4 Trial run configuration
4.4
Make protective settings
The protective settings in the bottom part of the “TrialRun” tab are directly linked to the
servo driver parameters Pr5.12, Pr5.13, and Pr5.14. If you change a value on this tab, it will
automatically be set in the driver.
Protective parameters
• “Over-load level setup”: Max. torque limit value in percent.
• “Over-speed level setup”: Max. speed limit value in rev/min. Select Auto-set (“Over-speed
level setup”) to set a value twice the JOG speed.
• “Motor working range setup”: Working range of the motor per revolution. The value is
calculated based on the two previous values.
• “MAX (pulse)”, “MIN (pulse)”: Use the “JOG” buttons to set limit values for the movement
in positive and negative direction.
(1)
(1) Current value
Maximum values for the movement in positive and in negative direction
If an error occurs, open the “Alarm” tab. You can find instructions on how to solve the issue
on the right side of the tab under “Treatment”. In most cases, increasing the maximum value
on the “TrialRun” tab or in the parameter list should solve the problem.
(1)
“Alarm” tab
10
QS5000_V1.0_EN