AHU Kit – Installation Instructions – 07/2023
Product description
3
System lineup – ECO G systems
Capacity
Outdoor unit
AHU Kit
HP
kW
5
16
all ECO G outdoor units
PAW-160MAH3M
1
10
28
all ECO G 2-way outdoor units
PAW-280MAH3M
2
20
56
all ECO G 2-way outdoor units
PAW-560MAH3M
3
1 PAW-160MAH3M:
● Like any other standard indoor unit, PAW-160MAH3M can be installed in combination with all ECO G
outdoor units.
● Mixed installation with standard indoor units is possible. However, in this case one additional RAP valve
(CZ-P160RVK2) must be installed in the unit connection pipe, unless the complete system is exclusively
used in cooling only operation or in a 3-way system with heat recovery box.
2
PAW-280MAH3M:
● Like any other indoor unit of similar capacity, PAW-280MAH3M can be installed in combination with all
ECO G 2-way outdoor units only.
● Mixed installation with standard indoor units is possible. However, in this case two additional RAP
valves (2 x CZ-P160RVK2) must be installed in the unit connection pipe, unless the complete system is
exclusively used in cooling only operation. For further restrictions in mixed installations, please refer to
the system descriptions in the corresponding ECO G technical data books.
● Connection to ECO G 3-way systems is not allowed.
3
PAW-560MAH3M:
● Like any other indoor unit of similar capacity, PAW-560MAH3M can be installed in combination with all
ECO G 2-way outdoor units only.
● Mixed Installation with standard indoor units is not possible.
● Connection to ECO G 3-way systems is not allowed.
System lineup – PACi systems
Capacity
(kW)
Re
fri
ge
ran
t
Outdoor unit
AHU Kit
PACi
1
Single-phase units
Three-phase units
20.0
R32
–
U-200PZH2E8
PAW-280PAH3M-1
2
25.0
R32
–
U-250PZH2E8
1 With PACi systems, only 1-to-1 installations are allowed (e.g. 1 x PACi outdoor unit + 1 x PAW-280PAH3M). Combina
-
tions with more than 1 outdoor unit or more than 1 AHU Kit are not possible.
2
Mixed installation with standard indoor units is not allowed.
System lineup – PACi NX systems
Capacity
(kW)
Re
fri
ge
ran
t
Outdoor unit
AHU Kit
PACi NX Standard
1
PACi NX Elite
1
Single-phase units
Three-phase units
Single-phase units
Three-phase units
2.5
R32
U-25PZ3E5
–
–
–
PAW-280PAH3M-1
2
3.6
R32
U-36PZ3E5
–
U-36PZH3E5
–
5.0
R32
U-50PZ3E5
–
U-50PZH3E5
–
6.0
R32
U-60PZ3E5A
–
U-60PZH3E5
–
7.1
R32
U-71PZ3E5A
–
U-71PZH4E5
U-71PZH4E8
10.0
R32
U-100PZ3E5
U-100PZ3E8
U-100PZH4E5
U-100PZH4E8
12.5
R32
U-125PZ3E5
U-125PZ3E8
U-125PZH4E5
U-125PZH4E8
14.0
R32
U-140PZ3E5
U-140PZ3E8
U-140PZH4E5
U-140PZH4E8
1 With PACi NX systems, only 1-to-1 installations are allowed (e.g. 1 x PACi NX outdoor unit + 1 x PAW-280PAH3M-1).
Combinations with more than 1 outdoor unit or more than 1 AHU Kit are not possible.
2
Mixed installation with standard indoor units is not allowed.