background image

19

3.2 Mounting on a wall

Use the two wall mount brackets and eight screws (for fixing the wall mount brackets to the 
Ethernet Switch) supplied with the mount brackets to fix the mount brackets to the four 
holes on each side of the Ethernet Switch. 
Then secure the device securely to the wall surface with the screws which the customer has 
prepared.

Right side

Left side

Screw holes for wall mount brackets

Summary of Contents for GA-MLi8TPoE+ Series

Page 1: ...rs are not covered by the warranty C1119 40222 Printed in Japan GA MLi8TPoE Model No PN260893H TH PN260893H MY PN260893H ID PN260893H SG PN260893H NZ The instruction manuals Menu Version CLI Version Web Version latest firmware and SDN application ZEQUO assist Plus can be downloaded from the following URL https panasonic co jp ew pewnw english datadownload index html 2 12 7 Higashi Shimbashi Minato...

Page 2: ... 1 3 Accessories 1 4 Basic operation 2 Part Names and Functions 2 1 LED display change 2 2 PoE power supply function 3 Installation and Configuration 3 1 Grounding Cable Connection 3 2 Mounting on a wall 3 3 Mounting to rack PN260893H NZ only 3 4 Configuration of IP address Basic Troubleshooting 3 7 8 8 9 11 11 12 15 17 18 18 19 20 21 23 ...

Page 3: ...ad to fire electric shock and or equipment failure Do not damage the power cord Do not bend too tightly stretch twist bundle with other cord pinch put under a heavy object and or heat it Damaged power cord could lead to fire short and or electric shock Do not unplug nor plug in the power plug with wet hands Deviation could lead to electrical shock and or equipment failure Do not insert or drop for...

Page 4: ...e bundled power cord AC 100 240 V specifications Deviation could lead to electric shock malfunction and or equipment failure Unplug the power cord in case of equipment failure Deviation such as keep connecting for a long time could lead to fire Be sure to connect the ground cable Otherwise this might cause electrical shocks misoperations and malfunctions Connect the Ethernet Switch via the supplie...

Page 5: ...site which has the requisite items listed on it When using this Ethernet Switch to design systems use it after applying appropriate measures such as setting up redundant configurations Communication failures might be generated due to causes such as malfunctions or misoperations while the Ethernet Switch is being used When using this Ethernet Switch for applications which require extremely high rel...

Page 6: ...g the installation area transporting and attaching and removing attachment brackets etc Connecting and disconnecting twisted pair cables fiber optic cables SFP modules and console cables Attaching and removing power cords Operating LED display change buttons Deviation could lead to injuries or burns etc because of high temperatures Do not connect any other devices except for 10BASE T 100BASE TX 10...

Page 7: ... sunlight Possible condensation High low temperature exceeding the specifications environment Strong vibration and or strong shock Failure to satisfy the conditions above may result in a fire electric shock equipment failure and or malfunction Such events are not covered by the warranty If it is used beyond the operating environmental temperatures then the protective devices will start working and...

Page 8: ... verifications of the Ethernet Switch Remotely configure the PoE settings for each port Ports 1 to 8 The connection status for each port is detected by the power saving mode and it can suppress the power consumption to required volumes when not linked up Factory default disabled Rapid Spanning Tree Protocol is supported allowing to build a system with redundancy The IEEE802 1p compatible QoS funct...

Page 9: ...me transmission Link Aggregation IEEE802 3ad Configurable up to 5 groups Max 8 ports per group VLAN IEEE802 1Q tagging VLAN protocol compatible Max 256 groups including the default VLAN Port based VLAN Internet Mansion function QoS IEEE802 1p compatible Supports 8 priority queues Management method ZEQUO assist Plus SNMP v1 v2c v3 Telnet SSH v2 Console WEB control screen PoE Power supply function P...

Page 10: ...Switch power will be shut off Others STP RSTP MSTP Supports the IEEE802 1X authentication MAC based port based MAC authentication WEB authentication Triple authentication STEP authentication IEEE802 1X supplicant Port monitoring Ring protocol IGMP snooping Loop detection shutoff function Storm control DSCP mapping function Login RADIUS function DHCP client function PoE scheduler function PoE auto ...

Page 11: ...0 V 50 60 Hz When power is supplied all the LEDs are turned ON Then POWER LED Power lights in green STATUS ECO LED Status ECO mode lights in orange and self diagnosis of hardware is executed On completion of self diagnosis POWER LED Power STATUS ECO LED Status ECO mode and TEMP LED Temperature sensor light in green and the Ethernet Switch starts operation as an Ethernet Switch As this Ethernet Swi...

Page 12: ...ound terminal screw 10 100 1000BASE T ports ports 1 10 Ports 1 to 8 can supply PoE power confirming with IEEE802 3at af Devices such as 10 100 1000BASE T terminal hub repeater bridge and Ethernet Switch can be connected to this port Install the device so that the length of twisted pair cable CAT5e or above becomes 100m or less SFP extension slot ports 9 10 Install SFP module It becomes exclusive u...

Page 13: ...y is exceeding the upper limit or the total power supply of the Ethernet Switch is exceeding 62 W TEMP LED Temperature sensor Green Light The system is normally operating Orange Blink The temperature exceeded the set threshold of the internal temperature sensor Set threshold of the internal temperature sensor 74 C factory default FAN Fan sensor LED Green Light The system is normally operating Oran...

Page 14: ...en Light Link is established at full duplex Off Link is established at half duplex or no device is connected Green Light Orange Blink Off LOOP HISTORY Green Light Loop has been detected within the last 3 days Off No loop detection history It is shut off via the loop detection and shutoff function storm control or the BPDU guard PoE are being supplied power Power is not being supplied or the PoE re...

Page 15: ...r one minute or longer the mode automatically returns to a Base mode Status mode or ECO mode The Base mode is maintained even after the power is turned OFF Indication on the front panel and LED lamps You can display the following items using the LED display switch button Display for the connection with a connected terminal Status mode Display for the 1000 Mbps transmission rate GIGA mode Display f...

Page 16: ...mode The Base mode is maintained even after the power is turned OFF LED lamps for each mode and LED lamps for ports 1 to 10 correspond as shown in Table 1 see page 14 Turns on the port LED with a orange light when a loop occurs in the corresponding port The Loop shutoff mode has the following 2 types of modes Block mode factory default When loops are detected the port statuses are automatically bl...

Page 17: ... 62 W 1 When configured IEEE802 3at factory default Exceeds 15 4 W when configured IEEE802 3af When the requested power supply for the Ethernet Switch is exceeded and it gets overloaded the power supply to the low priority ports is stopped and the port LEDs right of the ports whose power supply have been stopped blink orange The priority settings for the power supply can be set and changed from th...

Page 18: ... cable must be no less than 18 AWG and the length is 50 cm 3 The ground installed screw shall comply with 3 5mm minimum in nominal thread diameter and engage at least two complete threads into metal chassis with appropriate fixing hardware like washer 4 The grounding cable shall not be removed during normaI operation servicing or maintenance 5 Installation steps Step 1 Ensure the detachable power ...

Page 19: ... brackets to the Ethernet Switch supplied with the mount brackets to fix the mount brackets to the four holes on each side of the Ethernet Switch Then secure the device securely to the wall surface with the screws which the customer has prepared Right side Left side Screw holes for wall mount brackets ...

Page 20: ... mount brackets and eight screws for fixing the rack mount brackets to the Ethernet Switch supplied with the mount brackets to fix the mount brackets to the four holes on one side of the Ethernet Switches Then use the two connection brackets and eight screws for fixing the connection brackets supplied with the mount brackets to securely fix the connection brackets to the connection screw holes on ...

Page 21: ...ng command Screen 3 enable configure config interface vlan 1 config if ip address 192 168 1 254 255 255 255 0 5 Enter the following command to save the setting config if exit config exit copy running config startup config 6 Once the following screen is displayed enter Y and the settings will be saved Screen 4 Confirm that the settings have been normally saved Screen 5 7 After configuring start wit...

Page 22: ...fig interface vlan 1 GA MLi8TPoE config if ip address 192 168 1 254 255 255 255 0 GA MLi8TPoE config if GA MLi8TPoE Product Number PN260893H Firmware Version x x x xx MAC Address 00 50 40 xx xx xx Serial Number xxxxxxxxxxx UserName manager Password GA MLi8TPoE enable GA MLi8TPoE configure GA MLi8TPoE config interface vlan 1 GA MLi8TPoE config if ip address 192 168 1 254 255 255 255 0 GA MLi8TPoE c...

Page 23: ...0BASE TX or 1000BASE T standard Auto negotiation may have failed Check the port settings of this Ethernet Switch or the terminal settings Is the correct Port LED display mode selected using the LED display switch button The Port LED left lights in orange Loop is occurring By removing the loop orange LED will be turned off LOOP HISTORY LED Blinks in green This is to notify that there is a port in w...

Page 24: ... cable RJ45 8 8 used Is the cable connected to the port 1 8 that supports PoE power supply Ensure that either the port alone or the entire equipment is not overloaded Is the Powered Device connected to the port compliant with the IEEE802 3at standard or IEEE802 3af standard Is the upper threshold of the power supply manually Manual set in the range of 15600 30000 mW When power is being supplied to...

Reviews: