9.3 CO [3]
184
Programming Manual
Programming Manual References
[400] CO Line Connection
Feature Manual References
1.1.71 Line Access, Outside (CO) Line—SUMMARY
1.1.76 Line Preference—Outgoing
Dial Mode
Selects the type of signal used to dial out using an outside (CO) line.
Default
All outside (CO) lines: DTMF
Value Range
DTMF, Pulse, Call Blocking
Programming Manual References
[401] Dial Mode
Feature Manual References
1.1.39 Dial Type Selection
Pulse Speed
Selects the speed at which pulse signals are sent to the outside (CO) lines for which
Dial Mode
on this
screen is set to
Pulse
or
Call Blocking
.
Default
All outside (CO) lines: 10 pps
Value Range
10 pps, 20 pps
Programming Manual References
[402] Pulse Speed
Feature Manual References
1.1.39 Dial Type Selection
Host PBX Access Codes
Specifies the Host PBX Access code used to access an outside (CO) line from the host PBX.
Default
All outside (CO) lines: — (Not stored)