background image

FP-e Control Units

Decisive advantages in its class

FP-e 

Control Unit

New Age, Advanced Controller!
Timer, Counter, Hour Meter, Temperature Controller and PLC in one Unit

 Display modes and functions

 Type

Name

FP-e 
control 
unit

Type

Product No.

Calendar

timer

Thermocouple

input

COM.

port

Standard type (RS232C)

Calendar timer type (RS232C)

Thermocouple input type (RS232C)

Standard type (RS485)

Thermocouple input type (RS485)

AFPE224300

AFPE224305

AFPE214325

AFPE224302

AFPE214322

RS232C

RS232C

RS232C

RS485

RS485

Not available

Available

Available

Not available

Not available

Not available

Not available

Available

Not available

Available

4

4

3

3

1

1

2

2

N mode

(Normal mode)

S mode

(Switch mode)

R mode

(Register mode)

I mode

(I/O monitor mode)

Displays characters and 
numerical values, numerical 
data can be changed.

Can also display characters and 
numerical values. Operation 
switches can be used as inputs.

Operation memory in the 
controller can be monitored 
and its data changed.

I/O status (X, Y) in the 
controller can be 
monitored.

N

PROG.

MODE

1/2/SET

5

4

3

2

1

0

FP-e

S

PROG.

MODE

1/2/SET

5

4

3

2

1

0

FP-e

I

PROG.

MODE

1/2/SET

5

4

3

2

1

0

FP-e

PV

R

PROG.

MODE

1/2/SET

5

4

3

2

1

0

FP-e

 Features

1. 5-character, 2-line, 3-color Display

Simple characters and numerical values 
can be displayed. Simple error messages 
as well as operation instructions and 
timer/counter set values can be 
displayed.

2. Front Operation Switch

Timer/Counter set values can be 
changed using front operation switches. 
The switches can also be used as input 
switches (X30 to X3F), so you need not 
install external switches.

3. Equivalent to FP0-C14 Intelligence 

of Small PLCs

In addition to the functions of 
programmable controller FP0, pulse 
output and high-speed counter functions 
can be used. The unit comes equipped 
with a tool port, and COM. port 
(RS232C/RS485) for communication.

4. Easy Programming Using Wizard

Screen display instructions can be easily 
created using a programming tool wizard 
in FPWIN GR Ver. 2.3. or FPWIN Pro 
Ver. 5.0.

5. Smooth Debugging

Monitoring memory area data and the I/O 
status facilitates debugging using the R 
(register) and I (I/O monitor) display 
modes.

6. Panel Mounted Type

The front of a unit is water-proof (in 
accordance with IP66, IEC standard).

Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: [email protected]

Summary of Contents for Network Adaptor

Page 1: ...Matsushita Programmable Controller FP e 48 mm Clearwater Tech Phone 800 894 0412 Fax 208 368 0415 Web www clrwtr com Email info clrwtr com ...

Page 2: ... well as timer counter settings and elapsed values can also be displayed Built in operation switch Setting values can be changed The operation switch can also be used as an input Panel mounted type in accordance with IP66 IEC standard To match panel design a black faceplate is available Matches FP0 intelligence equivalent to FP0 C14 Compact Panel mountable little space is taken up on the control p...

Page 3: ...ut Feeder roller Lead wire and tape Cutter Encoder Motor START STOP signal Inverter Cutter blade control signal Input encoder output into the high speed counter Equipped with RS485 and RS232C interfaces Two point K type thermocouple 30 to 300 C connection is possible equipped with thermocouple input Can be used in place of a temperature controller or used to control them PID instruction function H...

Page 4: ...PROG MODE 1 2 SET 5 4 3 2 1 0 FP e I PROG MODE 1 2 SET 5 4 3 2 1 0 FP e PV R PROG MODE 1 2 SET 5 4 3 2 1 0 FP e Features 1 5 character 2 line 3 color Display Simple characters and numerical values can be displayed Simple error messages as well as operation instructions and timer counter set values can be displayed 2 Front Operation Switch Timer Counter set values can be changed using front operati...

Page 5: ...n no power is supplied at all Not available Not available 6 points in total X0 and X1 50 µs X2 to X5 100 µs Programming method Control method Number of controllable I O points Program memory Program capacity Number of instruction Operation speed I O update and Base time Internal relay R Special internal relay R Timer Counter T C Data register DT Special data register DT Index registers IX IY Diffe...

Page 6: ... µs or less X0 X1 Note 1 100 µs or less X2 to X5 Note 1 2 ms or less X6 X7 LCD display I O monitor mode Thermocouple input specifications Item Number of input Temperature sensor type Input range Accuracy Resolution Conversion time Description 2 points CH0 WX1 CH1 WX2 Thermocouple type K 30 0 to 300 0 C 1 22 to 572 F 0 5 FS 1 5 C FS 30 to 300 C 0 1 C 250 ms 2CH 2 Insulation method Between internal ...

Page 7: ...rmat Stop bit 1 bit 2 bit Parity Not available Available Odd number Even number Data length 7 bit 8 bit Beginning code STX available STX not available Ending code CR CR LF not available ETX Communication mode General purpose communication Computer link 99 5 6 Data output order No of connected units Starting from 0 bits per character Relay output specifications Y5 Item Output type Rated control cap...

Page 8: ...ebell Dublin 12 Republic of Ireland Tel 01 4600969 Fax 01 4601131 www matsushita ie Italy Matsushita Electric Works Italia s r l Via del Commercio 3 5 Z I Ferlina I 37012 Bussolengo VR Tel 045 6752711 Fax 045 6700444 www matsushita it Portugal Matsushita Electric Works España S A Portuguese Branch Office Avda 25 de Abril Edificio Alvorada 5 ºE 2750 512 Cascais Portugal Tel 21 4828266 Fax 21 482742...

Reviews: