Basic Instructions for the Use of This Product

  For inspection and/or repair, consult the retailer.

  Use commercial power supply from a wall socket, which is close and easily accessible to this 

Ethernet Switch.

  Unplug the power cord when installing or moving this Ethernet Switch.

  Unplug the power cord when cleaning this Ethernet Switch.

  Use this Ethernet Switch within the specifications. Deviation could lead to malfunction.

  Do not touch the twisted pair cable modular metal terminals which are connected to RJ45 

connectors (twisted pair ports) or the connectors, nor place them near electrically-charged 
objects. Static electricity could lead to equipment failure.

  Do not put the modular plug of the connected twisted pair cable on objects that can carry 

static charge, such as carpet. Do not place it in the proximity. Static electricity could lead to 
equipment failure.

  Do not put a strong shock, including dropping, to this Ethernet Switch. Deviation could lead 

to equipment failure.

  Do not store and/or use this Ethernet Switch in the environment with the characteristics listed 

below.

  (Store and/or use this Ethernet Switch in the environment in accordance with the 

specification.)

-  High humidity. Possible spilled liquid (water).
-  Dusty. Possible static charge (such as carpet).
-  Under direct sunlight.
-  Possible condensation. High/low temperature exceeding the specifications environment.
-  Strong vibration and/or strong shock.

  Please use this Ethernet Switch in place where ambient temperature is from 0 to 50

°

C.

     Failure to satisfy the conditions above may result in a fire, electric shock, equipment failure, 

and/or malfunction. Such events are not covered by the warranty.   

     Do not block the ventilator of the Ethernet Switch.
     Blocked ventilator induces the heat accumulation inside, causing equipment failure and/or 

malfunction.

  If used at a temperature out of the operating temperature range, the protection equipment 

becomes activated and the power supply stops. 

  When using two Ethernet Switches, do not stack them. When you place them side by side, 

allow for a space of 20 mm or more between them.

  When mounting Ethernet Switch to rack, leave a minimum of 20 mm space between them.

1. Please note that Panasonic shall not bear any liability whatsoever for any damages 

(this shall include, but is not limited to, lost earnings, lost opportunities, etc.)  

which were generated in relation to damages caused by operations and usage, 
or the inability to use this Ethernet Switch, whereby the customer does not follow 
this Installation Guide.

2. The contents described in this document may be changed without prior notice. For the 

latest version, please refer to the Panasonic website.

3. For any question, please contact the retailer where you purchased the product.

6

Summary of Contents for GA-AS4TPoE+ Series

Page 1: ... Switch by customers are not covered by the warranty I0916 50822 Printed in Japan GA AS4TPoE PN25048 TH PN25048 MY PN25048 ID PN25048 SG PN25048 NZ Model No The instruction manuals Web Version latest firmware and SDN application ZEQUO assist Plus can be downloaded from the following URL https panasonic co jp ew pewnw english datadownload index html 2 12 7 Higashi Shimbashi Minato ku Tokyo Japan 10...

Page 2: ...ct 1 Product Outline 1 1 Features 1 2 Specifications 1 3 Accessories 1 4 Basic operation 2 Part Names and Functions 3 Installation and Configuration 3 1 Grounding Cable Connection 3 2 Mounting to rack 3 3 Configuration of IP address Basic Troubleshooting 3 6 7 7 8 9 9 10 12 12 13 14 16 ...

Page 3: ...fire electric shock and or equipment failure Do not connect equipments other than 10BASE T 100BASE TX 1000BASE T to twisted pair port When connecting to a 10BASE T device use a Cat5 or above cable Deviation could lead to fire electric shock and or equipment failure Do not place this Ethernet Switch in harsh environment such as near water high humid and or high dust Deviation could lead to fire ele...

Page 4: ...port Deviation could lead to electric fire shock and or malfunction If the STATUS Status LED blinks in orange unplug the power cord since this is a malfunction Deviation such as keep connecting for a long time could lead to fire Handle the Ethernet Switch carefully so that fingers or hands may not be damaged by twisted pair port or power cord hook block When connecting IEEE802 3at enabled receivin...

Page 5: ... decrease due to the age related degradation etc of components It is recommended that this Ethernet Switch be replaced about five years after it has been installed Be careful in regards to environmental restrictions whereby the Ethernet Switch can be used Please isolate the business power lines and communication lines Isolate distribution lines and other distribution lines and low current power li...

Page 6: ...et Under direct sunlight Possible condensation High low temperature exceeding the specifications environment Strong vibration and or strong shock Please use this Ethernet Switch in place where ambient temperature is from 0 to 50 C Failure to satisfy the conditions above may result in a fire electric shock equipment failure and or malfunction Such events are not covered by the warranty Do not block...

Page 7: ... be made The factory default is for ports 1 to 4 to have MDI X be fixed Equipped with IEEE802 3az LPI compatible Energy Efficient Ethernet functions hereinafter EEE and if data is transmitted when linked up the energy efficient state will be moved to whereas each port can suppress power consumption Automatically detects the connection states via the equipped energy efficiency mode and suppresses p...

Page 8: ...upports 4 priority queues Management method WEB control screen ZEQUO assist Plus Power supply function Ports 1 to 4 support the IEEE802 3at compatible power supply function Maximum power supply 30 W per port 62 W in total Power supply method Altervative A Using idle line 1 2 3 6 Others Port Monitoring Storm control Power supply AC 100 240V 50 60 Hz 1 7 A Power consumption Normally Max 77 1 W 6 3 W...

Page 9: ...ently the POWER power LED lights up green and the STATUS status LED lights up orange and the hardware runs a self diagnostic When it is finished both the the POWER power LED and STATUS status LED light up green and it operates as a Ethernet Switch As this Ethernet Switch succeeds in communicating with a terminal connected to each port LED of the port lights up When the terminal is not operating no...

Page 10: ...e ground terminal screw 10BASE T 100BASE TX 1000BASE T port ports 1 6 Connect 10BASE T 100BASE TX 1000BASE T terminals hubs repeaters bridges and Ethernet Switches Install the device so that the length of the twisted pair cables CAT5e or above will be 100 m or less PoE power supply ports ports 1 4 The port can supply PoE power conforming with IEEE802 3at Connect a Powered Device conforming with IE...

Page 11: ...M PoE limit LED Off Supplies power in a range of 0 55 W Green Light Supplies power in a range of 55 W 62 W Green Blink When the requested power supply capacity exceeds 62 W overload of the device overall Port LED Left LINK ACT ports 1 6 LED Green Light Link is established Green Blink Data is being sent received Off No terminal is connected Port LED Right PoE ports 1 4 LED Green Light Power is supp...

Page 12: ...ounding cable must be no less than 18 AWG and the length is 50 cm 3 The ground installed screw shall comply with 3 5mm minimum in nominal thread diameter and engage at least two complete threads into metal chassis with appropriate fixing hardware like washer 4 The grounding cable shall not be removed while normal operating servicing or maintenance 5 Installation steps Step 1 Ensure the detachable ...

Page 13: ...kets and eight screws for fixing the rack mount brackets to the Ethernet Switch supplied with the mount brackets to fix the mount brackets to the four holes on one side of the Ethernet Switches Then use the two connection brackets and eight screws for fixing the connection brackets supplied with the mount brackets to securely fix the connection brackets to the connection screw holes on the front a...

Page 14: ...thin the broadcast domain In a few seconds the screen displays the list of detected Ethernet Switches Screen 2 4 From the list of the detected Ethernet Switches select a device that you want to configure In the Setting item field in the lower part of the screen configure Network setting Switch name and other items 5 Fill in the setting items and press the Setting execution button to display the co...

Page 15: ... Screen 3 Screen 4 For detailed configuration and management methods and the settings from the ZEQUO assist Plus and the Web screens please see the PDF version of the Operating Instructions on Panasonic s website ...

Page 16: ...ay be failing Set this device s port setting or the terminal s setting to half duplex Communication is slow Are the communication speed and mode settings correct If the proper communication mode signal cannot be obtained apply half duplex mode Please reconfirm Auto negotiation setting Is not the utilization ratio of the network to which this Ethernet Switch is connected too high Try separating thi...

Page 17: ...ded Is the Powered Device connected to the port compliant with the IEEE802 3at standard or IEEE802 3af standard Port LIM LED is blinking in green Ensure that the total power supply demand from PoE powered devices does not exceed 62 W When the power supply is suddenly shut off Confirm that a single port is not overloaded Port LED right is not blinking in Green or that the power supply capacity for ...

Reviews: