Frequently Used Items (Base Unit)
ex.)
Note:
(*1) Refer to
Registering a Handset to the Base Unit
(P.21)
(*2) When you enter the address or New Data, please refer to the table below.
(*3)
(*4)
(*5) The new data must be entered in all three addresses (01 F6, 03 8A, 03 8B) using the same value.
Ex.) If you want to change the bell length to “1E (3 sec)”.
01 F6 - 1E
03 8A - 1E
03 8B - 1E
Items
(*3)
Address
Default Data
New Data
Remarks
C-ID (FSK) sensitivity
04 72
00
01 (6dB up)
02 (12dB up) When hex changes from “00” to “01” or “02”,
gain increases by 6dB or 12dB.
C-ID (DTMF) sensitivity
04 80
50
60 (6dB up)
70 (12dB up) When hex changes from “50” to “60” or “70”,
gain increases by 6dB or 12dB.
SMS (FSK) receiving sensitiv-
ity
04 72
00
01 (6dB up)
02 (12dB up) When hex changes from “00” to “01” or “02”,
gain increases by 6dB or 12dB.
SMS (FSK) sending level
04 8C/04 8B
0x12/0x28
19/20 (6dB up) 32/40 (12dB
up)
When hex changes from “00 0B” to “00 16” or
“00 2C”, gain increases by 6dB or 12dB.
Frequency
00 01
75
-
-
Use these items in a
READ-ONLY
mode to
confirm the contents. Careless rewriting may
cause serious damage to the computer system.
ID
00 10~00 14
Given value
-
-
Bell length
01 F6
03 8D
03 8E
64 (10sec) (*4)
32 (5sec)
64 (10sec)
1E (3sec) (*5)
14 (2sec)
This is time until bell stops ringing.
(Unit: 100ms)
PULSE Dial speed
(10PPS -> 20PPS)
03 5F
03 61
2A (40msec)
(*4)
16 (20msec)
-
This is pulse make time. (Unit:1ms)
03 60
03 62
3A (60msec)
(*4)
1C(30msec)
-
This is pulse break time. (Unit:1ms)
01 E4
57 (870msec)
(*4)
2C (440msec)
-
This is inter-digit time in pulse mode.
(Unit:10ms)
Desired Number (hex)
Input Keys
Desired Number (hex)
Input Keys
0
0
A
[R] + 0
1
1
B
[R] + 1
.
.
C
[R] + 2
.
.
D
[R] + 3
.
.
E
[R] + 4
9
9
F
[R] + 5
Items
Description
C-ID (FSK) sensitivity
FSKGain_shiftgain
C-ID (DTMF) sensitivity
Foutgains:HPFilter Foutgains
SMS (FSK) receiving sensitivity
FSKGain_shiftgain
SMS (FSK) sending level
wFskAttn:Signal Output Attenuation (DSP parameter)
Frequency
Setting value of FREQ_TRIM_REG
ID
ID
Bell length
Time until it stops bell.
PULSE Dial speed
(10PPS -> 20PPS)
Pulse MakeTime and BreakTime.
bMakeTime:Pulse MakeTime Unit: 1ms
bBreakTime:Pulse Break Time Unit: 1ms
Inter-digit time in Pulse mode.
Unit:10ms
Bell length
64(hex) = 100(dec)
→
100
×
100msec = 10000msec (10sec)
PULSE Dial speed
(10PPS -> 20PPS)
2A(hex) = 42(dec)
→
(42-2)
×
1msec = 40msec
3A(hex) = 58(dec)
→
(58+2)
×
1msec = 60msec
57(hex) = 87(dec)
→
87
×
10msec = 870msec
Summary of Contents for KX-TG7120FXT
Page 2: ...2 KX TG7120BXS KX TG7120BXT KX TGA711CXS KX TGA711CXT ...
Page 14: ...14 KX TG7120BXS KX TG7120BXT KX TGA711CXS KX TGA711CXT 4 6 Signal Route ...
Page 15: ...15 KX TG7120BXS KX TG7120BXT KX TGA711CXS KX TGA711CXT ...
Page 22: ...22 KX TG7120BXS KX TG7120BXT KX TGA711CXS KX TGA711CXT 7 4 For Service Hint ...
Page 25: ...25 KX TG7120BXS KX TG7120BXT KX TGA711CXS KX TGA711CXT 8 1 2 Handset ...
Page 48: ...48 KX TG7120BXS KX TG7120BXT KX TGA711CXS KX TGA711CXT 10 1 2 Handset ...
Page 49: ...49 KX TG7120BXS KX TG7120BXT KX TGA711CXS KX TGA711CXT 10 1 3 Charger Unit ...
Page 50: ...50 KX TG7120BXS KX TG7120BXT KX TGA711CXS KX TGA711CXT 10 2 How to Replace the Handset LCD ...
Page 65: ...65 KX TG7120BXS KX TG7120BXT KX TGA711CXS KX TGA711CXT Memo ...
Page 85: ...85 KX TG7120BXS KX TG7120BXT KX TGA711CXS KX TGA711CXT 15 4 2 KX TGA711FXS FXT ...