S-plan Wiring
PAW cylinders
can be
fitted with all types of boilers and heat
pumps operating using room and
cylinder thermostats.
Please follow upper diagram:
‘Wiring for Standard Heat Pump’.
Thermistor controlled Heat
Pumps/Boilers
Many popular Heat Pumps now
use a thermistor principle. A
thermistor temperature sensor is
supplied with the Heat Pump to
attach to the cylinder.
Temperature information is
relayed back to the Heat Pump
control system.
A Pocket is provided (see below
to secure the sensor on the
PAW cylinder. The
probe is run through a channel
from base of cylinder to the
immersion housing and housed
there in a pocket. The thermistor
cable should be secured using
the supplied clamps in the bottom
opening of the channel. A
motorised valve must be used in
accordance with Building
Regulation G3. This is wired from
the additional cylinder
thermostat, wired as high limit
stat. Please follow lower diagram:
‘Wiring for Thermistor Controlled
Heat Pump”
Using Additional Cylinder Thermostat
as high limit stat only:
- coil the grey temperature
probe wire inside additional
cylinder thermostat box and insert
black probe into thermostat pocket
of cylinder then turn dial on front to
number 5
Channel running
from base of cylinder
Pump
flow
2-port valve
(supplied)
Zone valve
(not supplied)
Automatic
bypass
Radiators/
UFH
HP/Boiler
Piping
Diagram
Zone Valve (DHW)
(supplied)
1 2
2
3
1
T6360B
3
5
7
3
G/Y
L N E 4
G Br B
l
O
L N E
L N E
Pump
1 2 3
2 3
2 3
2
2
3
1
V4043H
Cylinder
Thermostat
(supplied) Wired as
high limit stat
Isolated Mains
Supply From
Fused Spur
Zone Valve (Htg)
(not supplied)
Room
thermostat
L N E
6
9
2
3
1
V4043H
G Br B1 O
G/Y
4
8
10
Wiring for Thermistor Controlled Heat Pump
1
2
Thermistor
Thermistor wire
Connected to
Heat Pump
control
system
1 2
2
3
1
T6360B
3
5
7
3
G/Y
L N E 4
G Br
B
l
O
L N E
L N E
Heat Pump
Pump
1 2 3
2 3
2 3
2
2
3
1
V4043H
Cylinder
Thermostat
(supplied)
Isolated Mains
Supply From
Fused Spur
Zone Valve (Htg)
(not supplied)
Room
thermostat
L N E
6
9
2
3
1
V4043H
G Br
B1 O
G/Y
4
8
10
Wiring for Standard Heat pump
1
2
Zone Valve (DHW)
(supplied)
N L C NC NO
N L C NC NO
ST6400
Programmer
HW
ON
HTG
ON
ST6400
Programmer
HW
ON
HTG
ON
Heat pump differential controler