9
KX-TCA256X
4.4.
Circuit Operation (RF Unit)
To measure the charge-current, R616-619 transfer the current to a voltage.
When the charge-current is 200mA, the voltage is 0.05V.
IC602 amplifies the voltage to 24.5time, then the output voltage is 24.5X0.05=1.225V.
IC601 is DC/DC convertor. This IC adjusts CII to 1.25V.
Then the charge current is adjusted to 204mA.
When charging is completed, the BBIC (IC201) of the portable station set the Q103-Base to "High", then Q102 is turned off. As
a result, the charging current is stopped.
4.5.
Signal Route
To measure the charge-current,R616-619 transfer the current to a voltage.
When the charge-current is 200mA,the voltage is 0.05V.
IC602 amplifies the voltage to 24.5time,then the output voltage is 24.5X0.05=1.225V.
IC601 is DC/DC convertor.This IC adjusts CII to 1.25V.
Then the charge current is adjusted to 204mA.
When charging is completed, the BBIC (IC201) of the portable station set the Q103-Base to "High", then Q102 is turned off. As
a result, the charging current is stopped.
Summary of Contents for KX-TCA256X
Page 10: ...10 KX TCA256X 5 Location of Controls and Components 5 1 Location of Controls Handset ...
Page 14: ...14 KX TCA256X 7 2 Settings Menu Chart Handset ...
Page 17: ...17 KX TCA256X 7 5 5 Troubleshooting 7 5 6 Power ON OFF 7 5 7 Using the Handset Phone book ...
Page 24: ...24 KX TCA256X 8 3 Check Battery Charge Handset Note BBIC is IC201 ...
Page 25: ...25 KX TCA256X 8 3 1 Charge OFF Note BBIC is IC201 ...
Page 26: ...26 KX TCA256X 8 4 Check Link Handset Cross Reference Adjustment Handset P 36 ...
Page 28: ...28 KX TCA256X 9 Service Fixture Tools ...
Page 56: ...56 KX TCA256X 15 1 2 Charger Unit ...
Page 57: ...57 KX TCA256X 15 2 Accessories and Packing Materials ...