
4

0.45
1

0.45
1

0.45
1

0.45
1

1.8
4

0.68
1.5

0.68
1.5

0.68
1.5

0.68
1.5

0.91
2

0.91
2

24 VAC, 40 ma
12 VDC, 80 ma

Summary of Contents for PCF2

Page 1: ...orwared so that the screws hold the base to the sur face Tighten the screws Dome Tab Slots Key Hole Slots Wire or Cable Entry ATTACHING HOUSING PCF6 PCV6 PENDANT MOUNT 1 Install 3 4 EMT pipe not provided to the desired length 2 Slide the top dome 10 to 12 onto the pipe leaving enough room to work Run the wiring through the EMT connector and wiring hole inside the top of the housing 3 Slide complet...

Page 2: ... Note Adjust camera lens as close as possible to the outline of the bottom of the template Camera swivel plate Camera Adjustment Arm Camera Mount with Camera and PC Board Loosen screws to adjust camera Tab Tab Place the lens as close to this edge as possible Camera Adjustment Template Liner Dome Tabs Base 3 Fine focusing see diagram below Fixed Lens Manually rotate the lens until a clear picture i...

Page 3: ...ixed Focal Lens Series 4 8mm Vari Focal Lens Series PCF1 PCF6W PCF6 PCF5 PCF4 PCF3 PCF2 PCV6W PCV6 PCV5 PCV4 PCV3 PCV2 PCV1 361 mm H x 272 mm V Equivalent to scanning area of 1 4 pick up tube 525 lines 60 fields 30 frames 15 734 kHz 59 94 kHz Internal Synchronization 1 0 V p p NTSC Composite 75 ohms BNC Connector 330 lines at center area 46 dB with AGC OFF 0 5 Footcandle 5 Lux at F2 0 0 5 Footcand...

Page 4: ...all wires cable through the top dome Slide the top dome onto the bottom of the bracket the grommet should be secure around the bracket pipe Figure 2 4 Once the housing has been secured to the bracket slide the top dome back down along the bracket until it fits on top of the housing The grommet will keep the top dome in place TOP DOME GROMMET 3 4 CONDUIT CONNECTOR Figure 1 Figure 2 Figure 3 2 Once ...

Page 5: ... is intact Failure to comply with the foregoing could result in the unit separating from the support structure and falling with resultant damages or injury to anyone or anything struck by the falling unit UNPACKING Unpack carefully Electronic components can be damaged if improperly handled or dropped If an item appears to have been damaged in shipment replace it properly in its carton and notify t...

Reviews: