background image

Electronic Modular Switching System

MODEL 
KX-T206

Please read this manual before connecting the
Electronic Modular Switching System.

ELECTRONIC MODULAR SWITCHING SYSTEM

POWER

Summary of Contents for KX-T206

Page 1: ...Electronic Modular Switching System MODEL KX T206 Please read this manual before connecting the Electronic Modular Switching System ELECTRONIC MODULAR SWITCHING SYSTEM POWER ...

Page 2: ...etary telephone DISA FAX Detect Card Doorphone Model No KX T206 KX T7130 KX T7030 KX T7033 KX T7020 KX T7050 KX T7055 KX T20691 KX T30865 System Component Service Unit Telephone Optional Equipment Notes This Installation Manual does not show complete model numbers that indicate the country where your models should be used The model number of your unit is found on the label affixed to the unit MODE...

Page 3: ...t operate properly chances are that the trouble is in the telephone system and not in the unit Do not use benzine thinner or the like or any abrasive powder to clean the cabinet Wipe it with a soft cloth WARNING WHEN A FAILURE OCCURS WHICH RESULTS IN THE INTERNAL PARTS BECOM ING ACCESSIBLE DISCONNECT THE POWER SUPPLY CORD IMMEDIATELY AND RETURN THIS UNIT TO YOUR DEALER DISCONNECT THE TELECOM CONNE...

Page 4: ...stem Speed Dialing Number Set 19 Dial Type Selection 19 Outgoing Permitted CO1 Assignment Day Night 19 Outgoing Permitted CO2 Assignment Day Night 20 CO1 Ringing Assignment Day Night 20 CO2 Ringing Assignment Day Night 20 Doorphone Assignment Day Night 21 Toll Restriction TRS Class Assignment Day Night 21 TRS Denied Code CLASS 2 3 22 TRS Denied Code CLASS 3 22 OGM Recording 22 OGM Play 23 Fax Conn...

Page 5: ...4 pin connector Doorphone 4 pin connector 7 EXT Connection Cable 1 pair wire single line telephone 2 pair wire proprietary telephone 8 Intercom paths 2 including the doorphone path Characteristics 1 Station Loop Limit Proprietary telephone 40 ohms Single line telephone 600 ohms including set Doorphone 20 ohms 2 Minimum Leak Resistance 15000 ohms 3 Maximum Number of Station Instruments per line 1 p...

Page 6: ...telephone 8 Do not obstruct area around the main unit for reasons of maintenance and inspection be especially careful to allow space for cooling above and at the sides of the main unit Wiring Precautions Make sure to keep the following instructions when wiring 1 Do not wire the telephone cable in parallel with an AC power source computer telex etc If the cables are run near those wires shield the ...

Page 7: ...ight POWER ELECTRONIC MODULAR SWITCHING SYSTEM AC Inlet Power Indicator Inside View of the Main Unit Extension 4 pin Jacks Ground Terminal GROUND SYSTEM EXTN 5 EXTN 3 EXTN 1 CO 2 CO 1 EXTN 6 EXTN 4 EXTN 2 DPH Doorphone Jack CO 4 pin Jack Overview of the Main Unit Name and Location Cable Holders ...

Page 8: ...ground ELECTRONIC MODULAR SWITCHING SYSTEM POWER IMPORTANT Connect the frame of the main unit to ground Templet Wall Mounting 1 Place the templet on page 33 on the wall to mark the three screw positions 2 Install the three screws and washers included into the wall 3 Hook the main unit on the screw heads screw POWER ELECTRONIC MODULAR SWITCHING SYSTEM ...

Page 9: ...ons one pair two pair two pair two pair two pair two pair two pair one pair one pair KX T7030 KX T7130 KX T7050 Single Line Telephone Cordless Phone Telephone Answering Machine with Facsimile KX T7055 KX T7033 KX T7020 to CO1 and CO2 System Connection Diagram One hybrid port and five single line telephone ports A hybrid port accepts either a PT or SLT ...

