4.1. Lower Plate
4.1.1. Removal
1. Place handle in low position.
2. Turn the vacuum cleaner over exposing the underside.
Release the lower plate by pressing the two (2) latches that
secure it inward.
3. Separate the lower plate from the vacuum.
4.1.2. Installation
1. Hook the front of the lower plate into the slots on the front
of the nozzle housing. Press the lower plate down into
place.
2. Fasten the lower plate by pushing the two (2) latches
outward.
NOTE: For general servicing, it is necessary to eliminate
pinching of any wire during reassembly. After servicing any
electrical component or enclosure, the unit should be
reassembled and checked for dielectric breakdown or
current leakage.
4.2. Agitator Assembly
4.2.1. Removal
1. The brushes are not replaceable separately. When the
brushes need replacing, the agitator assembly will have to
be replaced.
2. Remove the lower plate as outline in Lower Plate removal /
installation section.
3. Carefully lift up on the agitator assembly until it clears both
sides of the nozzle housing.
4. Remove the belt from the motor shaft by sliding it off
between the end of the shaft and the nozzle housing.
4.2.2. Installation
1. Place the belt around the motor shaft.
4 SERVICE PROCEDURES - NOZZLE
12
MC-GG523-00