BRI1/BRI2 Card

Accessory (included):

 Extension Bolt 

×

 1, Strap 

×

 1, Optional Card Label 

×

 1 (for BRI1 card)

User-supplied (not included): 

RJ45 connector

Notes

Connect these optional service cards to the trunk through an NT1; do not connect to 
the  U interface of the trunk directly.

These optional service cards have 100

 of terminal resistance. For use in point to 

multi-point connection, the cards must be placed at the end of the bus.

2.5

Installing the Extension Cards (DLC8/SLC8)

Accessory (included):

 Extension Bolt 

×

 1, Strap 

×

 1

User-supplied (not included):

 RJ45 connector

To NT1

RJ45 (LINE 1)
RJ45 (LINE 2)

Example: BRI2 Card

To extension

RJ45

Example: DLC8 Card

Summary of Contents for Hybrid IP-PBX

Page 1: ... this manual carefully before using this product and save this manual for future use KX TDA15 Version 1 1 Hybrid IP PBX Getting Started Table of Contents 2 4 12 15 21 1 Before Installation 2 Installation 3 Starting the Hybrid IP PBX 4 Customising the Hybrid IP PBX 5 Confirming the Connection ...

Page 2: ...X T7600 DPT KX T7600 DPT for Single Line Device for Digital Proprietary Telephone DPT DSS Console and Portable Station PS for Single Line Device DPT Analogue Proprietary Telephone APT DSS Console and PS Private IP Network Station Message Detail Recording SMDR PC Router DLC8 KX TDA3172 SLC8 KX TDA3174 DPH4 KX TDA3161 DPH2 KX TDA3162 ECHO8 KX TDA3166 EXT CID MSG2 KX TDA3191 IP GW4 KX TDA3480 Telepho...

Page 3: ...or PC connection Connector RJ45 for trunk and extension connections Note Use a twisted pair cable for the RJ45 connector AC Cord 1 AC Adaptor 1 Screw 5 Washer 5 Mini Plug for pager and music source 2 SD Memory Card 1 Main Strap 1 Optional Card Label Sheet 1 The type of the AC cord may vary depending on the country area of use Diameter of cable ø 0 4 mm to ø 0 6 mm Maximum length of cable ø 0 5 mm ...

Page 4: ...e Covers 1 Pull the slide button to the right and holding it slide the cable cover upwards Then turn the cable cover slightly to remove it 2 Remove the three screws 3 Holding the protrusions on both sides of the front cover swing the cover open Slide Button Cable Cover Screw ...

Page 5: ...ose the front cover then tighten the three screws 2 Attach the rear hooks on the cable cover to the main unit then swing the cable cover closed so that the front hooks fit in place 3 Slide the cable cover down until it locks Screw Cable Cover ...

Page 6: ...ybrid IP PBX to fail to start when you try to restart the system 2 3 Installing the Optional Service Cards Slot Position 1 Slots 10 and 11 accept only cards which do not have external ports Therefore these slots do not have removable cover plates 2 Slot 08 contains the pre installed EXT CID card 3 Slot 02 contains the pre installed BRI2 card 4 Slot 01 contains the pre installed Super Hybrid Ports ...

Page 7: ...BRI2 BRI2 BRI2 BRI1 BRI2 LCOT2 BRI2 BRI1 LCOT2 CAUTION To protect the main board from static electricity do not touch parts on the main board or on the optional service cards To discharge static electricity touch ground or wear an earthing strap Card Slot Number Type Max 03 04 05 06 09 10 11 LCOT2 1 BRI2 1 BRI1 1 IP GW4 1 DLC8 1 1 1 Only one of either DLC8 or SLC8 card can be installed SLC8 DPH4 1...

Page 8: ...over plates 2 Position the card in the open slot making sure that the tabs on the both sides of the card fit into place Then holding the card firmly in place lower the rear end so that the hole of the card fits over the extension bolt CAUTION When installing the optional service cards do not put pressure on any parts of the main board Doing so may result in damage to the Hybrid IP PBX Dummy Cover ...

Page 9: ...ded with the card into the hole on the card and tighten it to secure the card 2 4 Installing the Trunk Cards LCOT2 Card Accessory included Extension Bolt 1 Strap 1 Optional Card Label 1 User supplied not included RJ45 connector Extension Bolt To trunk RJ45 ...

Page 10: ...T1 do not connect to the U interface of the trunk directly These optional service cards have 100 of terminal resistance For use in point to multi point connection the cards must be placed at the end of the bus 2 5 Installing the Extension Cards DLC8 SLC8 Accessory included Extension Bolt 1 Strap 1 User supplied not included RJ45 connector To NT1 RJ45 LINE 1 RJ45 LINE 2 Example BRI2 Card To extensi...

Page 11: ...ise and lightning strikes but it may not be enough to protect the Hybrid IP PBX A permanent connection between earth and the earth terminal of the Hybrid IP PBX must be made 1 Loosen the screw 2 Insert an earthing wire user supplied 3 Tighten the screw 4 Connect the earthing wire to earth For earthing wire green and yellow insulation is required and the cross sectional area of the conductor must b...

Page 12: ...f you unplug the Hybrid IP PBX do not perform the following procedures to start the Hybrid IP PBX again Otherwise your programmed data will be cleared The Hybrid IP PBX will continue to be powered even if the power switch is turned OFF The power supply cord is used as the main disconnect device ensure that the socket outlet is located installed near the equipment and is easily accessible 1 Set the...

Page 13: ...g the AC cord into the AC adaptor and then plug the other end into an AC outlet 4 Turn on the power switch Notes For safety reasons follow the procedures as indicated when turning on the Hybrid IP PBX AC Adaptor DC Connector DC IN 1 2 1 AC Adaptor AC Cord To AC outlet Power Switch ...

Page 14: ... 10 s return the System Initialise Switch to the NORMAL position Depending on the configuration initialisation takes about 1 min to 3 min If successfully executed the RUN indicator will stop flashing and be kept lit All data will be cleared and the Hybrid IP PBX will be initialised to the default values The DPTs should show the time as 01 00 Note Use the same types of AC adaptor and AC cord that a...

Page 15: ...tup lets you easily configure the Hybrid IP PBX to receive intercom and trunk calls as well as apply basic settings such as time and date Note The contents and design of the software are subject to change without notice 4 1 Connecting the PC To programme the Hybrid IP PBX connect it to the PC with serial interface Serial Interface Connection USB Port RS 232C Port PC PC To USB Port To COM Port RS 2...

Page 16: ...Setup will launch automatically During Quick Setup you will setup the following basic items Date and Time of the Hybrid IP PBX The date and time set on the PC will be used System Password for installer for PC programming Operator extension numbers Operator extensions for all time modes day lunch break night can be assigned Flexible Numbering type to pattern 1 or pattern 2 If pattern 1 with is sele...

Page 17: ...nnection with the Hybrid IP PBX 5 a Type the system password for installer default 1234 b Click OK 6 When country area data do not match a Click OK to replace the country area data of the Hybrid IP PBX Replacement may take several minutes to complete b Follow the procedure described in 3 Starting the Hybrid IP PBX and restart the Hybrid IP PBX c Repeat steps 2 to 5 to restart the KX TDA30 Maintena...

Page 18: ...onfiguration The programme menu appears 1 a Double click Configuration b Double click Slot c Change the status of the BRI card to OUS d Click Cancel 2 Click Tool BRI Automatic Configuration from the menu bar 3 a Click Check to turn on the BRI card b Click OK ...

Page 19: ... Click Close 5 a Double click Slot b Change the status of the BRI card to INS c Click Cancel For analogue trunk user DIL Setting 1 Double click CO Incoming Call 2 Double click DIL Table Port Setting 3 Click the DIL tab 4 For necessary items enter the proper numbers and selections 5 Click OK For ISDN trunk user DDI Setting 1 Double click CO Incoming Call 2 Double click DDI DID Table 3 For necessary...

Page 20: ... the Main tab 8 For necessary items enter the proper numbers and selections 9 Click OK 1 Double click Configuration 2 Double click Extension Port 3 Change the connection of the desired port to OUS 4 For DPT Property set the Type to DSS and assign the Location number 5 Click OK 6 Double click Extension 7 Double click DSS Console 8 Double click Main 9 Type the Pair Extension Number 10 Click OK 11 Do...

Page 21: ...call an outside party 14 Double click Configuration 15 Double click Extension Port 16 Change the connection of the appropriate port to INS 17 Click OK Off hook Talk Dial extension number extension no Off hook Talk Dial outside phone number Enter automatic line access number 9 0 outside phone no ...

Page 22: ... 5 EC If you would like to receive a copy of the original Declaration of Conformity of our products which relates to the R TTE please visit our web address http doc panasonic de Panasonic Communications Co Ltd 1 62 4 chome Minoshima Hakata ku Fukuoka 812 8531 Japan Copyright This manual is copyrighted by Panasonic Communications Co Ltd PCC You may print out this manual solely for internal use with...

Reviews: