background image

Matsushita

Programmable Controller FP-e

48 mm

Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: [email protected]

Summary of Contents for Network Adaptor

Page 1: ...Matsushita Programmable Controller FP e 48 mm Clearwater Tech Phone 800 894 0412 Fax 208 368 0415 Web www clrwtr com Email info clrwtr com ...

Page 2: ... well as timer counter settings and elapsed values can also be displayed Built in operation switch Setting values can be changed The operation switch can also be used as an input Panel mounted type in accordance with IP66 IEC standard To match panel design a black faceplate is available Matches FP0 intelligence equivalent to FP0 C14 Compact Panel mountable little space is taken up on the control p...

Page 3: ...ut Feeder roller Lead wire and tape Cutter Encoder Motor START STOP signal Inverter Cutter blade control signal Input encoder output into the high speed counter Equipped with RS485 and RS232C interfaces Two point K type thermocouple 30 to 300 C connection is possible equipped with thermocouple input Can be used in place of a temperature controller or used to control them PID instruction function H...

Page 4: ...PROG MODE 1 2 SET 5 4 3 2 1 0 FP e I PROG MODE 1 2 SET 5 4 3 2 1 0 FP e PV R PROG MODE 1 2 SET 5 4 3 2 1 0 FP e Features 1 5 character 2 line 3 color Display Simple characters and numerical values can be displayed Simple error messages as well as operation instructions and timer counter set values can be displayed 2 Front Operation Switch Timer Counter set values can be changed using front operati...

Page 5: ...n no power is supplied at all Not available Not available 6 points in total X0 and X1 50 µs X2 to X5 100 µs Programming method Control method Number of controllable I O points Program memory Program capacity Number of instruction Operation speed I O update and Base time Internal relay R Special internal relay R Timer Counter T C Data register DT Special data register DT Index registers IX IY Diffe...

Page 6: ... µs or less X0 X1 Note 1 100 µs or less X2 to X5 Note 1 2 ms or less X6 X7 LCD display I O monitor mode Thermocouple input specifications Item Number of input Temperature sensor type Input range Accuracy Resolution Conversion time Description 2 points CH0 WX1 CH1 WX2 Thermocouple type K 30 0 to 300 0 C 1 22 to 572 F 0 5 FS 1 5 C FS 30 to 300 C 0 1 C 250 ms 2CH 2 Insulation method Between internal ...

Page 7: ...rmat Stop bit 1 bit 2 bit Parity Not available Available Odd number Even number Data length 7 bit 8 bit Beginning code STX available STX not available Ending code CR CR LF not available ETX Communication mode General purpose communication Computer link 99 5 6 Data output order No of connected units Starting from 0 bits per character Relay output specifications Y5 Item Output type Rated control cap...

Page 8: ...ebell Dublin 12 Republic of Ireland Tel 01 4600969 Fax 01 4601131 www matsushita ie Italy Matsushita Electric Works Italia s r l Via del Commercio 3 5 Z I Ferlina I 37012 Bussolengo VR Tel 045 6752711 Fax 045 6700444 www matsushita it Portugal Matsushita Electric Works España S A Portuguese Branch Office Avda 25 de Abril Edificio Alvorada 5 ºE 2750 512 Cascais Portugal Tel 21 4828266 Fax 21 482742...

Reviews: