2-5
Conditions When Output Data Become Unfixed
The operation status will be judged as a data unfixed status (i.e., there is no determined
data) immediately after settings changes are made, the system is reset, or laser stop input
is turned ON. This status is not an alarm status.
The data unfixed status starts at the time of restarting measurement after setting
refreshment or resetting until the number of data measurement times reaches an average.
Under the data unfixed status, a digital output of -999.9999 [mm] and an analog
output of 11.000 [V] or 21.6 [mA]
*1
will be turned ON.
*1 This is the initial value. Under the data unfixed status, the analog output of the
system can be changed to a fixed value. For more information,
refer to
“3
-3-7 Alar
m Settings”
–
“Analog Output at Alarm”
.
*2 Under the data unfixed status, the zero set input will be ignored.
*3 For cancelling the data unfixed status,
refer to
Chapter 5
“Troubleshooting”
.
For example, the graph on the right-hand
side shows the digital display at reset input
for NORMAL measurement.
The table below shows the measurement
value display and output under the data
unfixed status or alarm status.
Data unfixed status
Alarm status
Status
Measurement data is unfixed.
(Average buffer has not reached
the setting number of times.)
Measurement disabled status due to
poor light intensity or when the target
object is off the measurement range.
Measurement
Value Display
「――――――」
The previous value (default) is kept
on hold.
Analog output
The previous value (default) is
kept on hold.
The previous value (default) is kept
on hold.
Digital output
(High
function type
only)
-999.9999 [mm]
The previous value (default) is kept
on hold.
Judgment
Output
LO judgment
Interlocks with digital output
Alarm output
Interlocks with alarm status
ON
Reset input
Data unfixed status
(
Data remeasurement
period
)
Ramco National
800-280-6933 | [email protected]
www.panasonicsensors.com
Summary of Contents for HL-G1*A-RA-C5 Series
Page 18: ...Ramco National 800 280 6933 nsales ramcoi com www panasonicsensors com ...
Page 98: ...Ramco National 800 280 6933 nsales ramcoi com www panasonicsensors com ...
Page 130: ...Ramco National 800 280 6933 nsales ramcoi com www panasonicsensors com ...
Page 157: ...Ramco National 800 280 6933 nsales ramcoi com www panasonicsensors com ...