52
KX-TG1061M/KX-TG1062M/KX-TGA106M
(
I
)* Hookswitch Check with
DC Characteristics
-
1. Connect TIP/RING (Telephone Socket) to Tel-simulator which is connected
with 600
Ω
.
2. Set line voltage to 48 V and line current to 40 mA at off-hook condition of nor-
mal telephone.
3. Execute the command “hookoff”
4. Confirm that the line current is 40 mA ± 5 mA.
5. Execute the command “hookon”.
6. Confirm that the line current is less than + 0.8 mA.
P101,D101,
Q111,Q112,
R110,R111,
R112,R123,
R115,R117,
R118,D117
(
J
) DTMF Generator Check
-
1. Connect TIP/RING (Telephone Socket) to DTMF tester. (Road=600
Ω
)
2. Link cordless handset and push dial key.
3. Confirm DTMF character.
4. Confirm that the high Group is -6 dBm ± 2 dBm.
5. Confirm that the low Group is -8 dBm ± 2 dBm.
IC501,R154,
R153,C151,
Q131
(
K
)* Transmitted Power Con-
firmation
ANT2
Remove the Antenna before starting step from 1 to 7.
1. Configure the DECT tester (CMD60) as follows;
<Setting>
• Test mode: FP
• Traffic Carrier: 2
• Traffic Slot: 4
• Mode: Loopback
• PMID: 00000
• RF LEVEL = -70 dBm.
2. Execute the command “testmode”.
3. Execute the command “sendchar dmv 2 2”.
4. Check that “Signalling Status” has been set to “Locked”, then press “ACCEPT
RFPI”.
5. Initiate connection from Dect tester (“set up connect”)
6. Execute the command “ANT2”.
7. Confirm that the NTP value at ANT is 16.5 dBm ~ 20.5 dBm.
DA802,C859,
C803,DA801,
C812,L802,
IC801,IC501
(
L
)*
Modulation Check
ANT2
Follow steps 1 to 6 of
(K)
.
7.Confirm that the B-Field Modulation is -430 ~ -350/+350 ~ +430 kHz/div using
data type Fig31.
DA802,C859,
C803,DA801,
C812,L802,
IC801,IC501
(
M
)* Frequency Offset Check
ANT2
Follow steps 1 to 6 of
(K)
.
7.Confirm that the frequency offset is < ± 10 kHz.
DA802,C859,
C803,DA801,
C812,L802,
IC801,IC501
(
N
)* Frequency Dirft Confir-
mation
ANT2
Follow steps 1 to 6 of
(K)
.
7.Confirm that the frequency drift is < ± 20 kHz/ms.
C803,DA801,
C812,L802,
IC801,IC501
(
O
)*
Sensitivity Receiver
Confirmation
ANT2
Follow steps 1 to 6 of
(K)
.
7.Set DECT tester power to -88 dBm.
8.Confirm that the BER is < 1000 ppm.
DA802,C859,
C803,DA801,
C826,R807,
C822,IC501
(
P
)*
Timing Confirmation
ANT2
(Through Cordless handset)
Follow steps 1 to 6 of
(K)
.
7.Confirm that the Timing accuracy is < ± 2.0 ppm.
DA802,C859,
C803,DA801,
C812,L802,
IC801,IC501
(
Q
)* RSSI Level Confirmation
ANT2
Follow steps 1 to 6 of
(K)
.
7.Execute the command “readrssi”.
8. Confirm that the returned value is 22 ± A (hex).
DA802,C859,
C803,DA801,
C826,R807,
C822,IC501
Items
Check
Point
Procedure
Check or
Replace Parts
Summary of Contents for KX-TG1061M - Cordless Phone Base Station
Page 2: ...2 KX TG1061M KX TG1062M KX TGA106M ...
Page 16: ...16 KX TG1061M KX TG1062M KX TGA106M 4 7 Signal Route ...
Page 17: ...17 KX TG1061M KX TG1062M KX TGA106M ...
Page 18: ...18 KX TG1061M KX TG1062M KX TGA106M ...
Page 23: ...23 KX TG1061M KX TG1062M KX TGA106M ...
Page 24: ...24 KX TG1061M KX TG1062M KX TGA106M 7 1 2 Programming using the Direct Commands ...
Page 25: ...25 KX TG1061M KX TG1062M KX TGA106M ...
Page 26: ...26 KX TG1061M KX TG1062M KX TGA106M 7 1 3 Answering System Settings ...
Page 28: ...28 KX TG1061M KX TG1062M KX TGA106M 7 4 Dialing Mode 7 5 Error Messages ...
Page 30: ...30 KX TG1061M KX TG1062M KX TGA106M ...
Page 31: ...31 KX TG1061M KX TG1062M KX TGA106M ...
Page 32: ...32 KX TG1061M KX TG1062M KX TGA106M 8 Service Mode 8 1 Engineering Mode 8 1 1 Base Unit ...
Page 34: ...34 KX TG1061M KX TG1062M KX TGA106M 8 1 2 Cordless Handset ...
Page 43: ...43 KX TG1061M KX TG1062M KX TGA106M Cross Reference Check Point Base Unit P 51 ...
Page 45: ...45 KX TG1061M KX TG1062M KX TGA106M Cross Reference Check Point Cordless Handset P 55 ...
Page 60: ...60 KX TG1061M KX TG1062M KX TGA106M ...
Page 61: ...61 KX TG1061M KX TG1062M KX TGA106M 10 1 2 Cordless Handset ...
Page 62: ...62 KX TG1061M KX TG1062M KX TGA106M 10 1 3 Charger Unit ...
Page 64: ...64 KX TG1061M KX TG1062M KX TGA106M 10 2 2 How to Replace the Cordless Handset LCD ...
Page 104: ...104 KX TG1061M KX TG1062M KX TGA106M 15 3 Cabinet and Electrical Parts Charger Unit ...
Page 105: ...105 KX TG1061M KX TG1062M KX TGA106M 15 4 Accessories and Packing Materials 15 4 1 KX TG1061M ...
Page 106: ...106 KX TG1061M KX TG1062M KX TGA106M 15 4 2 KX TG1062M ...
Page 107: ...107 KX TG1061M KX TG1062M KX TGA106M 15 4 3 KX TGA106M ...
Page 114: ...114 KX TG1061M KX TG1062M KX TGA106M Y S N KXTG1061M KXTG1062M KXTGA106M ...