3.2 Mounting to rack (PN25048-NZ only)
13
Use the two 19-inch rack mount brackets and eight screws (for fixing the rack mount brackets
to the Ethernet Switch) supplied with the mount brackets to fix the mount brackets to the four
holes on each side of the Ethernet Switch. Then securely install the Ethernet Switch onto the
rack using the four screws (for a 19-inch rack mount) supplied with the mount brackets or the
screws supplied with the rack.
Up to two Ethernet Switches can be connected. When connecting two Ethernet Switches and
installing them onto a rack, use the two 19-inch rack mount brackets and eight screws (for fixing
the rack mount brackets to the Ethernet Switch) supplied with the mount brackets to fix the
mount brackets to the four holes on one side of the Ethernet Switches. Then use the two
connection brackets and eight screws (for fixing the connection brackets) supplied with the
mount brackets to securely fix the connection brackets to the connection screw holes on the
front and back panels, and then install the Ethernet Switches onto the rack.
Right side
Left side
Screw holes for fixing the 19-inch rack mount brackets
Front
Connection screw hole
Installation on a rack (one unit)
Installation on a rack (two coupled units)
Connection screw hole
19-inch rack mount brackets
Connection brackets
19-inch rack mount brackets
Back
Back
Front
Front
19-inch rack mount brackets