When the Circuit Breaker automatically stops the motor due to overloading, follow the below steps:
1
Switch off to reset the Circuit Breaker.
2
Reduce the ingredients to less than 1/2 of the working capacity and/or remove hard ingredients.
3
Resume blending. If the Circuit Breaker still activates, repeat step 1 - 2. Do not repeatedly reset the Circuit
Breaker.
Troubleshooting
Please check following points before arranging for service.
Ensure to turn off the appliance and the power supply before taking the actions in the table below:
Problems
Causes
Actions
The appliance does not turn on.
The Plug is not inserted into an outlet. Insert the Plug into an outlet.
Even though the power is on, the
appliance does not start blending.
The Blender Jug or the Mill Container
is not placed correctly.
Place the Blender Jug or the Mill Container
correctly.
Overloaded with ingredients or
prohibited ingredients are used.
Do not exceed the working capacity of the
ingredients and ensure that prohibited ingredients
are not used.
The Safety Lever is stuck.
Disassemble the Blender Jug Base and follow the
assembly sequence (page
EN5
).
The appliance stops during blending.
The Circuit Breaker Protection is
activated.
•
Too many ingredients or hard
ingredients are used.
See "Circuit Breaker Protection".
Prohibited ingredients are used.
Remove prohibited ingredients.
Maximum operating time is exceeded.
Turn off the appliance and refer to the
recommended operating time (page
EN3
).
The mixture in the Blender Jug is
leaking.
The Blender Jug Base is attached
loosely.
Tighten the Blender Jug Base fi rmly onto the
Blender Jug.
The Blender Gasket is not installed
correctly.
Install the Blender Gasket correctly.
The Blender Gasket is not installed.
Install the Blender Gasket.
The Safety Lever is stuck.
Disassemble the Blender Jug Base and follow the
assembly sequence (page
EN5
).
There is abnormal noise or vibration.
Too many ingredients in the Blender
Jug.
Turn off the appliance and reduce the ingredients.
The Blender Jug Base is attached
loosely.
Tighten the Blender Jug Base fi rmly onto the
Blender Jug.
The Cutting Blades is spinning freely
without cutting.
Ingredients are stuck to the wall of the
Blender Jug.
Turn off the appliance and insert the Scraper to
circulate.
Quantity of the liquid is low.
Add liquid.
• Lubrication oil might be traced on the Lower Connector but it will not affect the performance. Please wipe it.