TABLE (1L-1min.test)
RATED OUTPUT
TEMPERATURE RISE
1100W(IEC705-88)
Min. 16.9°F(9.4°C)
1200W(IEC705-88)
Min. 18.5°F(10.3°C)
12. PROCEDURE FOR MEASURING MICROWAVE
ENERGY LEAKAGE
WARNING
Check for radiation leakage after every servicing.
Should the leakage be more than 2 mW/cm
2
(1mW/
cm
2
for Canada) inform PASC, PSC, or PCI
immediately. After repairing or replacing any
radiation safety device, keep a written record for
future reference, as required by D.H.H.S. and
Health and Welfare Canada regulation. This
requirement must be strictly observed. In addition,
the leakage reading must be recorded on the
service repair ticket while in the customer’s home.
NOTE:
The U.S. Government standard is 5 mW/cm
2
while in the customer’s
home. 2mW/cm
2
stated here is our own voluntary standard. (1mW/cm
2
for Canada)
12.1. Equipment
- Electromagnatic radiation monitor
- Glass thermometer 212°F or 100°C
- 600cc glass beaker
12.2. Procedure for measuring radiation leakage
Note before measuring.
- Do not exceed meter full scale deflection. Leakage monitor should
initially be set to the highest scale.
- To prevent false readings the test probe should be held by the grip
portion of the handle only and moved along the shaded area in Figure
no faster than 1 inch/sec (2.5cm/sec).
- Leakage with the outer panel removed ...... less than 5mW/cm
2
.
- Leakage for a fully assembled oven with door normally closed ...... less
than 2mW/cm
2
(1mW/cm
2
for Canada).
- Leakage for a fully assembled oven [Before the latch switch (primary) is
interrupted] while pulling the door ...... less than 2mW/cm
2
.
32
Summary of Contents for NN-S262SF APH
Page 4: ...reserved Unauthorized copying and distribution is a violation of law 2 ...
Page 5: ...3 ...
Page 6: ...4 ...
Page 7: ...5 ...
Page 9: ...3 CONTROL PANEL CPH 7 ...
Page 10: ...4 OPERATION AND DIGITAL PROGRAMMER CIRCUIT TEST PROCEDURE 4 1 To set clock 8 ...
Page 15: ...6 SCHEMATIC DIAGRAM CPH 13 ...
Page 36: ...13 TROUBLESHOOTING GUIDE 34 ...
Page 41: ...13 3 How to check the semiconductors using an OHM meter 14 EXPLODED VIEW AND PARTS LIST 39 ...
Page 49: ...20 DIGITAL PROGRAMMER CIRCUIT SCHEMATIC DIAGRAM 47 ...