4.2 Operation Check

4-8

WUME-HGF1UM-2

Ramco Innovations www.ramcoi.com Got Questions?  Phone 800-280-6933  Email [email protected]

Summary of Contents for HG-F Series

Page 1: ... Laser Distance Sensor HG F1 Series User s Manual WUME HGF1UM 2 2023 2 Ramco Innovations www ramcoi com Phone 800 280 6933 Ramco Innovations www ramcoi com Got Questions Phone 800 280 6933 Email nsales ramcoi com ...

Page 2: ... MEMO 2 WUME HGF1UM 2 Ramco Innovations www ramcoi com Got Questions Phone 800 280 6933 Email nsales ramcoi com ...

Page 3: ...er explains the system configuration Chapter 3 Installation and Connection This chapter explains installation connection wiring and other work Chapter 4 Basic Settings This chapter explains how to perform basic operations and check operations before staring detection Chapter 5 Setting Items and Setting Methods This chapter explains details and settings for various functions Chapter 6 Maintenance T...

Page 4: ... MEMO iv WUME HGF1UM 2 Ramco Innovations www ramcoi com Got Questions Phone 800 280 6933 Email nsales ramcoi com ...

Page 5: ... 2 4 1 1 Flow of Operations up to Setup Completion 4 2 4 1 2 Emitted Beam Spot Check Mode 4 4 4 1 3 2 point Teaching Normal Sensing Mode 4 5 4 2 Operation Check 4 7 5 Setting Items and Setting Methods 5 1 5 1 List of Setting Items 5 2 5 2 Threshold Fine Adjustment 5 6 5 3 Threshold Selectable 5 7 5 4 Peak Bottom Hold Function 5 9 5 5 Zero Set Function 5 10 5 5 1 Zero Set Setting 5 10 5 5 2 Zero Se...

Page 6: ...intenance and Inspection 6 2 6 1 1 Maintenance Precautions 6 2 6 1 2 Main Inspection Items 6 2 7 Troubleshooting 7 1 7 1 Solutions to Problems 7 2 7 2 Error Display 7 3 8 Specifications and Dimensions 8 1 8 1 Specifications 8 2 8 2 Shapes and Dimensions 8 5 8 2 1 Products 8 5 8 2 2 Simple Mounting Bracket MS HG 01 Including two M3 screws with washer 8 6 8 2 3 Simple Mounting Bracket Attachment Dia...

Page 7: ...ing Precautions 1 3 1 3 Terminology 1 7 1 4 Regulations and Standards 1 8 1 5 Laser Safety Standards 1 9 1 5 1 IEC JIS GB KS 1 9 1 5 2 FDA 1 10 1 6 Contents of Package 1 12 WUME HGF1UM 2 1 1 Ramco Innovations www ramcoi com Got Questions Phone 800 280 6933 Email nsales ramcoi com ...

Page 8: ...conform to the laws and standards related to personal protection in each country such as OSHA ANSI and IEC This product is intended to be used to detect target objects and is not provided with control functions that prevent accidents to ensure safety Avoid observing beams in a dark surrounding environment Do not stare into laser beam with an optical device such as telephoto optics Never attempt to...

Page 9: ...beam receiving part proper measurement may not be possible When the reflectance of a detection object is high be careful in installation Do not perform wiring or maintenance with wet hands Doing so may cause an electric shock Power supply Verify that the supply voltage fluctuations are within the rating when using the product Note that applying a voltage greater than the rated voltage or directly ...

Page 10: ...n the middle of saving the settings such as teaching or PRO mode settings In the worst case the memory in the sensor may be damaged and restarting may not be possible Depending on the instantaneous power failure time there are cases where the operation is continued or where the operation is reset to the initial state as when the power is turned ON Do not use the product in an environment where ins...

Page 11: ...ronment where dew condensation may occur due to a sudden temperature change Use the product with illuminance of 3 000 lx or less on the light receiving surface of an incandescent lamp Do not use the product in a location where the ambient temperature ambient humidity and illuminance on the light receiving surface exceed the operating environment ranges Avoid using this product in environments wher...

Page 12: ...ar zone shield the laser within 24 m Other matters When this product becomes unusable or unnecessary dispose of the product properly as industrial waste in accordance with the applicable law in the country When exporting the product or when taking it out of Japan the user is required to check applicable standards laws and regulations If the user resells or transfers our company products to a third...

Page 13: ...to be identified more brightly than under the normal measurement conditions Normal sensing mode In this mode control output ON OFF is controlled for a single threshold Window comparator mode In this mode control output ON OFF is controlled by setting two thresholds threshold 1 and threshold 2 Teaching Refers to setting measured values to the threshold values by using an actual object to be detecte...

Page 14: ...pplied Conforming standards USA Canada Standards UL 61010 1 CAN CSA No 61010 1 Other standards IEC 60825 1 JIS C 6802 GB 7247 1 KS C IEC 60825 1 When using this product in a region other than those listed above be sure to check and comply with the regulations and standards applicable in the country or region where the product is used 1 4 Regulations and Standards 1 8 WUME HGF1UM 2 Ramco Innovation...

Page 15: ...duct belongs to Class 1 laser products according to IEC 60825 1 JIS C 6802 GB 7247 1 KS C IEC 60825 1 Safety of Laser Products Explanation of danger level Classificatio n Overview of hazard evaluation Class 1 A laser that is safe when operated under operating conditions that can be reasonably foreseen Note 1 When an unexpected failure occurs dangerous radiation may be generated Therefore pay speci...

Page 16: ...shed as one of the FDA regulations These standards classify laser products into classes according to the hazard level of laser and prescribe safety and preventive measures that should be implemented for each class This product complies with the FDA regulations FDA 21 CFR 1040 10 and 1040 11 in accordance with FDA Laser Notice No 56 except for complying with IEC 60825 1 Ed 3 Class 1 laser product W...

Page 17: ... Certificate identification label 1 5 Laser Safety Standards WUME HGF1UM 2 1 11 Ramco Innovations www ramcoi com Got Questions Phone 800 280 6933 Email nsales ramcoi com ...

Page 18: ...ate identification label 1 pc Installation Instructions Manual English Japanese Chinese Korean 1 volume each General Information for Safety Compliance and Instructions 1 volume Mounting bracket optional MS HG 01 Simple mounting bracket Bracket 1 set M3 screw with washer length 25 mm 2 pcs 1 6 Contents of Package 1 12 WUME HGF1UM 2 Ramco Innovations www ramcoi com Got Questions Phone 800 280 6933 E...

Page 19: ...2 System Configuration 2 1 Principle of Measurement 2 2 2 2 Description of Parts 2 3 WUME HGF1UM 2 2 1 Ramco Innovations www ramcoi com Got Questions Phone 800 280 6933 Email nsales ramcoi com ...

Page 20: ...beam that is emitted from the sensor and reflected on the measurement object to return to the sensor The measured time is converted into a distance TOF system 2 1 Principle of Measurement 2 2 WUME HGF1UM 2 Ramco Innovations www ramcoi com Got Questions Phone 800 280 6933 Email nsales ramcoi com ...

Page 21: ...n is used to check measured values and indicators as well as to specify and change settings for each function Operation display section Name Function 1 Digital display Red Displays measured values and settings 2 PRO indicator Yellow Lights up when PRO mode is set 3 Zero set indicator Yellow Lit while the zero set function is ON 4 Teaching indicator Yellow Lit while teaching is in progress 2 2 Desc...

Page 22: ...iation indicator Green Lit while laser beams are being emitted 7 TEACH key Use to change setting items and settings when configuring settings 8 UP key 9 DOWN key 2 2 Description of Parts 2 4 WUME HGF1UM 2 Ramco Innovations www ramcoi com Got Questions Phone 800 280 6933 Email nsales ramcoi com ...

Page 23: ...and Connection 3 1 Installation Method 3 2 3 2 Wiring Connection Diagram 3 4 3 3 Adjusting the beam axis 3 5 WUME HGF1UM 2 3 1 Ramco Innovations www ramcoi com Got Questions Phone 800 280 6933 Email nsales ramcoi com ...

Page 24: ...th those of other sensors To prevent the product from falling due to loose screws take prevention measures such as using screws with washers depending on the operating environment Do not mount the sensors closely side by side to prevent heat generation Otherwise the product temperature may exceed the specified temperature due to heat generation Use the tightening torque of 0 5 N m or less even whe...

Page 25: ...3 1 Installation Method WUME HGF1UM 2 3 3 Ramco Innovations www ramcoi com Got Questions Phone 800 280 6933 Email nsales ramcoi com ...

Page 26: ... N NPN type HG F13A A P PNP type Note 1 Insulate unused terminals to avoid error input or short circuit 3 2 Wiring Connection Diagram 3 4 WUME HGF1UM 2 Ramco Innovations www ramcoi com Got Questions Phone 800 280 6933 Email nsales ramcoi com ...

Page 27: ...cking the spot beam to adjust the beam axis When adjusting the beam axis set the emitted beam spot check mode in which the spot beam can be more easily observed For the setting procedure of the emitted beam spot check mode refer to 4 1 2 Emitted Beam Spot Check Mode 3 3 Adjusting the beam axis WUME HGF1UM 2 3 5 Ramco Innovations www ramcoi com Got Questions Phone 800 280 6933 Email nsales ramcoi c...

Page 28: ... MEMO 3 6 WUME HGF1UM 2 Ramco Innovations www ramcoi com Got Questions Phone 800 280 6933 Email nsales ramcoi com ...

Page 29: ... of Operations up to Setup Completion 4 2 4 1 2 Emitted Beam Spot Check Mode 4 4 4 1 3 2 point Teaching Normal Sensing Mode 4 5 4 2 Operation Check 4 7 WUME HGF1UM 2 4 1 Ramco Innovations www ramcoi com Got Questions Phone 800 280 6933 Email nsales ramcoi com ...

Page 30: ...lete 2 Installation Install the sensor and connect the cables according to the installation and wiring methods 3 1 Installation Method 3 2 Wiring Connection Diagram 3 Power ON Turn ON the power supply and confirm that the digital display of the sensor is displayed and laser beams are output from the sensor 4 Laser spot check Check whether the laser spot beam of the sensor is irradiated on the work...

Page 31: ...essary function settings according to application 5 1 List of Setting Items 7 Threshold judgment Perform teaching using the master workpiece It is also possible to set threshold values 5 9 Sensing Output Setting Teaching 8 Start measurement Measurement is started Check the measured values and indicators on the digital display 4 2 Operation Check 2 2 Description of Parts 9 Fine adjustment Perform f...

Page 32: ... the sensor every second Check the spot beam and adjust the beam axis When the emitted beam spot check mode is used sensing objects cannot be measured By holding down the UP key for 3 seconds or longer while the emitted beam spot check mode is selected you can return to the measurement display The display automatically returns to the measurement display when 2 minutes elapse after the sensor is se...

Page 33: ...he teaching indicator is lit and tch 2 is displayed on the digital display every 1 5 seconds 3 Insert a sensing object and press the TEACH key again The intermediate value between the values measured by the 1st teaching and 2nd teaching will be set as a threshold and teaching will be completed 4 1 Basic Setup Procedure WUME HGF1UM 2 4 5 Ramco Innovations www ramcoi com Got Questions Phone 800 280 ...

Page 34: ...t amount or if stable sensing cannot be performed Hard will be displayed Re examine the positional relationship between the background object and the measured object and perform teaching again Even when the difference between the teaching results is less than the shift amount or if the stable sensing cannot be performed the intermediate value between the two sensing results is set as the threshold...

Page 35: ...Setting 1 Check that the output operation indicator on the digital display is unlit 2 Insert a sensing object Check that the measured value on the digital display fluctuates 3 If the measured value falls within the range of the threshold set in 4 1 3 2 point Teaching Normal Sensing Mode the output operation indicator will light up 4 2 Operation Check WUME HGF1UM 2 4 7 Ramco Innovations www ramcoi ...

Page 36: ...4 2 Operation Check 4 8 WUME HGF1UM 2 Ramco Innovations www ramcoi com Got Questions Phone 800 280 6933 Email nsales ramcoi com ...

Page 37: ...on Setting 5 16 5 9 Sensing Output Setting Teaching 5 17 5 9 1 Normal Sensing Mode 5 18 5 9 2 Window Comparator Mode 5 21 5 10 Analog Output Setting 5 27 5 11 Analog Scaling Setting 5 28 5 12 Hysteresis Setting 5 32 5 13 Shift Amount Setting 5 33 5 14 External Input Setting 5 34 5 14 1 Zero Setting 5 34 5 14 2 Teaching 5 35 5 14 3 Emission Stop 5 35 5 15 Timer Setting 5 37 5 16 Timer Time Setting ...

Page 38: ...old fine adjustment No Setting item Display screen Function Reference page Measurement display 1 Threshold fine adjustment Used to make fine adjustment of the threshold P 5 6 Threshold selectable No Setting item Display screen Function Reference page Measurement display 1 Threshold selectable Used to select either threshold 1 or threshold 2 for adjustment When set to the window comparator mode Thr...

Page 39: ...Setting item Display screen Function Reference page Measurement display 1 Zero set setting Used to forcibly set the measured value to zero P 5 10 2 Zero set clearing Used to clear the zero setting Default 0 oFF P 5 11 Key lock function No Setting item Display screen Function Reference page Measurement display 1 Key lock setting Used to disables key operation P 5 13 5 1 List of Setting Items WUME H...

Page 40: ... 5 27 5 Analog scaling setting Used to set optional two points as the upper limit value and the lower limit value for performing two point correction on the analog output before data is output Set the measured value A as the lower limit value and the measured value B as the upper limit value Measured value A default 0 measured value B default 3 000 P 5 28 6 Hysteresis setting Used to set the hyste...

Page 41: ...ion when a measurement error occurs insufficient light intensity saturation of light intensity out of measurement range Default oFF P 5 41 12 ECO setting Used to turn OFF the digital display to save electricity when not operating Default oFF P 5 43 13 Reset setting Used to reset all the settings of this product to the factory default settings Default no P 5 44 5 1 List of Setting Items WUME HGF1UM...

Page 42: ...lue is set as a new threshold value and the screen returns to the measurement display Holding down the UP key or DOWN key will make the threshold value change faster Setting item Set value Default value Threshold fine adjustment When the zero set is cleared 250 to 3 000 Note 1 1 000 Threshold fine adjustment When the zero set is set 2 750 to 2 750 Note 2 Note 1 The settable maximum and minimum val...

Page 43: ...d then the screen will automatically return to the measurement display 2 When adjusting the threshold value just switched over press the UP key or DOWN key on the measurement display and adjust the threshold value After adjusting the threshold value to a desired value press the TEACH key to set the new threshold value The value for the threshold value 2 cannot be smaller than that for the threshol...

Page 44: ... value 1 1_SL 2 750 to 2 750 Note 2 1 000 Threshold value 2 2_SL 2 000 Note 1 The settable maximum and minimum values of the threshold are affected by the hysteresis setting Note 2 The settable maximum and minimum values of the threshold are affected by the zero set distance and the hysteresis setting 5 3 Threshold Selectable 5 8 WUME HGF1UM 2 Ramco Innovations www ramcoi com Got Questions Phone 8...

Page 45: ...y Function Hold function release Used to release the hold state and output the current measured value Peak hold Used to output the maximum value of the measured value Bottom hold Used to output the minimum value of the measured value If you do not make key operation for 3 seconds after selecting a function the changed function is set as a new function and the screen returns to the measurement disp...

Page 46: ...et to zero Depending on where the zero set is set the display value for the sensing location changes 5 5 1 Zero Set Setting 1 Simultaneously hold down the UP key and DOWN key for 3 seconds 0 is displayed on the digital display and when the keys are released 0 flashes three times to indicate that the setting has been completed When the zero set setting is enabled the zero set indicator lights up 5 ...

Page 47: ...led the held measured value is reset making it impossible to set the zero set function When an error occurs the zero set setting cannot be made The zero set function can also be set using an external input For detailed setting procedure refer to 5 14 External Input Setting 5 5 2 Zero Set Clearing 1 While the zero set setting is enabled simultaneously hold down the UP key and DOWN key for 6 seconds...

Page 48: ...et value Default value Zero setting Zero set setting 0 Zero set clearing 0 oFF 0 oFF 5 5 Zero Set Function 5 12 WUME HGF1UM 2 Ramco Innovations www ramcoi com Got Questions Phone 800 280 6933 Email nsales ramcoi com ...

