3. Facsimile Call Time Series
Facsimile Call Time Series
As shown in the following diagram, the facsimile call time series is divided into five phases.
Phase A : Call setting
Call setting can be manual/automatic.
Phase B : Pre-message procedure
Phase B is a pre-processing procedure and sequence for confirming the status of the terminal, transmission route, etc., and for
terminal control. It implements terminal preparation status, determines and displays terminal constants, confirms
synchronization status, etc. and prepares for transmission of facsimile messages.
Phase C : Message transmission
Phase C is the procedure for the transmitting facsimile messages.
Phase D : Post message procedure
Phase D is the procedure for confirming that the message is completed and received. For continuous transmission, phase B
or phase C is repeated for transmission.
Phase E : Call retrieval
Phase E is the procedure for call retrieval, that is for circuit disconnection.
4. Concerning Transmission Time
Transmission Time
= Control Time
+ Image Transmission Time
+ Hold Time
Transmission time consists of the following.
Control time:
This is time at the start of transmission when the functions at the sending and receiving sides are confirmed, the
transmission mode is established, and transmission and reception are synchronized.
Image transmission time:
This is the time required for the transmission of document contents (image data). In general, this time is recorded in the
catalog, etc.
Hold time:
This is the time required after the document contents have been sent to confirm that the document was actually sent, and
to check for telephone reservations and/or the existence of continuous transmission.
5. Facsimile Standards
Item
Telephone Network Facsimile
G3 Machine
Connection Control Mode
Telephone Network Signal Mode
Terminal Control Mode
T. 30 Binary
Facsimile Signal Format
Digital
Modulation Mode
PSK (V. 27 ter) or QAM (V. 29)
Transmission Speed
300 bps (Control Signal)
2400, 4800, 7200, 9600 12000, 14400 bps (FAX Signal)
Redundancy Compression
Process
(Coding Mode)
1 dimension : MH Mode
2 dimension : MR Mode (K=2.4)
Resolution
Main Scan : 8 pel/mm
Sub Scan : 3.85, 7.7l/mm
Line Synchronization Signal
EOL Signal
1 Line Transmission Time
[ms/line]
Depends on the degree of data reduction.
Minimum Value : 10, 20
Can be recognized in 40ms.
141
KX-FP362BX
Summary of Contents for KX-FP362BX
Page 21: ...4 1 2 COMPONENT LOCATIONS 21 KX FP362BX ...
Page 33: ...5 2 2 HOW TO REMOVE THE OPERATION PANEL BLOCK 33 KX FP362BX ...
Page 34: ...5 2 3 HOW TO REMOVE THE OPERATION BOARD AND LCD 34 KX FP362BX ...
Page 35: ...5 2 4 HOW TO REMOVE THE IMAGE SENSOR CIS 35 KX FP362BX ...
Page 36: ...5 2 5 HOW TO REMOVE THE THERMAL HEAD 36 KX FP362BX ...
Page 37: ...5 2 6 HOW TO REMOVE THE PLATEN ROLLER AND BACK COVER 37 KX FP362BX ...
Page 38: ...5 2 7 HOW TO REMOVE THE PICKUP ROLLER 38 KX FP362BX ...
Page 39: ...5 2 8 HOW TO REMOVE THE CASSETTE LEVER 39 KX FP362BX ...
Page 40: ...5 2 9 HOW TO REMOVE THE BOTTOM FRAME 40 KX FP362BX ...
Page 41: ...5 2 10 HOW TO REMOVE THE DIGITAL ANALOG POWER SUPPLY SENSOR BOARDS AND AC INLET 41 KX FP362BX ...
Page 42: ...5 2 11 HOW TO REMOVE THE MOTOR BLOCK AND SEPARATION ROLLER 42 KX FP362BX ...
Page 43: ...5 2 12 HOW TO REMOVE THE GEARS OF MOTOR BLOCK 43 KX FP362BX ...
Page 44: ...5 3 INSTALLATION POSITION OF THE LEAD WIRES 44 KX FP362BX ...
Page 57: ...6 5 2 SREVICE MODE SETTINGS Note The above values are the default values 57 KX FP362BX ...
Page 71: ...71 KX FP362BX ...
Page 85: ...85 KX FP362BX ...
Page 86: ...CROSS REFERENCE TEST FUNCTIONS P 50 86 KX FP362BX ...
Page 87: ...CROSS REFERENCE TEST FUNCTIONS P 50 87 KX FP362BX ...
Page 88: ...CROSS REFERENCE TEST FUNCTIONS P 50 88 KX FP362BX ...
Page 89: ...CROSS REFERENCE TEST FUNCTIONS P 50 89 KX FP362BX ...
Page 90: ...90 KX FP362BX ...
Page 91: ...91 KX FP362BX ...
Page 92: ...CROSS REFERENCE TEST FUNCTIONS P 50 92 KX FP362BX ...
Page 96: ...96 KX FP362BX ...
Page 100: ...I O and Pin No Diagram 100 KX FP362BX ...
Page 104: ...6 6 7 3 NG EXAMPLE 104 KX FP362BX ...
Page 108: ...Note Refer to CHECK SHEET P 105 and TEST FUNCTIONS P 50 108 KX FP362BX ...
Page 110: ...6 6 10 2 TROUBLESHOOTING FLOW CHART 110 KX FP362BX ...
Page 116: ...6 6 14 THERMAL HEAD SECTION Refer to THERMAL HEAD P 131 116 KX FP362BX ...
Page 117: ...7 CIRCUIT OPERATIONS 7 1 CONNECTION DIAGRAM 117 KX FP362BX ...
Page 119: ...7 2 1 GENERAL BLOCK DIAGRAM 119 KX FP362BX ...
Page 121: ...7 3 2 MEMORY MAP 121 KX FP362BX ...
Page 130: ...7 4 2 BLOCK DIAGRAM 130 KX FP362BX ...
Page 133: ...TIMING CHART i Print Duty 50 or less ii Print Duty more than 50 133 KX FP362BX ...
Page 152: ...152 KX FP362BX ...
Page 159: ...8 REFERENCE MATERIAL DATA 8 1 TERMINAL GUIDE OF THE ICs TRANSISTORS AND DIODES 159 KX FP362BX ...
Page 162: ...8 3 TEST CHART 8 3 1 ITU T No 1 TEST CHART 162 KX FP362BX ...
Page 163: ...8 3 2 ITU T No 2 TEST CHART 163 KX FP362BX ...
Page 164: ...9 FIXTURES AND TOOLS 164 KX FP362BX ...
Page 165: ...10 CABINET MECHANICAL AND ELECTRICAL PARTS LOCATION 10 1 GENERAL SECTION 165 KX FP362BX ...
Page 166: ...10 2 OPERATION PANEL SECTION 166 KX FP362BX ...
Page 167: ...10 3 BACK COVER SECTION 167 KX FP362BX ...
Page 168: ...168 KX FP362BX ...
Page 169: ...10 4 UPPER CABINET SECTION 169 KX FP362BX ...
Page 170: ...10 5 LOWER CABINET P C BOARD SECTION CROSS REFERENCE MOTOR SECTION P 171 170 KX FP362BX ...
Page 171: ...10 6 MOTOR SECTION 10 7 ACTUAL SIZE OF SCREWS 171 KX FP362BX ...
Page 172: ...11 ACCESSORIES AND PACKING MATERIALS 172 KX FP362BX ...