Aspect Ratio
16:9
Mask Number
1
Pan Angle
135°
Tilt Angle
10°
Aspect ratio
1(4:3)
Mask Number
1
Mask Width
0x050
Mask Height
0x03C
Mask transparency
1
Y/Pb/Pr
0x40 / 0x40 / 0x40
Pan Angle*
135°
Tilt Angle*
45°
Function Descriptions
Usage: Sets the mask position mainly according to the
optical.
Note:
Set the mask size to sufficiently cover the mask
object. In addition, ensure that the settings are
set on the WIDE end.
x
Mask width
Note: Set using a pan angle range of 0°-360° and
a tilt angle range of –180°-180°. (Refer to the
diagram below)
The angle is displayed as 12 bits and
divided into 4-bit units when increased by a
magnification of 10.
In addition, when setting a negative tilt angle set
the tilt angle code bit f to 1.
Example) Setting the mask angle according to the
following parameters
Mask height
y
Example) Setting the mask position according to the
following parameters
*For PAN Angle and TILT Angle, the angle parameters
that were sent in advance to the camera by PAN/TILT
Degree Command will be reflected automatically.
Pan Angle:
1350
→
0x546
→
q = 5, r = 4, s = 6
Tilt angle sign bit:
If the tilt angle is positive
→
x = 0
Tilt Angle:
100
→
0x064
→
t = 0, u = 6, v = 4
Transmitted according to the following.
A0 10 11 00 01 05 04 06 00 06 04 CS FF
According to the setting above, if the tilt angle only is
set to -10 degrees the following codes are transmitted.
A0 10 11 00 01 05 04 06 10 06 04 CS FF
TILT =
−
90˚
Setting Procedures
1. Mask Position (width and height) Settings
(Area Mask Position Center Set)
A0 10 0A 01 01 00 05 00 00 03 0C 01 40 40 40
CS FF
2. Setting Mask ON (Area Mask ON)
A0 10 01 01 01 CS FF
PAN = 0˚ / 360˚
TILT = 0˚
PAN = 270˚
PAN = 90˚
PAN = 180˚
TILT = +/
−
180˚
Setting the Mask Angle
The following commands are valid for changing Pan/
Tilt Angle of the pre-registered masks.
Area Mask Degree Set
Command: A0 10 11 0p 0q 0r 0s 0t
fu 0v 0w CS FF
TILT = 90˚
Parameter:
p
Aspect Ratio ( 0: 16:9 1: 4:3 )
q
Mask Number (No. 1-15)
rst
Pan Angle (0°-360°)
f
Tilt angle sign bit
uvw
Tilt Angle (0°-180°)
Usage: Sets the angle of the specified mask numbers.
−