Access indicator
–
Live indicator
•
On:
All the indicators will light in accordance with the status.
•
On(Access):
Only the live indicator will light when images are viewed.
•
Off:
All the indicators will light off.
•
Default:
On
Note
•
LINK indicator (orange):
This indicator will light when communication with the connected device is
available.
•
ACT Indicator (green):
This indicator will light when accessing a network.
•
STATUS indicator (red/orange/green):
The live indicator will light or blink as follows depending on
the camera status.
Operation status
Indicator status
When the power is turned on
Before the network
connection is established
Lights orange
®
Lights off
®
Blinks
orange
®
Lights orange
When the network
connection is established
Lights orange
®
Lights off
®
Blinks
orange
®
Blinks green
®
Lights
green
During standby or connection (Cable is not connected.)
Lights orange
During standby or connection (Cable is connected.)
Lights green
During the upgrade process
Blinks orange
During the initialization
Lights orange
®
Lights off
®
Blinks
orange
®
Lights orange
Port forwarding error caused by the UPnP function
Blinks orange (in 2 seconds
intervals (on for 1 second / off for 1
second))
Trouble happening on the camera
Blinks red
Trouble with the installation position of the camera
Lights red
[Alarm status update mode]
Select an interval of the camera status notification from the following.
When the status of the camera changes, the alarm occurrence indication button or the [AUX] button will be
displayed to notify of the camera status.
•
Polling(30s):
Updates the status each 30 seconds and provide notification of the camera status.
•
Real time:
Provide notification of the camera status when the status has changed.
•
Default:
Real time
Note
•
Depending on the network environment, notification may not be provided in real time.
•
When multiple cameras are using the same “Alarm status reception port”, even if “Real time” is selected
for “Alarm status update mode”, status notification is not provided in real time. In this case, change the
“Alarm status reception port” settings.
Operating Instructions
41
7 Configure the basic settings of the camera [Basic]