38
KX-TCA256X
(
N
) Timing Confirmation
-
Follow steps 1 to 3 of
(I)
above.
4.Confirm that the Timing accuracy is < ± 0.5ppm.
IC601,
R631,C649,
IC201
(
O
)* RSSI Level Confirmation
-
Follow steps 1 to 3 of
(I)
above.
4.Set DECT tester power to -81dBm.
5.Execute the command "readrssi".
6.Confirm that the returned value is 0x11±8 (hex).
7.Set DECT tester power to -63dBm.
8.Execute the command "readrssi".
9.Confirm that the returned value is 0x1E±8 (hex).
IC601,
R610,C624,
R614
(
P
) Power RAMP Confirma-
tion
-
Follow steps 1 to 3 of
(I)
above.
4.Confirm that Power RAMP is matching.
IC602,
C651
(
Q
) Audio Check and confir-
mation
-
1. Link to standard BASE which is connected to Line Simulator.
2. Set line voltage to 48V and line current to 40mA.
3. Input -45dBm/1KHz to MIC and measure Line output level.
4. Confirm that the level is reference sample? 1.5dBm and confirm that the dis-
tortion level is < 5%.
5. Input -20dBm/1KHz to Line I/F and measure Receiving level at CN402-1 and
CN402-2.
6. Confirm that the level is reference sample±1.5dBm and confirm that the dis-
tortion level is < 5%.
IC201,
R407,C413,
C415,
CN404,
R418,C425,
CN404
(
R
) SP phone Audio check
and confirmation
-
1. Link to standard Base which is connected to Line Simulator.
2. Set line voltage to 48V and line current to 40mA.
3. Set the handset off-hook using SP-Phone key.
4. Input -45dBm/1KHz to MIC and measure Line output level.
5. Confirm that the level is reference sample±1.5dBm and confirm that the dis-
tortion level is < 5%.
6. Input -20dBm/1KHz to Line I/F and measure Receiving level at CN401-1 and
CN401-2.
7. Confirm that the level is reference sample±1.5dBm and confirm that the dis-
tortion level is < 5%.
IC201,
R408,C410,
IC401,
R405,C430,
C405,C409,
C408,R406,
C407,C432,
IC301,
IC201,
R404,C404,
R403,C403
(
S
) Headset Audio check
and confirmation
-
1. Link to standard BASE which is connected to Line Simulator.
2. Set line voltage to 48V and line current to 40mA.
3. Input -45dBm/1kHz across Mic terminals on headset cable.
4. Confirm that the level is reference sample±1.5dBm and confirm that the dis-
tortion level is < 5%.
5. Input -20dBm/1kHz to Line I/F.
6. Confirm that the level is reference sample±1.5dBm and confirm that the dis-
tortion level is < 5%.
(SP terminals on headset cable is load of 150 ohm)
IC201,
R424,R423,
Q401,
CN404
(
T
)* EEP-ROM confirmation
-
1. EEP-ROM Confirmation (Execute the command "chk255Xv0.1.bat")
2. confirm the returned check sum Value (check sum is 7F1C)
IC201,
CN202,
R206,R207,
R202,R203,
R204
(
U
) RSSI Calibration Confir-
mation
-
1. Set DECT Tester Power to -81dbm.
2. Run "ReadRSSI" and record the returned value.
3. Run "eeprom write" and write the returned value.
WrEeprom 00 50 1 XX
RdEeprom 00 50 1
4. Set DECT Tester Power to -63dbm.
5. Run "ReadRSSI" and record the returned value.
6. Run "eeprom write" and write the returned value.
WrEeprom 00 51 1 XX
RdEeprom 00 51 1
IC201,
CN202,
R206,R207,
R202,R203,
R204
Items
Adjustment
Point
Procedure*
Check or
Replace Parts
Summary of Contents for KX-TCA256X
Page 10: ...10 KX TCA256X 5 Location of Controls and Components 5 1 Location of Controls Handset ...
Page 14: ...14 KX TCA256X 7 2 Settings Menu Chart Handset ...
Page 17: ...17 KX TCA256X 7 5 5 Troubleshooting 7 5 6 Power ON OFF 7 5 7 Using the Handset Phone book ...
Page 24: ...24 KX TCA256X 8 3 Check Battery Charge Handset Note BBIC is IC201 ...
Page 25: ...25 KX TCA256X 8 3 1 Charge OFF Note BBIC is IC201 ...
Page 26: ...26 KX TCA256X 8 4 Check Link Handset Cross Reference Adjustment Handset P 36 ...
Page 28: ...28 KX TCA256X 9 Service Fixture Tools ...
Page 56: ...56 KX TCA256X 15 1 2 Charger Unit ...
Page 57: ...57 KX TCA256X 15 2 Accessories and Packing Materials ...