4 Disassembly and Assembly Instructions

IMPORTANT: Before replacing any part always DISCONNECT THE CLEANER FROM THE ELECTRICITY SUPPLY.

4.1.

BELT (Beater bar belt), BELT B
(Motor shaft belt)

1. Loosen 5 screws from the base plate (Floor nozzle lower

unit) and remove it. (Fig. 1)

2. Remove the beater bar unit from the floor nozzle upper

unit. (Fig. 2)

3. Remove the 1 screw from the pedal shaft to detach the

pedal. (Fig. 3)

4. Pull out the pedal shaft slightly. Remove the tip of the

shaft from the metal plated of the idler pulley. Then
remove it together with the pedal.

5. Remove belt B from the motor shaft and then from the

idler pulley.

6. Remove the belt from the beater bar unit and then from

the idler pulley.

7. Fit a new belt and belt B by reversing the disassembly

procedure. Fit the belt first, then belt B.

Summary of Contents for MC-E3002-WP47

Page 1: ...nd Components 3 3 Troubleshooting Guide 5 4 Disassembly and Assembly Instructions 6 4 1 BELT Beater bar belt BELT B Motor shaft belt 6 4 2 BEATER BAR UNIT 7 4 3 IDLER PULLEY UNlT 7 4 4 FAN MOTOR UNIT 8 4 5 PC board w component ON OFF Switch Fuse unit and Power cord Mains lead 9 4 6 ON OFF SWITCH 11 5 Wiring Connection Diagram 11 6 Exploded View and Replacement Parts List 12 6 1 EXPLODED VIEW BODY ...

Page 2: ...out notice for further improvement Model MC E3002 WP47 Power source AC230 240V 50Hz Input power MAX 1900W Input power Nominal 1600 1700W Cord length 6 7m Net weight 6 3kg Dimensions L x W x H mm 320 x 323 x 1045 Dusting brush O Crevice nozzle O Extension wand O ...

Page 3: ...3 2 Location of Controls and Components ...

Page 4: ...4 ...

Page 5: ...r connector pipe Check whether or not the hose or connector pipe has been clogged with dust If they are clogged with dust then remove the dust There is abnormal noise or vibra tion Fan motor unit Check whether or not dust has entered the fan motor unit the dust bag whether or not the dust bag has broken If dust has entered the fan motor then replace the fan motor unit Check the dust bag and replac...

Page 6: ...it from the floor nozzle upper unit Fig 2 3 Remove the 1 screw from the pedal shaft to detach the pedal Fig 3 4 Pull out the pedal shaft slightly Remove the tip of the shaft from the metal plated of the idler pulley Then remove it together with the pedal 5 Remove belt B from the motor shaft and then from the idler pulley 6 Remove the belt from the beater bar unit and then from the idler pulley 7 F...

Page 7: ...te the beater bar unit by hand and check that it is fitted properly 5 Replace the base plate Floor nozzle lower unit and refasten screw 4 3 IDLER PULLEY UNlT 1 Remove the base plate Floor nozzle lower unit 2 Remove 1 screw from the pedal and take it out Fig 5 3 Release the two belts from the Idler pulley 4 Remove 2 screws from the Idler pulley unit and take it out Fig 6 5 Replace the Idler pulley ...

Page 8: ...nect the hose and connector pipe from the floor nozzle upper unit Fig 7 3 Insert a flat head screwdriver between nozzle housing and the plastic holder then pry out the plastic holder Fig 8 4 Turn the vacuum cleaner over and remove 4 screws from Moter case and take it out Fig 9 Connection of Connector A unit during assembly Connect Connector A unit as shown in Fig 10 ...

Page 9: ... lead wires to the motor 8 Re install the motor and reassemble motor case and remaining parts in the reverse order NOTE Make sure the lead wires are correctly posi tioned to avoid pinching them between parts Connection of Connector A unit during assembly Connect Connector A unit as shown in Fig 13 so that the unit is inserted in the cut of the noise absorber 4 5 PC board w component ON OFF Switch ...

Page 10: ... the P C B holder Remove the PC board w Components inside Fig 17 Note You can remove the ON OFF switch fuse unit and mains power cord lead wire 5 Connect the lead wires according to the schematic dia gram restore the switch cover to its original position and refasten the screws Connection of the lead wires for assembly Connect the lead wires as shown in Fig 15 ...

Page 11: ...d lead wire 4 6 1 2 Remove the two lead wires from the ON OFF switch with fast on terminal Fig 18 3 Replace the ON OFF switch with a new one Connect the two lead wires to the terminal according to the schematic diagram 4 Restore the switch cover to its original position and refas ten the screws 5 Wiring Connection Diagram MODEL MC E3002 WP47 ...

Page 12: ...DY UNIT 1 3 2 9 9 8 10 11 12 13 14 15 78 21 22 16 17 6 5 4 23 31 27 28 29 77 20 33 37 79 34 79 32 30 38 39 18 19 24 25 43 23 72 44 43 17 17 26 44 72 42 45 35 36 79 40 79 79 55 54 76 41 53 51 46 47 49 50 52 79 65 79 58 56 57 66 69 68 63 61 62 61 64 79 79 68 69 75 74 73 ...

Page 13: ...king 1 34 AMC32K XB0KE Filter suppoter 1 35 AMC42K XA06E Filter case 1 36 AMC38K XA00E Exhaust filter 1 37 AMV92L 580WE Dust box lid unit 1 Dust bag Cover 38 AMC B1EP Dust bag Type U 20E 1 pack of 5 bags Type U 20E 39 AMC19F XB00E Motor case rubber 1 40 AMC93F ZS0WE Motor cover unit 1 41 AMC30L XB00E Outlet filter 1 42 AMC16C XB00E Roller shaft 1 43 AMC01C XD04E Wheel 2 44 XUB7FP Fixing washer 2 4...

Page 14: ...14 79 XTN4 18BFJ Tapping screw 16 Safety Ref No PART NO PART NAME DESCRIPTION Q TY Remarks ...

Page 15: ...y Ref No PART NO PART NAME DESCRIPTION Q TY Remarks 1 AMV01Z 58008 Operating Instructions 1 2 AMC69Z ZS00E Cushion A 1 3 AMC70Z XB00E Cushion B 1 4 AMC0TZ XB00E Cushion C 1 5 AMV61Z 5800E Individual carton 1 6 AMC72Z XB00E Cushion plate A 1 1 2 4 6 5 3 ...

Reviews: