15.4. Cleaning
15.4.1. Document Feeder/Scanner Glass
Cleaning
Clean the document feeder when:
- Documents frequently misfeed.
- Smudges or black/white lines appear on the original docu-
ment when sending or copying.
1. Disconnect the power cord and the telephone line cord.
2. Open the top cover by pressing the top cover release but-
ton (
).
3. Clean the document feeder rollers (
) and rubber flap
(
) with a cloth moistened with isopropyl rubbing alco-
hol, and let all parts dry thoroughly. Clean the white plate
(
) and scanner glass (
) with a soft and dry cloth.
Caution:
•
Do not use paper products, such as paper towels or
tissues.
4. Connect the power cord and the telephone line cord.
5. Close the top cover securely by pushing down on both
sides.
15.4.2. Thermal Head Cleaning
If smudges or black/white lines appear on a copied/received
document, check whether there is dust on the thermal head.
Clean it to remove the dust.
1. Disconnect the power cord and the telephone line cord.
2. Open the top cover by pressing the top cover release but-
ton (
) and remove the recording paper.
3. Clean the thermal head (
) with a cloth moistened with
isopropyl rubbing alcohol, and let all parts dry thoroughly.
Caution:
•
To prevent a malfunction due to static electricity, do
not use a dry cloth and do not touch the thermal
head directly.
4. Connect the power cord and the telephone line cord.
5. Install the recording paper and close the top cover
securely by pushing down on both sides.
Summary of Contents for KX-FT937LA-B
Page 11: ...11 KX FT937LA B 6 Technical Descriptions 6 1 Connection Diagram ...
Page 21: ...21 KX FT937LA B 6 4 2 Block Diagram ...
Page 23: ...23 KX FT937LA B ...
Page 68: ...68 KX FT937LA B ...
Page 69: ...69 KX FT937LA B CROSS REFERENCE Test Mode P 54 ...
Page 70: ...70 KX FT937LA B CROSS REFERENCE Test Mode P 54 ...
Page 71: ...71 KX FT937LA B CROSS REFERENCE Test Mode P 54 ...
Page 72: ...72 KX FT937LA B CROSS REFERENCE Test Mode P 54 ...
Page 73: ...73 KX FT937LA B ...
Page 74: ...74 KX FT937LA B ...
Page 75: ...75 KX FT937LA B CROSS REFERENCE Test Mode P 54 ...
Page 102: ...102 KX FT937LA B NG Wave pattern Note Refer to NG Example P 107 ...
Page 104: ...104 KX FT937LA B I O and Pin No Diagram ...
Page 106: ...106 KX FT937LA B ...
Page 107: ...107 KX FT937LA B 12 5 5 3 NG Example ...
Page 111: ...111 KX FT937LA B 12 5 7 2 Troubleshooting Flow Chart ...
Page 116: ...116 KX FT937LA B 12 5 11 Thermal Head Section Refer to Thermal Head P 22 ...
Page 117: ...117 KX FT937LA B 13 Service Fixture Tools ...
Page 120: ...120 KX FT937LA B 14 2 Disassembly Procedure 14 2 1 How to Remove the Paper Stacker ...
Page 121: ...121 KX FT937LA B 14 2 2 How to Remove the Operation Panel Block ...
Page 122: ...122 KX FT937LA B 14 2 3 How to Remove the Operation Board LCD and Platen Roller ...
Page 123: ...123 KX FT937LA B 14 2 4 How to Remove the Separation Holder and Document Feed Support ...
Page 124: ...124 KX FT937LA B 14 2 5 How to Remove the Image Sensor CIS and Feed Roller ...
Page 125: ...125 KX FT937LA B 14 2 6 How to Remove the Cutter Unit ...
Page 126: ...126 KX FT937LA B 14 2 7 How to Remove the Lock Lever and Thermal Head ...
Page 127: ...127 KX FT937LA B 14 2 8 How to Remove the Bottom Frame ...
Page 130: ...130 KX FT937LA B 14 2 12 Installation Position of the Lead Wires ...
Page 138: ...138 KX FT937LA B 15 2 3 4 Copying CROSS REFERENCE Sensor Section P 114 ...
Page 142: ...142 KX FT937LA B 16 1 4 Power Supply Board ...
Page 146: ...146 KX FT937LA B Refer to Analog Board Section P 108 ...
Page 147: ...147 KX FT937LA B 16 3 Test Chart 16 3 1 ITU T No 1 Test Chart ...
Page 148: ...148 KX FT937LA B 16 3 2 ITU T No 2 Test Chart ...
Page 155: ...155 KX FT937LA B MEMO ...
Page 165: ...165 KX FT937LA B 20 1 2 Upper Cabinet Section ...
Page 166: ...166 KX FT937LA B 20 1 3 Lower Cabinet Section ...
Page 167: ...167 KX FT937LA B 20 1 4 Gear Block Section ...
Page 168: ...168 KX FT937LA B 20 1 5 Screws ...
Page 169: ...169 KX FT937LA B 20 1 6 Accessories and Packing Materials ...