No.SX-DSV01676
- 21 -
R2
Motor Company, Matsushita Electric Industrial Co., Ltd.
7-4 RS232 communication connector X4 (JST MD-S8000-10 or equivalent)
You can make a RS232 communication with a personal computer or the handy console, and
make operations such as setup/change of parameters, monitoring of control status, reference
of error status and history and saving/loading of parameters and so on.
This drive supports the setup support software “PANATERM”, and its communication cable
as options.
For the operation of the “PANATERM”, refer to its instruction manual.
·PANATERM(WIN98/NT/2000/XP)
DV0P4460
·Connection cable to PC (DOS/V
)
DV0P1960
·Console
DV0P4420
7-5 Network connectors X3A X3B (Molex 85505-0013 or equivalent)
RJ45 Connector for network interface
[X3A] RX connector
Name Pin
No.
Description
Unused
1
-
Connect to Pin-1 of TX connector of node at transmitter side.
Unused
2
-
Connect to Pin-2 of TX connector of node at transmitter side.
Network input +
3
RX+ Connect to Pin-3 of TX connector of node at transmitter side.
Unused
4
-
Connect to Pin-4 of TX connector of node at transmitter side.
Unused
5
-
Connect to Pin-5 of TX connector of node at transmitter side.
Network input -
6
RX-
Connect to Pin-6 of TX connector of node at transmitter side.
Unused
7
-
Connect to Pin-7 of TX connector of node at transmitter side.
Unused
8
-
Connect to Pin-8 of TX connector of node at transmitter side.
Frame ground
Shell
FG
Connect to the shield of the cable.
[X3B] TX connector
Name Pin
№
Description
Unused 1
-
Connect to Pin-1 of RX connector of node at reception side.
Unused 2
-
Connect to Pin-2 of RX connector of node at reception side.
Network input +
3
TX+
Connect to Pin-3 of RX connector of node at reception side.
Unused 4
-
Connect to Pin-4 of RX connector of node at reception side.
Unused
5
-
Connect to Pin-5 of RX connector of node at reception side.
Network input -
6
TX-
Connect to Pin-6 of RX connector of node at reception side.
Unused 7
-
Connect to Pin-7 of RX connector of node at reception side.
Unused 8
-
Connect to Pin-8 of RX connector of node at reception side.
Frame ground
Shell
FG
Connect to the shield of the cable.
* Use the shielded twisted pair (STP) cable of category 5e or better specified in TIA/EIA-568 without fail.
Category 6 or better is recommended.
(Note) Use the cable with 8-wire (4 pair), “straight” connection
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]