Category
Setting Item
Value Range
Default Value
Incoming Call Inter-digit
Timer - DDI/DID
0–30 s
5 s
Incoming Call Inter-digit
Timer - TIE
3–30 s
5 s
PRI23/PRI30 Port
Property—Main
Port
1
–
Port Type
CO (fixed when
Network Type
is set to
Public
)
CO
QSIG-Slave,
QSIG-Master (when
Network Type
is set to
Private
)
Set during "4.4.1 Easy
Setup Wizard"
Connection
INS, OUS, Fault
–
Status Message
No Transmission, When
error detection
(Mandatory), When
error detection (Option /
Mandatory)
No Transmission
Status Receive
Ignore, Disconnect
Ignore
CRC4 Mode
Disable, Enable
Enable
Line Coding
B8ZS, AMI
B8ZS
Frame Sequence
Extend Multi frame
(ESF), 4-Frame Multi
frame (F4), 12-Frame
Multi frame (F12)
Extend Multi frame
(ESF)
PRI23/PRI30 Port
Property—CO Setting
Port
1
–
Port Type
CO (fixed when
Network Type
is set to
Public
)
CO
QSIG-Slave,
QSIG-Master (when
Network Type
is set to
Private
)
Set during "4.4.1 Easy
Setup Wizard"
Connection
INS, OUS, Fault
–
Ringback Tone to
Outside Caller
Disable, Enable
Disable
ISDN Outgoing Call
Type
En-bloc, Overlap
Overlap
Networking Data
Transfer
Off, On
On
Installation Manual
41