Page 49: ...ing has been completed Press the UP key or DOWN key while the key lock setting is enabled and the current threshold value will be displayed If you press the TEACH key while the key lock setting is enabled Loc will be displayed on the digital display However in the window comparator mode you can switch the threshold value by holding down the TEACH key 5 6 2 Key Lock Release 1 While the key lock set...

Page 50: ...Set value Default value Key lock Key lock setting Lc on Key lock release Lc oF Lc oF 5 6 Key Lock Function 5 14 WUME HGF1UM 2 Ramco Innovations www ramcoi com Got Questions Phone 800 280 6933 Email nsales ramcoi com ...

Page 51: ... Setting the response time to a large value slow enables the sensor to be less influenced by sudden changes or similar events Hold down the DOWN key for 3 seconds or longer on the setting screen and the setting change is suspended and the screen returns to the measurement display Setting item Set value Default value Response time setting 35 100 300 2 000 100 5 7 Response Time Setting WUME HGF1UM 2...

Page 52: ...state Control output OFF Control output ON Setting method Hold down the DOWN key for 3 seconds or longer on the setting screen and the setting change is suspended and the screen returns to the measurement display The output operation indicator lights up when the control output is ON and goes out when the control output is OFF Setting item Set value Default value Output operation setting Light ON L...

Page 53: ...method Hold down the DOWN key for 3 seconds or longer on the setting screen and the setting change is suspended and the screen returns to the measurement display Setting item Sensing output setting Teaching method Default value Sensing output setting Normal sensing mode 2 point teaching Limit teaching Window comparator mode 1 point teaching 2 point teaching 3 point teaching 5 9 Sensing Output Sett...

Page 54: ...e Limit Teaching 2 point Teaching Overview This method is to perform teaching on the reference plane of two sensing objects and to set the intermediate value of the teaching results as the threshold value For setting procedure refer to 4 1 3 2 point Teaching Normal Sensing Mode Limit Teaching Overview This method is to perform teaching on the reference plane of sensing objects and to set the value...

Page 55: ...he standard 4 If the difference between the teaching results for the background object and the sensing object is equal to or larger than the shift amount good will be displayed on the digital display Then the desired threshold value is displayed and the teaching indicator turns OFF 5 9 Sensing Output Setting Teaching WUME HGF1UM 2 5 19 Ramco Innovations www ramcoi com Got Questions Phone 800 280 6...

Page 56: ... and the measured object and perform teaching again Even when the difference between the teaching results is less than the shift amount or if the stable sensing cannot be performed the intermediate value between the two sensing results is set as the threshold value 5 9 Sensing Output Setting Teaching 5 20 WUME HGF1UM 2 Ramco Innovations www ramcoi com Got Questions Phone 800 280 6933 Email nsales ...

Page 57: ...old value 2 P 5 23 3 point teaching This method is to perform teaching for the reference plane of the sensing objects 1 2 and 3 and to set the threshold value 1 and threshold value 2 P 5 24 1 point Teaching Overview This method is to perform 1 point teaching on the distance from the reference plane of a sensing object and to set the value obtained by subtracting the shift amount from the teaching ...

Page 58: ...ll be set and teaching will be completed If the difference between the teaching results for the background object and the sensing object is equal to or larger than the shift amount good will be displayed on the digital display Then the desired threshold value is displayed and the teaching indicator turns OFF 5 9 Sensing Output Setting Teaching 5 22 WUME HGF1UM 2 Ramco Innovations www ramcoi com Go...

Page 59: ...ching Overview This method is to perform teaching for the reference plane of the sensing object 1 and sensing object 2 respectively and to set the threshold value 1 and threshold value 2 1 With the sensing object 1 inserted press the TEACH key Teaching for the first point will be executed and the teaching indicator will be lit 5 9 Sensing Output Setting Teaching WUME HGF1UM 2 5 23 Ramco Innovation...

Page 60: ...e teaching results is less than the shift amount or if stable sensing cannot be performed Hard will be displayed Check the positional relationship between the sensing object 1 and sensing object 2 and perform teaching again 3 point Teaching Overview This method is to perform teaching for the reference plane of the sensing object 1 sensing object 2 and sensing object 3 respectively Here we call tea...