Page 10: ... A single plug is able to connect two CO lines Use twisted pair cable 1 Lift the transparent part 2 Insert the required telephone wires into the holes of the plug Then press the transparent part back into the black part GROUND SYSTEM EXTN 5 EXTN 3 EXTN 1 CO 2 CO 1 EXTN 6 EXTN 4 EXTN 2 DPH T T R R CO 2 CO 1 CO 2 CO 1 To Modular Jacks from the Central Office Note You can use cable holders to fix the...

Page 11: ...he way into the plug H T R L T R For a proprietary telephone For single line telephones GROUND SYSTEM EXTN 5 EXTN 3 EXTN 1 CO 2 CO 1 EXTN 6 EXTN 4 EXTN 2 DPH H R T L EXTN 1 Notes A proprietary telephone can only be connected to EXTN 1 jack A facsimile must be connected to EXTN 6 jack if an optional DISA FAX Detect card KX T20691 is installed See page 13 to install the card System programming is al...

Page 12: ...r Panasonic KX J66 or USOC RJA2X 4 conductor wiring cord Connect pins H T R and L Paralleled Telephone Connection Notes The paralleled telephone connection is only available for EXTN 1 jack System programming is required See 31 Paralleled Telephone Connection on page 26 The following features are not available for SLT connected in parallel Call Splitting External Feature Access Conference ...

Page 13: ... EXTN 5 EXTN 3 EXTN 1 EXTN 6 EXTN 4 EXTN 2 DPH POWER ELECTRONIC MODULAR SWITCHING SYSTEM The DISA feature allows an outside caller to have direct access to intercom calls System pro gramming is required See 10 OGM Recording on page 22 and 24 Call Incoming Mode Selection on page 26 Keep the following conditions in mind When a caller enters the second digit of an extension number 1 through 6 during ...

Page 14: ... the development of electronic equipment In many countries there are regulations requiring the installation of a lightning protector A lightning strike to a telephone cable which is 10 m 33 feet above ground can be as high as 200 000 volts This system should be installed with lightning protectors In addition grounding connection to earth ground is very important for the protection of the system Re...

Page 15: ...eck obstructions None 3 Composition of the earth rod Metal 4 Depth of the earth rod More than 50 cm 20 inches 5 Size of the grounding wire Thickness is greater than 16 AWG Notes The above figures are recommendations only The length of earth rod and the required depth depend on the composition of the soil CO Lightning Protector Grounding Wire Main Unit Underground Earth Rod Installation of Lightnin...

Page 16: ...nsulation from the ends of the external and internal cables then pass the cables through the rubber packing 2 Remove about 1 cm 13 32 inch of insulation from the end of the earth wire Insert the earth wire through the bottom of the protector base and secure it to the earth terminal 4 Fold the external and internal cables and connect them to the terminal screws using washers 1 Secure the protector ...

Page 17: ...g the AC power cord into the system and an AC outlet The power indicator of the system will light Note The plug adaptor is to be used if the power plug will not fit your socket Assemble as shown in the illustration using the plug which fits your socket In this case be sure to connect the frame of the unit to ground because the ground line in the power cable cannot be used plug adaptor power plug t...

Page 18: ...se KX T7130 KX T7030 or KX T7033 to check the programming Extensions Used for System programming can only be performed from extension 21 Programming To Check the Use KX T7130 KX T7030 or KX T7033 When you check the Programmed Data assignment set the MEMORY switch on the PT to PROGRAM Enter and the program address You cannot check programs 60 62 to 66 and 68 as they are not displayed on the display...

Page 19: ...lanation AA Speed dial number 00 through 79 Phone number 32 digits max Default Not stored 0 0 AA Phone No 0 1 A B Dial Type Selection Description Assigns the Dial Type tone or pulse to CO line Input Format Explanation A 1 CO1 2 CO2 B 0 PULSE 1 TONE Default Both COs 0 PULSE Outgoing Permitted CO1 Assignment Day Night Description Determines the extensions which can have access to CO line 1 in both d...

Page 20: ...n Assigns the extensions which will ring when a call from CO line 2 is received in both day and night modes Input Format Explanation A 1 through 6 corresponding to extension no 21 through 26 B 0 DISABLE not ring 1 ENABLE ring Default extension 21 1 ENABLE other extensions 0 DISABLE CO1 Ringing Assignment Day Night Description Assigns the extensions which will ring when a call from CO line 1 is rec...

Reviews: