CONDITION:
BURST SIGNAL OFF / 75 ohm
TERMINATED
Fig. E1
Fig. E2
11.4.4. PG SHIFTER ADJUSTMENT / (AUTOMATIC)
Fig. E3
PROCEDURES
FIP DISPLAY
Press the FF and EJECT Keys
simultaneously for 3 seconds.
Press the FF and EJECT Keys
simultaneously twice.
Press the EJECT key for 3
seconds.
Press the CH UP key once.
Insert the Alignment cassette
tape. (PAL:VFJ8125H3F)
When the sequence of the automatical adjustment
has been terminated, the following action has been
made.
*SUCCEED: The cassette tape is ejected.
*ERROR : The "F2"is displayed on the FIP.
(Check the Servo/Syscon circuit and
Cylinder unit.)
Release the Service mode by pressing the EJECT
and FF keys simultaneously in 6 times until the FIP
becomes normal indication.
11.4.5. VIDEO FREQUENCY RESPONSE ADJUSTMENT
Fig. E4
54