Page 61: ...ayed on the digital display every 1 5 seconds 3 Insert the sensing object 2 and press the TEACH key again Teaching for the second point will be executed 4 tch 3 will be displayed on the digital display every 1 5 seconds 5 9 Sensing Output Setting Teaching WUME HGF1UM 2 5 25 Ramco Innovations www ramcoi com Got Questions Phone 800 280 6933 Email nsales ramcoi com ...

Page 62: ...ount good will be displayed on the digital display Then the desired threshold value is displayed and the teaching indicator turns OFF If the difference between the teaching results is less than the shift amount or if stable sensing cannot be performed Hard will be displayed Check the positional relationship among the sensing objects 1 to 3 and perform teaching again 5 9 Sensing Output Setting Teac...

Page 63: ...nalog current output 4 to 20 mA Outputs a current according to the measured value Setting method Hold down the DOWN key for 3 seconds or longer on the setting screen and the setting change is suspended and the screen returns to the measurement display Setting item Set value Default value Analog output setting Analog voltage output v out Analog current output I out v out 5 10 Analog Output Setting ...

Page 64: ...outputs 0 V and the value that outputs 5 V and adjust the analog voltage output slope The output value for the analog output that is outside the measurement range is a fixed value Less than 200 mm 0 V More than 3 300 mm 5 2 V When the analog output is within the measurement range the output value is limited to 5 1 V and any value exceeding this value is not output Analog current output 4 mA to 20 ...

Page 65: ... 0 mA More than 3 300 mm 20 8 mA When the analog output is within the measurement range the output value is limited to 20 4 mA and any value exceeding this value is not output 5 11 Analog Scaling Setting WUME HGF1UM 2 5 29 Ramco Innovations www ramcoi com Got Questions Phone 800 280 6933 Email nsales ramcoi com ...

Page 66: ... Setting method Measured value A lower limit setting 5 11 Analog Scaling Setting 5 30 WUME HGF1UM 2 Ramco Innovations www ramcoi com Got Questions Phone 800 280 6933 Email nsales ramcoi com ...

Page 67: ...han the measured value A Setting item Set value Setting range Default value Analog scaling Measured value A A SCA 0 V 4 mA 0 to 2 999 0 Measured value B A SCB 5 V 20 mA 250 to 3 000 3 000 5 11 Analog Scaling Setting WUME HGF1UM 2 5 31 Ramco Innovations www ramcoi com Got Questions Phone 800 280 6933 Email nsales ramcoi com ...

Page 68: ...greater than half of the shift amount The hysteresis cannot be set to a value that is equal to or greater than the difference between the maximum displayable measured value in consideration of the zero set setting state and the threshold value When making zero set setting set the threshold value and then reset the hysteresis value as necessary Setting item Set value Default value Hysteresis 1 to 1...

Page 69: ... executed Setting method It cannot be set to a value that is equal to or less than twice the hysteresis If you keep holding down the UP key or DOWN key the shift amount changes faster Setting item Set value Default value Shift amount 2 to 3 000 60 5 13 Shift Amount Setting WUME HGF1UM 2 5 33 Ramco Innovations www ramcoi com Got Questions Phone 800 280 6933 Email nsales ramcoi com ...

Page 70: ...ction L oF 0SEt 5 14 1 Zero Setting This function is used to forcibly set the measured value to zero Using the external input keep the zero set to ON for 15 ms or longer and then change it from ON to OFF to execute zero setting ON When changing the zero set from ON to OFF turn the external input ON and after an elapse of 1 000 ms execute zero setting OFF The timing chart for setting or clearing th...

Page 71: ...input in the same manner as when the TEACH key is pressed For details on teaching refer to 5 9 Sensing Output Setting Teaching The timing chart for executing teaching using the external input is as shown in the following diagram Limit teaching cannot be executed by the external input alone Teaching using the external input is not accepted in the PRO mode 5 14 3 Emission Stop This setting is used t...

Page 72: ...learing the emission using the external input is as shown in the following diagram If the external input time is short the lit unlit state of the indicator may not match the emission state When emission stop is performed during teaching a teaching error occurs 5 14 External Input Setting 5 36 WUME HGF1UM 2 Ramco Innovations www ramcoi com Got Questions Phone 800 280 6933 Email nsales ramcoi com ...

Page 73: ...lds the ON output for the timer s time and then outputs OFF output When the timer is set or the timer s time is changed during output delay operation the changed set value is reflected when the output is changed next time Setting method If you do not make key operation for 3 seconds after changing the threshold value the changed value is set as a new threshold value and the screen returns to the m...

