Q
The Maintenance Console cannot connect to the PBX via modem.
A
•
Is the dial number of the modem correct? For more details, see
13.1 [11-1] Main
.
•
Has a modem been installed to the PBX?
•
Are the modem settings of the PBX and Maintenance Console correct? For more
details, see
13.1 [11-1] Main
.
•
Is the password correct?
•
Is the Maintenance Console not connected to the PBX by another connection method?
Q
The Maintenance Console cannot connect to the PBX via ISDN Remote.
A
•
Are the ISDN Remote settings of the PC correct? For more details, see
13.1 [11-1]
Main
.
•
Is the ISDN Remote dial number correct?
•
Is the password correct?
•
Is the Maintenance Console not connected to the PBX by another connection method?
Q
Can I perform initial setup of the PBX without being connected to the PBX?
A
•
Yes. This is possible in Batch mode.
Create a new system data file using
2.2.1 Start Menu—New
, edit settings as required,
and then upload this file to the PBX later (see
2.6.2 Utility—File Transfer PC to PBX
(SD Card)
).
Maintenance Console Software
Q
How do I confirm the software version of the PBX or installed cards?
A
•
From
3.1 [1-1] Slot
, click
Summary
. Summary information, including software
versions, is displayed for all cards installed in the PBX.
Q
Not all of the characters of a setting can be displayed because the column is too
narrow.
A
•
Move the mouse to the line between the names of 2 setting items, at the top of the table.
The pointer will change to a double arrow. Click and drag the line to the right until all
characters are displayed.
Card Status
Q
The status of a new card will not change to "INS".
A
•
With the new card installed, does the total number of extensions or trunks exceed the
maximum supported by the PBX?
•
Is the type of card installed in the slot different from the card type set as "Pre-Install" for
that slot? Confirm that the correct card is installed in the slot.
•
Is the card firmly and fully installed in the slot? Confirm that the card is installed correctly
in the slot.
•
Confirm that the card is not damaged.
Q
I want to set the status of only 1 port of the IP-GW4 card to "OUS".
PC Programming Manual
89
2.7.1 Frequently Asked Questions (FAQ)
Summary of Contents for HYBRID IP-PBX KX-TDA100
Page 10: ...10 PC Programming Manual Table of Contents ...
Page 14: ...Table 2 For CE model 14 PC Programming Manual 1 1 2 Entering Characters ...
Page 15: ...Table 3 For RU model PC Programming Manual 15 1 1 2 Entering Characters ...
Page 16: ...Table 4 For GR model 16 PC Programming Manual 1 1 2 Entering Characters ...
Page 98: ...98 PC Programming Manual 2 7 1 Frequently Asked Questions FAQ ...
Page 99: ...Section 3 1 Configuration PC Programming Manual 99 ...
Page 357: ...Section 4 2 System PC Programming Manual 357 ...
Page 486: ...486 PC Programming Manual 4 20 2 11 2 Audio Gain Card ...
Page 487: ...Section 5 3 Group PC Programming Manual 487 ...
Page 562: ...562 PC Programming Manual 5 28 3 10 Broadcasting Group Member List ...
Page 563: ...Section 6 4 Extension PC Programming Manual 563 ...
Page 725: ...Section 7 5 Optional Device PC Programming Manual 725 ...
Page 753: ...Section 8 6 Feature PC Programming Manual 753 ...
Page 774: ...2 2 3 Tenant Service 774 PC Programming Manual 8 6 6 6 Tenant ...
Page 775: ...Section 9 7 TRS PC Programming Manual 775 ...
Page 783: ...Section 10 8 ARS PC Programming Manual 783 ...
Page 795: ...Section 11 9 Private Network PC Programming Manual 795 ...
Page 807: ...Section 12 10 CO Incoming Call PC Programming Manual 807 ...
Page 835: ...Section 13 11 Maintenance PC Programming Manual 835 ...
Page 857: ...Section 14 Appendix PC Programming Manual 857 ...
Page 911: ...PC Programming Manual 911 Notes ...