49
KX-TG7100FXS/KX-TG7100FXT/KX-TG7102FXS/KX-TGA711FXS/KX-TGA711FXT
11.3. Adjustment Standard (Charger Unit)
When connecting the Simulator Equipments for checking, please refer to below.
11.3.1.
Flow Solder Side View
Note:
(
A
) is referred to
Check Point (Charger Unit)
(P.36)
PQUP11413Z
for_ PQLV30045ZA
BLACK
RED
TP4
TP3
A
TP1
TP2
1
2
PbF
GND (TP4)
TP3
TP1
DC POWER
6.5V
Digital
Volt
Meter
12
Ω
/2W
GND (TP2)
(
A
)