5.2 Software Upgrading
Obtaining software updates (downloading the update to the PBX) can be done manually via Web
Maintenance Console. In this case, software updates can be obtained from a USB memory device
connected to the PBX, or a PC that can access Web Maintenance Console.
The software of the following types of devices and components can be updated:
Data Type
Description
Main unit software
Main unit software on the PBX’s motherboard.
Terminal software
Firmware of supported SIP extensions.
*1
Only Panasonic telephones are supported. For details about a specific telephone, refer to the telephone's documentation.
Note
•
To transfer files from USB memory to HTS, store them in the directory below.
/private/meigroup/psn/hts/update/
•
The version of main unit and terminal software can be confirmed through Web-MC.
•
To transfer files from Web-MC to HTS, refer to "4.3.1 Maintenance—[2-1] System Control—Firmware
Transfer to PBX" in the Programming Item List.
•
To update main unit software, refer to "4.3.2 Maintenance—[2-2] System Control—Firmware Update"
in the Programming Item List.
•
Either one Main Unit Software or one Terminal Software is stored in the HTS. If a new Software is
stored when there is already stored Software, the latter will be overwritten.
•
Upon a version up failure, the system automatically reverts back to the former main unit software.
•
Version up failures and automatic reversions to the former main unit software are recorded in the
error log.
•
The version up log containing the error log can be accessed/retrieved from the Web-MC. For more
information, refer to 4.4.2 Maintenance—[3-2] Utility—System Log in Programming Item List.
•
For information on updating terminal software, refer to the corresponding manuals.
5.2 Software Upgrading
Getting Started
103