51
KX-TG1061M/KX-TG1062M/KX-TGA106M
9.2.
Troubleshooting by Symptom (Base Unit and Charger Unit)
If your unit has below symptoms, follow the instructions in remedy column. Remedies depend on wether you have DECT tester
(*1) or not.
Note:
(*1) A general repair is possible even if you don’t have the DECT tester because it is for confirming the levels, such as Acoustic
level in detail.
(*2) Refer to
Check Point (Base Unit)
(P.51)
9.2.1.
Check Point (Base Unit)
Please follow the items below when BBIC, EEPROM or FLASH is replaced.
Note:
After the measuring, suck up the solder of TP.
*:
How to install Batch file into P.C.
(P.66) is required beforehand.
The connections of simulator equipments are as shown in
Adjustment Standard (Base Unit)
(P.67).
Items
Check
Point
Procedure
Check or
Replace Parts
(
A
) 3.5 V Supply Confirma-
tion
VDD3
1. Confirm that the voltage between test point VDD3 and GND is 3.5 V ± 0.2 V.
IC301,R311,
R312,C311,
D301,F301
(
B
) 3.75 V Supply Confirma-
tion
VDD5
1. Confirm that the voltage between test point VDD5 and GND is 3.75 V ± 0.2 V.
IC304,R384,
R385,C385,
D301,F301
(
C
) 2.5 V Supply Confirma-
tion
VDD2
1. Confirm that the voltage between test point VDD2 and GND is 2.5 V ± 0.2 V.
D311,IC303
(
D
) 3.0 V Supply Confirma-
tion
VDD4
1. Confirm that the voltage between test point VDD4 and GND is 3 V ± 0.2 V.
C504,R387,
IC501
(
E
) 1.8 V Supply Confirma-
tion
VDD1
1. Confirm that the voltage between test point VDD1 and GND is 1.8 V ± 0.1 V.
Q351,IC501
(
F
)*
BBIC Confirmation
-
1. BBIC Confirmation (Execute the command “getchk”).
2. Confirm the returned checksum value.
Connection of checksum value and program number is shown below.
IC501
(
G
)* EEPROM Confirmation
-
1. EEPROM Confirmation (Execute the command “sendchar EPV”).
2. Confirm the returned value.
(Value for reference is written at”EEPROM C/SUM” in
Software_Version_Table.xls)
Note:
“checksum” vary depending on the country version. You can find them in the
batch file, PNZZ- mentioned in
The Setting Method of JIG (Base Unit)
(P.65).
IC561
(
H
)* BBIC Clock Adjustment
CLK
GND_C
1. Check X’tal Frequency. (10.368 MHz ± 100 Hz).
Input Command “sendchar sfr”, then you can confirm the current value.
2. If the frequency is not 10.368 MHz ± 100 Hz, Adjust the frequency of CLK exe-
cuting the command “sendchar sfr XX YY (where XX YY is the value)” so that
the reading of the frequency counter is 10.368000 MHz ± 20 Hz.
IC501,X511
Summary of Contents for KX-TG1061M - Cordless Phone Base Station
Page 2: ...2 KX TG1061M KX TG1062M KX TGA106M ...
Page 16: ...16 KX TG1061M KX TG1062M KX TGA106M 4 7 Signal Route ...
Page 17: ...17 KX TG1061M KX TG1062M KX TGA106M ...
Page 18: ...18 KX TG1061M KX TG1062M KX TGA106M ...
Page 23: ...23 KX TG1061M KX TG1062M KX TGA106M ...
Page 24: ...24 KX TG1061M KX TG1062M KX TGA106M 7 1 2 Programming using the Direct Commands ...
Page 25: ...25 KX TG1061M KX TG1062M KX TGA106M ...
Page 26: ...26 KX TG1061M KX TG1062M KX TGA106M 7 1 3 Answering System Settings ...
Page 28: ...28 KX TG1061M KX TG1062M KX TGA106M 7 4 Dialing Mode 7 5 Error Messages ...
Page 30: ...30 KX TG1061M KX TG1062M KX TGA106M ...
Page 31: ...31 KX TG1061M KX TG1062M KX TGA106M ...
Page 32: ...32 KX TG1061M KX TG1062M KX TGA106M 8 Service Mode 8 1 Engineering Mode 8 1 1 Base Unit ...
Page 34: ...34 KX TG1061M KX TG1062M KX TGA106M 8 1 2 Cordless Handset ...
Page 43: ...43 KX TG1061M KX TG1062M KX TGA106M Cross Reference Check Point Base Unit P 51 ...
Page 45: ...45 KX TG1061M KX TG1062M KX TGA106M Cross Reference Check Point Cordless Handset P 55 ...
Page 60: ...60 KX TG1061M KX TG1062M KX TGA106M ...
Page 61: ...61 KX TG1061M KX TG1062M KX TGA106M 10 1 2 Cordless Handset ...
Page 62: ...62 KX TG1061M KX TG1062M KX TGA106M 10 1 3 Charger Unit ...
Page 64: ...64 KX TG1061M KX TG1062M KX TGA106M 10 2 2 How to Replace the Cordless Handset LCD ...
Page 104: ...104 KX TG1061M KX TG1062M KX TGA106M 15 3 Cabinet and Electrical Parts Charger Unit ...
Page 105: ...105 KX TG1061M KX TG1062M KX TGA106M 15 4 Accessories and Packing Materials 15 4 1 KX TG1061M ...
Page 106: ...106 KX TG1061M KX TG1062M KX TGA106M 15 4 2 KX TG1062M ...
Page 107: ...107 KX TG1061M KX TG1062M KX TGA106M 15 4 3 KX TGA106M ...
Page 114: ...114 KX TG1061M KX TG1062M KX TGA106M Y S N KXTG1061M KXTG1062M KXTGA106M ...