Indication contents
Lock search history indication of camera
Display the camera system and fan system error code for three histories saved in EEPROM.
The error code contents which are displayed
End method of operation
Touch the [ BAK ] of LCD to exit the lock search and error history indication, and then POWER OFF.
6.3 Power ON Self Check Result Display
Touch the [ 5 ] of LCD, select Power ON self check result display.
Operation specifications
Indication contents
Power ON self check result display
Function to diagnose correct function of the device and interface between devices result display.
Display the following communication test result.
Error code
Description
Problematic Parts
51
Focus control is abnormal
LENS UNIT
52
Zoom control is abnormal
2ND STEPPING MOTOR / LENS UNIT
53
OIS lens control is abnormal LENS UNIT
54
Zoom control is abnormal (2) 3RD STEPPING MOTOR / LENS UNIT
55
Zoom control is abnormal (3) 4TH STEPPING MOTOR / LENS UNIT
72
Fan is abnormal
DC FAN MOTOR UNIT
Page 3 of 6