LC2H
Applicable standard
Safety standard
EN61010-1
Pollution Degree 2/Overvoltage Category III
EMC
(EMI)EN61000-6-4
Radiation interference electric field strength
Noise terminal voltage
(EMS)EN61000-6-2
Static discharge immunity
RF electromagnetic field immunity
EFT/B immunity
Conductivity noise immunity
Power frequency magnetic field immunity
EN55011 Group1 ClassA
EN55011 Group1 ClassA
EN61000-4-2 4 kV contact
8 kV air
EN61000-4-3 10 V/m AM modulation (80 MHz to 1 GHz)
10 V/m pulse modulation (895 MHz to 905 MHz)
EN61000-4-4 2 kV (power supply line)
EN61000-4-6 10 V/m AM modulation (0.15 MHz to 80 MHz)
EN61000-4-8 30 A/m (50 Hz)
2. PC board mounting type
3. Common
Type
Item
PC board mounting type
Input method
Non DC voltage input
No. digits
8 digits
Rated operation voltage
3 V DC
Allowable operation voltage range
2.7 to 3.3 V DC
Current consumption
Max. 30 µA (max. 250 µA during reset input)
Max. counting speed
2 kHz
30 Hz
Count
input
Min. input signal width
(ON: OFF = 1:1)
0.25 ms
16.7 ms
Input method
Non-voltage input using contacts or open collector connection
Input impedance
When shorted: Max. 10 k
Ω
When open: Max. 750 k
Ω
Residual voltage
Max. 0.5 V
Reset
input
Min. input signal width
10 ms
Input method
Non-voltage input using contacts or open collector connection
Input impedance
When shorted: Max. 10 k
Ω
When open: Max. 750 k
Ω
Residual power
Max. 0.5 V
Break down voltage (initial)
Between charged and uncharged parts: 1,000 V AC for 1 minute.
Insulation resistance (initial)
Min. 100 M
Ω
(measured at 500 V DC) Measurement location same as for break down voltage.
Type
Item
Panel mounting/PC board mounting types
Vibration resistance
Functional
10 to 55 Hz (1 cycle/min.), single amplitude: 0.15 mm
.006 inch
(10 min. on 3 axes)
Destructive
10 to 55 Hz (1 cycle/min.), single amplitude: 0.375 mm
.015 inch
(1 hr. on 3 axes)
Shock resistance
Functional
Min. 98 m/s
2
(4 times on 3 axes)
Destructive
Min. 294 m/s
2
(5 times on 3 axes)
Operation temperature
–10 to +55°C
+14 to +131°F
(without frost or dew)
Storage temperature
–25 to +65°C
–13 to +149°F
(without frost or dew)
Ambient humidity
35 to 85% RH (non-condensing)
CTi Automation - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - Email: [email protected]