Items
Adjustment
Point
Procedure
Check
(A
)
Charging
Check
-
1. Connect Charge Contact 12 /2W register between and charge-.
2. Measure and confirm voltage across the regigster is 2.7V ± 0.2V.
D1,R1,R2
Note:
After the measuring, sock up the solder of TP.
The connection of adjustment equipment are as shown in
Adjustment Standard (Charger Unit)
().
14.4. Adjustment Standard (Charger Unit)
When connecting the Simulator Equipments for checking, please refer to below.
14.4.1. Flow Solder Side View
Note:
(A) is refered to
ADJUSTMENTS (BASE UNIT AND CHARGER UNIT)
()
15. ADJUSTMENTS (HANDSET)
If your unit have below symptoms, adjust or confirm each item using remedy column from the
table.
Symptom
Remedy*
The movement of Battery Low indicator is wrong.
Make adjustments in item (A)~(
).
The handset does not respond to a call from base unit.
Make adjustments in item (A)~(
The handset does not transmit or the transmit frequency is off.
Make adjustments in item (A)~(
(M), (O).
The transmit frequency is off.
Make adjustments in item (A)~(
(M), (O).
The transmit power output is low, and the operating distance
between base unit and handset is less than normal.
Make confirmation in item (J),
The reception sensitivity of base unit is low with noise.
Make confirmation in item (N).
Does not link between base unit and handset.
Make adjustments in item (A)~(
The Audio level is high or low.
Make confirmation in item (R).
The SP-Phone level is high or low.
Make confirmation in item (S).
The Headset level is high or low.
Make confirmation in item (T).
* : Refer to
Adjustment (Handset)
()
15.1. Adjustment (Handset)
58
Summary of Contents for KX-TCA151AZV
Page 9: ...9 ...
Page 13: ...6 3 Setting the Ringer Volume 6 3 1 Base Unit 13 ...
Page 14: ...6 3 2 Handset 6 4 Settings Menu Chart 6 4 1 Base Unit 14 ...
Page 15: ...6 4 2 Handset 6 5 PIN Code 6 5 1 Base Unit 15 ...
Page 25: ...Answering System 25 ...
Page 29: ...29 ...
Page 30: ...8 4 2 Entering Names Characters 30 ...
Page 31: ...Cross Reference Phonebook Character Table 8 4 3 Phonebook Character Table 31 ...
Page 32: ...8 4 4 Storing the Number in the Handset Phonebook 32 ...
Page 33: ...8 4 5 Hot Keys Speed Dial 33 ...
Page 35: ...8 5 Handset Registration to a Base Unit 35 ...
Page 36: ...Note for Service At step 7 enter Finally Handset will be linked to Base Unit 36 ...
Page 37: ...8 6 Base Unit Selection 37 ...
Page 44: ...44 ...
Page 45: ...Cross Reference 11 3 2 Handset 45 ...
Page 67: ...2 Put the probes at the receiver terminals as shown below 67 ...
Page 74: ...26 CPU DATA BASE UNIT 26 1 IC2 BBIC 74 ...
Page 95: ...95 ...
Page 97: ...34 ACCESSORIES AND PACKING MATERIALS 97 ...
Page 98: ...34 1 KX TCD510ALV 34 2 KX TCA151AZV 98 ...
Page 99: ...35 TERMINAL GUIDE OF THE ICs TRANSISTORS AND DIODES 35 1 Base Unit 99 ...
Page 115: ...PbF R1 R2 TP4 TP1 TP2 TP3 Digital Volt Meter 12Ω 2W A DC Power Supply 6V ...
Page 130: ...PbF D1 J1 CIRCUIT BOARD CHARGER UNIT Component View ...
Page 131: ...PbF R1 R2 TP4 TP1 TP2 TP3 CIRCUIT BOARD CHARGER UNIT Flow Solder Side View ...
Page 134: ...IC3 IC2 IC1 IC10 PbF Marked ...
Page 136: ...PbF D1 J1 Marked PbF R1 R2 TP4 TP1 TP2 TP3 Marked Component View Flow Solder Side View ...