126
Chapter 7 Menu description tables
(continued)
7-8 VTR MENU
7-8-1 VTR FUNCTION
RC CHECK SW
R.REVIEW
RETAKE
For setting the operations of the unit by
using the REC check button on the remote
control unit.
R.REVIEW:
The rec-review operation is
performed.
RETAKE:
The retake operation is
performed, after which playback
is initiated automatically.
Item
Variable
range
Remarks
HUMID OPE
ON
OFF
For selecting whether or not to continue
operation when HUMID alarm state has
occurred.
ON:
Operation continues until tape slack is
detected even when the HUMID alarm
state has occurred during operation.
OFF:
Operation is stopped as soon as the
HUMID alarm state occurs.
If the HUMID alarm state occurs during
recording, the recording operation will
continue unless tape slack is detected
regardless of whether ON or OFF has been
selected as this item’s setting.
REC START
ALL
NORMAL
For selecting how recording start is to be
accepted.
PAUSE TIMER
10min
20min
30min
60min
For selecting the time during which REC/
PAUSE is to continue.
C U F
C U F
C U F
C U F
BATT NEAR END
ALARM
ON
OFF
For setting whether or not to output the
warning tone when the battery charge is
nearly depleted.
BATT REMAIN
FULL
100%
70%
For setting when the remaining charge
display bar on the LCD is to be displayed
when a digital battery is used.
70%:
A full charge is indicated with a 70%
display
100%:
A full charge is indicated with a 100%
display.
BATT NEAR END
CANCEL
ON
OFF
When this item is set to ON, the warning
tone and the warning display which are
being output can be canceled by pressing
the MODE CHECK button when the battery
charge is nearly depleted.
BATT END ALARM
ON
OFF
For setting whether or not to output the
warning tone when the battery charge is
depleted.
7-8-2 BATTERY/TAPE
Item
Variable
range
Remarks
BATTERY SELECT
PROPAC14
TRIMPAC14
HYTRON50
HYTRON120
DIONIC90
DIONIC160
NP-L7
ENDURA7
ENDURA10
ENDURA-D
PAG L95
BP-L65/95
NiCd14
TYPE A
TYPE B
For selecting the type of battery to be used.
The remaining charge is detected in
accordance with the battery which has been
selected.
The variable range is changed by the item
settings selected on the “7-8-3 BATTERY
SETTING1” and “7-8-4 BATTERY
SETTING2” menus.
The initial value for TYPE A is set to
DIONIC100 while the same for TYPE B is
set to HYTRON100.
O
BP-L65/95 indicates the BP-GL65/95
battery.
EXT DC IN
SELECT
AC_ADPT
PROPAC14
TRIMPAC14
HYTRON50
HYTRON120
DIONIC90
DIONIC160
NP-L7
ENDURA7
ENDURA10
ENDURA-D
PAG L95
BP-L65/95
NiCd14
TYPE A
TYPE B
For selecting the external power supply to
connect to the DC IN socket.
The variable range is changed by the item
settings selected on the “7-8-3 BATTERY
SETTING1” and “7-8-4 BATTERY
SETTING2” menus.
Analog voltage is displayed on the
viewfinder screen.
O
BP-L65/95 indicates the BP-GL65/95
battery.
C U F
C U F
C U F
C U F
C U F
C U F
TAPE REMAIN/
∫
5min/
∫
3min/
∫
For setting the time of each segment (
∫
)
that makes up the remaining time display
bar on the LCD.
5min:
Each segment denotes a remaining
time of 5 minutes.
3min:
Each segment denotes a remaining
time of 3 minutes.
TAPE NEAR END
ALARM
ON
OFF
For setting whether or not to output the
warning tone when the tape is nearly at its
end.
TAPE NEAR END
TIME
3min
2min
For setting the remaining tape time at which
to sound the warning that the tape has only
the designated amount of time (2min. or
3min.) remaining.
TAPE END ALARM
ON
OFF
For setting whether or not to output the
warning tone when the tape reaches the
end.
C U F
C U F
C U F
C U F
The underlining in the variable range column indicates the setting in the preset
mode.
COMPRESSION
MODE
NORMAL
DARK
For selecting the DVCPRO compression
mode.
O
This is enabled when the recording format
is set to 720P.
NORMAL:
Normal shooting shall be executed in this
mode.
DARK:
Distortion of compressed video images
that may occur at dark parts on the video
images can be suppressed in this mode.
Distortion of compressed video images on
other parts may increase.
C U F
01.AJ-HDX900̲P̲E(VQT0X86-1)̲E 06.10.19 3:34 PM ページ126
Downloaded From CamcorderManual.com Panasonic Manuals