Page 74: ...time set for the OFF timing If the OFF duration is less than the timer s time the delay does not appear in the control output ON delay When the timer is set to ON delay the output is delayed for the timer s time set for the ON timing Therefore if the ON duration is less than the timer s time the delay does not appear in the control output 5 15 Timer Setting 5 38 WUME HGF1UM 2 Ramco Innovations www...

Page 75: ...ot and if the setting is changed from OFF to ON again while ON is held the ON time is extended by the timer s time 5 15 Timer Setting WUME HGF1UM 2 5 39 Ramco Innovations www ramcoi com Got Questions Phone 800 280 6933 Email nsales ramcoi com ...

Page 76: ...od The set timer time value is shared by all timer settings Hold down the DOWN key for 3 seconds or longer on the setting screen and the setting change is suspended and the screen returns to the measurement display Setting item Set value Default value Timer time setting 5 10 25 50 100 250 500 1 000 5 000 5 5 16 Timer Time Setting 5 40 WUME HGF1UM 2 Ramco Innovations www ramcoi com Got Questions Ph...

Page 77: ...g current output Outputs 20 8 mA when the sensing object is located farther away from the measuring range Outputs 0 mA if other measurement error occurs Hold last value Hold ON Digital display Displays the measured value right before a measurement error is detected as the last value Control output Outputs a value according to the last value Analog voltage output Analog current output Setting metho...

Page 78: ...Setting item Set value Default value Hold last value on 5 17 Hold Setting 5 42 WUME HGF1UM 2 Ramco Innovations www ramcoi com Got Questions Phone 800 280 6933 Email nsales ramcoi com ...

Page 79: ...ss any key while the digital display is OFF it turns ON again Setting method Hold down the DOWN key for 3 seconds or longer on the setting screen and the setting change is suspended and the screen returns to the measurement display Setting item Set value Default value ECO setting ECO OFF oFF ECO ON on oFF 5 18 ECO Setting WUME HGF1UM 2 5 43 Ramco Innovations www ramcoi com Got Questions Phone 800 ...

Page 80: ...ting Items Setting method Hold down the DOWN key for 3 seconds or longer on the setting screen and the setting change is suspended and the screen returns to the measurement display Setting item Set value Default value Reset setting Reset NG no Reset OK YES no 5 19 Reset Setting 5 44 WUME HGF1UM 2 Ramco Innovations www ramcoi com Got Questions Phone 800 280 6933 Email nsales ramcoi com ...

Page 81: ...nce 6 1 Maintenance and Inspection 6 2 6 1 1 Maintenance Precautions 6 2 6 1 2 Main Inspection Items 6 2 WUME HGF1UM 2 6 1 Ramco Innovations www ramcoi com Got Questions Phone 800 280 6933 Email nsales ramcoi com ...

Page 82: ...ble optimum use The main inspection items are as follows Is the product installation loose Have any input and output terminals become loose or come off Are there cracks in the cable Is the spot beam deviated from the set position Is the supplied power within the rated voltage range 24 VDC 10 Is the ambient temperature within the specified range 10 to 45 C Is the ambient humidity within the specifi...

Page 83: ...7 Troubleshooting 7 1 Solutions to Problems 7 2 7 2 Error Display 7 3 WUME HGF1UM 2 7 1 Ramco Innovations www ramcoi com Got Questions Phone 800 280 6933 Email nsales ramcoi com ...

Page 84: ...ny dirt that adheres to the light emitting and receiving windows of the sensor Dust dirt or other foreign matter adheres to the measurement object Remove any dust dirt or other foreign matter that adheres to the sensing object Dust grit or other substances are attached to the operating environment Use a dust collector or similar device to remove and prevent dust grit and other substances from flyi...

Page 85: ...e load During zero setting the measurement is not performed properly Check if the sensing distance to be set is within the specification range During teaching the measurement is not performed properly Check if the sensing distance to be set is within the specification range The beam emitting part or the beam receiving part is abnormal Turn the power OFF and then ON If the sensor does not recover a...

Page 86: ... MEMO 7 4 WUME HGF1UM 2 Ramco Innovations www ramcoi com Got Questions Phone 800 280 6933 Email nsales ramcoi com ...

