38
KX-TG7120BXS/KX-TG7120BXT/KX-TGA711CXS/KX-TGA711CXT
(
M
)
Sensitivity Receiver
Confirmation
-
Follow steps 1 to 6 of
(I)
.
7.Set DECT tester power to -90 dBm.
8.Confirm that the BER is < 1000 ppm.
IC7, IC10, L7,
L3, L4, L6,
C117, C118,
C119, C120,
C124, C125,
R106, R109,
DA1, C102,
R102, R103,
Q10, C110,
C112, R111,
C126, C127,
R112
(
N
)
Timing Confirmation
-
Follow steps 1 to 6 of
(I)
.
7.Confirm that the Timing accuracy is < ± 2.0 ppm.
IC7, IC10, L7,
L3, L4, L6,
C117, C118,
C119, C120,
C124, C125,
R106, R109,
DA1, C102,
R102, R103,
Q10, C110,
C112, R111,
C126, C127,
R112
(
O
)* RSSI Level Confirmation
-
Follow steps 1 to 6 of
(I)
.
7.Execute the command “readrssi”.
8. Confirm that the returned value is 22 ± A (hex).
IC7, IC10, L7,
L3, L4, L6,
C117, C118,
C119, C120,
C124, C125,
R106, R109,
DA1, C102,
R102, R103,
Q10, C110,
C112, R111,
C126, C127,
R112
(
P
) Power RAMP Confirma-
tion
-
Follow steps 1 to 6 of
(I)
.
7.Confirm that Power RAMP is matching.
IC7, IC10, L7,
L3, L4, L6,
C117, C118,
C119, C120,
C124, C125,
R106, R109,
DA1, C102,
R102, R103,
Q10, C110,
C112, R111,
C126, C127,
R112
(
Q
)*
Audio Check
-
1. Link with Handset.
2. Input -45dBm/1kHz to MIC of Handset.
Measure the Level at Line I/F and distortion level.
3. Confirm that the level is -8.5 dBm ± 2 dBm and that the distortion level is < 5%
at TEL Line (600
Ω
Load).
4. Input -20 dBm/1 kHz to Line I/F.
Measure the level at Receiver of Handset and distortion level
(*Receive volume set to second position from minimum).
5. Confirm that the level is -21 dBm ± 2 dBm and that the distortion level is < 5%
at Receiver (Volume Middle, 150
Ω
Load).
IC7, CN1, SA1,
L1, L2, D3, Q3,
Q4, R14, R15,
R16, R17
(
R
)
Charging Check
-
1. Connect Charge Contact 12
Ω
/2 W resistor between and charge-.
2. Measure and confirm voltage across the resistor is 3.10 V ± 0.2 V.
R55, R56, C48,
C49
(
S
)
TAM Operation
Confirmation
-
1. TAM Confirmation (Execute the command “sendchar_VPI”)
2. Confirm the returned Value (Value is “D897FN”).
IC8, IC9, R89,
R91, R92
Items
Check
Point
Procedure
Check or
Replace Parts
Summary of Contents for KX-TG7120FXT
Page 2: ...2 KX TG7120BXS KX TG7120BXT KX TGA711CXS KX TGA711CXT ...
Page 14: ...14 KX TG7120BXS KX TG7120BXT KX TGA711CXS KX TGA711CXT 4 6 Signal Route ...
Page 15: ...15 KX TG7120BXS KX TG7120BXT KX TGA711CXS KX TGA711CXT ...
Page 22: ...22 KX TG7120BXS KX TG7120BXT KX TGA711CXS KX TGA711CXT 7 4 For Service Hint ...
Page 25: ...25 KX TG7120BXS KX TG7120BXT KX TGA711CXS KX TGA711CXT 8 1 2 Handset ...
Page 48: ...48 KX TG7120BXS KX TG7120BXT KX TGA711CXS KX TGA711CXT 10 1 2 Handset ...
Page 49: ...49 KX TG7120BXS KX TG7120BXT KX TGA711CXS KX TGA711CXT 10 1 3 Charger Unit ...
Page 50: ...50 KX TG7120BXS KX TG7120BXT KX TGA711CXS KX TGA711CXT 10 2 How to Replace the Handset LCD ...
Page 65: ...65 KX TG7120BXS KX TG7120BXT KX TGA711CXS KX TGA711CXT Memo ...
Page 85: ...85 KX TG7120BXS KX TG7120BXT KX TGA711CXS KX TGA711CXT 15 4 2 KX TGA711FXS FXT ...