background image

Schottky Barrier Diodes (SBD)

1

Publication date: April 2004

SKH00015BED

MA2J729 

(MA729)

Silicon epitaxial planar type

For super high speed switching

For small current rectification

Features

Forward current (Average) I

F(AV)

 

=

 200 mA rectification is

possible

High-density mounting is possible

Absolute Maximum Ratings  

T

a

 

=

 

25

°

C

Parameter

Symbol

Rating

Unit

Reverse voltage

V

R

30

V

Repetitive peak reverse voltage

V

RRM

30

V

Peak forward current

I

FM

300

mA

Forward current (Average)

I

F(AV)

200

mA

Non-repetitive peak forward

I

FSM

1

A

surge current 

*

Junction temperature

T

j

150

°

C

Storage temperature

T

stg

55 to

 +

150

°

C

Parameter

Symbol

Conditions

Min

Typ

Max

Unit

Forward voltage

V

F

I

F

 

=

 200 mA

0.55

V

Reverse current

I

R

V

R

 

=

 30 V

50

µ

A

Terminal capacitance

C

t

V

R

 

=

 0 V, f 

=

 1 MHz

30

pF

Reverse recovery time 

*

t

rr

I

F

 

=

 I

R

 

=

 100 mA

3.0

ns

I

rr

 

=

 0.1 I

R

,  R

L

 

=

 100 

Electrical Characteristics

  T

a

 

=

 

25

°

±

 3

°

C

Marking Symbol: 2B

Bias Application Unit (N-50BU)

90%

Pulse Generator
(PG-10N)
R

s

 

50 

Wave Form Analyzer
(SAS-8130)
R

i

 

50 

t

p

 

µ

s

t

r

 

0.35 ns

δ = 

0.05

I

F

 

=

 100 mA

I

R

 

=

 100 mA

R

L

 

=

 100 

10%

Input Pulse

Output Pulse

I

rr

 

=

 0.1 I

R

t

r

t

p

t

rr

V

R

I

F

t

t

A

Unit: mm

1: Anode
2: Cathode
EIAJ: SC-76

SMini2-F1 Package

1.25

±

0.1

0.7

±

0.1

2.5

±

0.2

1.7

±

0.1

0.4

±

0.1

0 to 0.1

(0.15)

0.16

0.5

±

0.1

1

2

+0.1

–0.06

0.35

±

0.1

0 to 0.1

Note) *: The peak-to-peak value in one cycle of 50 Hz sine wave (non-repetitive)

Note) 1. Measuring methods are based on JAPANESE INDUSTRIAL STANDARD JIS C 7031 measuring methods for diodes.

2. This product is sensitive to electric shock (static electricity, etc.). Due attention must be paid on the charge of a human body

and the leakage of current from the operating equipment.

3. Absolute frequency of input and output is 1 GHz.

4. *: t

rr

 measurement circuit

Note) The part number in the parenthesis shows conventional part number.

This product complies with the RoHS Directive (EU 2002/95/EC).