26
8.3.7.
MeShut(LV13/LV14) Calibration
1. Setting the DSC
1. Set the battery to the camera.
2. Turn off the power.
3. Press "Tele" + "Menu/Set" + "Playback" key at the same time. It starts in the state of "Engineer Mode" automatically.
4. Press "Playback" key to enter selection menu.
5. To Select the Light box mode, carry out the following operations.
a. Press "Right Key" or "Left Key" to change selected item to "
WB/AGC(LV10)
", and press "PLAYBACK Key".
b. Press "UP Key" or "Down Key" to change selected item to "Light Src", and press "Right Key" or "Left Key" to set the value
as "00002", and press "MENU/SET Key".
6. Set the DSC to the front of light box closely less than 5mm.
2. Execute Calibration
1. Press "Right Key" or "Left Key" or "Up Key" or "Down Key" to change selected item.
2. Choose "
MeShut26(LV13)
", and press "Display Key".
3. Change the flag status of "Disable" from 00001 to 00000 by operating "Right Key" or "Left Key", and then press "Menu/Set
Key".
4. Press "Menu/Set Key" again, and select "OK", and press "Menu/Set Key" to start checking.
5. When calibration finishes, the screen will show the result "OK" or "NG".
6. Choose "
MeShut80(LV14)
", and operate and execute calibration same as "MeShut26".
7. Press "PLAYBACK Key" to return to calibration menu.
8.3.8.
Dark DP Calibration
1. Setting the DSC
1. Set the battery to the camera.
2. Turn off the power.
3. Press "Tele" + "Menu/Set" + "Playback" key at the same time. It starts in the state of "Engineer Mode" automatically.
4. Press "Playback" key to enter selection menu.
5. Set the DSC to the front of Light Box closely less than 5mm.
* The "Light box mode" is not depend on the calibration result.
2. Execute Calibration
1. Press "Right Key" or "Left Key" or "Up Key" or "Down Key" to change selected item.
2. Choose "
Dark DPC
", and press "Display Key".
3. Change the flag status of "Disable" from 00001 to 00000 by operating "Right Key" or "Left Key", and then press "Menu/Set
Key".
4. Press "Menu/Set Key" again, and select "OK", and press "Menu/Set Key" to start checking.
5. When calibration finishes, the screen will show the result "OK" or "NG".
6. Press "PLAYBACK Key" to return to calibration menu.
* It takes several minutes.