1. Solder a pin or lead wire to GND, SDA, and SCLK on base PCB.
2. Plug in AC adaptor to the base.
3. Turn on the power to the JIG (9V).
4. Then connect the cable to each pins using clip.
As for the connection between JIG and PCB, see below photos.
<PC setting and how to reset base PIN to default (0000)>
1. Refer to
PC Setting
().
2. Next, execute <initbspin.bat> by typing "initbspin". The PC
display will be shown as below.
3. After that, turn off DC power supply (9V) to the jig, unplug AC
adaptor, and remove pins on PCB.
Then close the cabinet. The base pin returns to the default (0000)
and you can register a handset to the base using the base PIN
(0000).
6.4. Reset
6.4.1. Base Unit
If the base unit is reset, the Caller ID list will clear.
- To exit the operation, press
any time.
- *1: The factory preset is 0000.
Base Unit Initial Settings