Page 87: ...8 2 1 Products 8 5 8 2 2 Simple Mounting Bracket MS HG 01 Including two M3 screws with washer 8 6 8 2 3 Simple Mounting Bracket Attachment Diagram 8 7 8 3 I O Circuit Diagrams 8 8 WUME HGF1UM 2 8 1 Ramco Innovations www ramcoi com Got Questions Phone 800 280 6933 Email nsales ramcoi com ...

Page 88: ...ble Default Voltage output Analog voltage output Output range In normal condition 0 V to 5 V Possible to set the distance range Default 250 to 3 000 mm When alarm occurs Last value is held or the range is set to 0 V on the near point side and to 5 2 V on the far point side Output impedance 100 Ω Analog current output Output range In normal condition 4 mA to 20 mA Possible to set the distance range...

Page 89: ...e light emitting diode Lit while output is ON Teaching Yellow light emitting diode Lit while teaching is in progress Zero setting Yellow light emitting diode Lit while the zero set is enabled PRO mode Yellow light emitting diode Lit while the PRO mode is in progress Digital display Red light emitting diode Displays a code and 4 digit number Teaching function Normal sensing mode 2 point limit or wi...

Page 90: ...ess otherwise specified measurement conditions are as follows Power supply voltage of 24 VDC ambient temperature of 20 response time of 100 ms and measurement distance of 1 000 mm The target object is a 200 mm 200 mm white matte paper Perform measurement 30 minutes after turning on the power supply Note 2 Analog output is not included Note 3 When an object is detected the range of numerical values...

Page 91: ... Shapes and Dimensions 8 2 1 Products HG F13A A N HG F13A A P Units mm 8 2 Shapes and Dimensions WUME HGF1UM 2 8 5 Ramco Innovations www ramcoi com Got Questions Phone 800 280 6933 Email nsales ramcoi com ...

Page 92: ...mple Mounting Bracket MS HG 01 Including two M3 screws with washer Units mm 8 2 Shapes and Dimensions 8 6 WUME HGF1UM 2 Ramco Innovations www ramcoi com Got Questions Phone 800 280 6933 Email nsales ramcoi com ...

Page 93: ...8 2 3 Simple Mounting Bracket Attachment Diagram Units mm 8 2 Shapes and Dimensions WUME HGF1UM 2 8 7 Ramco Innovations www ramcoi com Got Questions Phone 800 280 6933 Email nsales ramcoi com ...

Page 94: ... N NPN type HG F13A A P PNP type Note 1 Insulate unused terminals to avoid error input or short circuit 8 3 I O Circuit Diagrams 8 8 WUME HGF1UM 2 Ramco Innovations www ramcoi com Got Questions Phone 800 280 6933 Email nsales ramcoi com ...

Page 95: ...Appendix Screen Transition List Screen Transition List App 2 WUME HGF1UM 2 App 1 Ramco Innovations www ramcoi com Got Questions Phone 800 280 6933 Email nsales ramcoi com ...

Page 96: ...Screen Transition List Screen Transition List App 2 WUME HGF1UM 2 Ramco Innovations www ramcoi com Got Questions Phone 800 280 6933 Email nsales ramcoi com ...

Page 97: ...ary 2023 Corrected caution notes to 1 4 Regulations and Standards Deleted Applicable regulations and certification in 8 1 Specifications Deleted Important Information about Order and Use of This Product WUME HGF1UM 2 Ramco Innovations www ramcoi com Got Questions Phone 800 280 6933 Email nsales ramcoi com ...

Page 98: ... MEMO WUME HGF1UM 2 Ramco Innovations www ramcoi com Got Questions Phone 800 280 6933 Email nsales ramcoi com ...

Page 99: ... MEMO WUME HGF1UM 2 Ramco Innovations www ramcoi com Got Questions Phone 800 280 6933 Email nsales ramcoi com ...

Page 100: ... https panasonic net id pidsx global Please visit our website for inquiries and about our sales network Panasonic Industrial Devices SUNX Co Ltd 2023 February 2023 WUME HGF1UM 2 Ramco Innovations www ramcoi com Got Questions Phone 800 280 6933 Email nsales ramcoi com ...

Reviews: