background image

1

InstructIon Manual

Digital Fiber Sensor

FX-100-Z

 Series

MEUEN-FX100Z V1.0

Thank you for purchasing products from Panasonic Electric Works SUNX 
Co., Ltd. Please read this Instruction Manual carefully and thoroughly for 
the correct and optimum use of this product. Kindly keep this manual in a 
convenient place for quick reference.

WARNING

 

Never use this product as a sensing device for personnel protection.

 

In case of using sensing devices for personnel protection, use prod-
ucts which meet laws and standards, such as OSHA, ANSI or IEC 
etc., for personnel protection applicable in each region or country.

1

cautIons

 

This product has been developed / produced for industrial use only.

 

Make sure that the power supply is off while wiring.

 

If a voltage exceeding the rated range is applied, or if an AC power 
supply is directly connected, the product may get burnt or damaged.

 

Short-circuiting the load or incorrect wiring may burn or damage the 
product.

 

Do not run the wires together with high-voltage lines or power lines 
or put them in the same raceway. This can cause malfunction due to 
induction.

 

Verify that the supply voltage variation is within the rating.

 

If power is supplied from a commercial switching regulator, ensure that 
the frame ground (F.G.) terminal of the power supply is connected to 
an actual ground.

 

If noise generating equipment (switching regulator, inverter motor, etc.) 
is used in the vicinity of this product, connect the frame ground (F.G.) 
terminal of the equipment to an actual ground.

 

Do not use during the initial transient time (0.5s) after the power sup-
ply is switched on.

 

You can extend the cable up to 100m max. with 0.3mm

2

 or more 

cable. However, in order to reduce noise, make the wiring as short as 
possible.

 

Make sure that stress is not applied to the sensor cable joint, e.g. by 
forcible bending or pulling.

 

● Take care that the product is not directly exposed to fluorescent lamp 

from a rapid-starter lamp, a high frequency lighting device or sunlight, 
etc. as it may affect the sensing performance.

 

This product is suitable for indoor use only.

 

Avoid dust, dirt, and steam.

 

Take care that the product does not come in contact with oil, grease, 
organic solvents, such as thinner, etc., strong acid or alkalines.

 

● This product cannot be used in an environment containing inflam

-

mable or explosive gases.

 

Never disassemble or modify the product.

 

EEPROM is adopted to this product. Teaching is limited to 100,000 
times because of the EEPROM's lifetime.

2

Part DEscrIPtIon

1

6

5

4

3

2

no.

Part

Description

1

Output indicator (orange)

Lit when output is active.

2

Mode key

 

Select mode

 

● Confirm settings

3

ON key / Set value UP key

 

Select settings in teaching mode

 

Increase set value

 

Select various other settings

4

OFF key / Set value DOWN key

Select settings in teaching mode

Decrease set value

Select various other settings

5

Green digital display

Threshold value

no.

Part

Description

6

Red digital display

Incident light intensity

3

MountInG

When using a DIn rail

You may break the spring hook if you do not follow the mounting 
instructions carefully.

How to mount the amplifier

1. 

Fit the spring hook on a 35mm DIN rail and 
push forward.

2. 

Slip the front part of the mounting section 
over the DIN rail and release.

1

2

35mm

How to remove the amplifier

1. 

Push the amplifier forward.

2. 

Lift up the front part of the amplifier.

1

2

When using screws with washers

Use M3 screws with washers to mount the 

amplifier.

Do not use a tightening torque of more than 0.5 

N•m or you may break the housing.

M3 screw

with washers

How to connect the fiber cable

Be sure to fit the attachment to the fibers first before inserting the fibers into 

the amplifier. For details, refer to the Instruction Manual enclosed with the 

fibers.

1. 

Snap the fiber lock lever down until it 

stops completely.

2. 

Slowly insert the fiber cables into the 

inlets until they stop (see note). 

If the fiber cables are not inserted until 

they stop, the sensing range reduces. 

Since a flexible fiber is easily bent, be 

careful when inserting it.

3. 

Return the fiber lock lever to the original 

position.

1

3

2

Fiber lock 

lever

Fiber

If the cable is a coaxial reflective type fiber, e.g. FD-G4 or FD-

FM2, insert the single-core fiber cable into the beam-emitting 

inlet “P” and the multi-core fiber cable into the beam-receiving 

inlet “D.” If they are inserted in reverse, the sensing perfor

-

mance will deteriorate.

Summary of Contents for FX-100-Z Series

Page 1: ...t and steam Take care that the product does not come in contact with oil grease organic solvents such as thinner etc strong acid or alkalines This product cannot be used in an environment containing inflam mable or explosive gases Never disassemble or modify the product EEPROM is adopted to this product Teaching is limited to 100 000 times because of the EEPROM s lifetime 2 Part DEscrIPtIon 1 6 5 ...

Page 2: ...run MoDE Digital display When you turn ON the power the product name is indicated in green and the emission frequency is indicated in red Then the device automatically switches into RUN mode in which the threshold value is displayed in green and the incident light intensity in red Power ON Emission frequency Product name RUN mode Incident light intensity Threshold value Automatic What appears on t...

Page 3: ...ttle margin between the theshold value and incident light intensity is al lowed for the environment when teaching 2 point teaching 2 point teaching is the most common teaching method and means the threshold value is taught using two points that correspond to the object present and object absent conditions Light ON or Dark ON is determined automatically for the output operation setting Output indic...

Page 4: ...n the threshold value follow up cycle is set the threshold value is adjusted according to the shift based on the incident light intensity detected However the threshold value is not stored GETA function note 4 5 Variations can be reduced by setting the present incident light intensity for each amplifier to a certain value For example if this value is set to 2 000 and the incident light intensity i...

Page 5: ... point Sampling in progress NPN output type High NPN output type Low 1 Depending on the threshold value output may turn ON OFF when emission is halted or released 2 When emission starts output operation is undetermined during the response time If the output signal is received by a PLC for example set the amplifier s timer to 20ms response time or greater Example For the FX 101q Z with emission fre...

Page 6: ...to another amplifier repeat steps 3 to 7 If the power is not turned on at the same time the setting con tents may not be copied To cancel the setting copy function of the master amplifier 1 While the slave side amplifier is disconnected turn on the power of the master side amplifier 2 Press MODE for 2s 12 QuIcK sEttInG FunctIon Simply by selecting a quick setting number which are listed in the tab...

Page 7: ...1 0 4 3 2 1 4 3 2 1 45 40 35 30 25 20 15 10 5 50 E_oF E_of LtcP Ltc Auto Eco LtcP Ltc Auto Eco ON OFF Code 1st digit 4th digit 3rd digit 2nd digit Output operation Timer see note Emission amount setting Emission frequency ECO External input Shift see note For differences between the conventional and modified units see unIt VErsIons on page 7 14 Error InDIcatIon If the follow error codes are displa...

Page 8: ...ansistor Maximum source current 100mA Applied voltage 30V DC or less between output and V Residual voltage 1 5V or less at 100mA source current output operation Light ON or Dark ON selectable short circuit protection Incorporated External input NPN output type NPN non contact input Signal condition High 8V to V DC or Open Low 0 to 2V DC Source current 0 5mA or less Input impedance Approx 10kW PNP ...

Reviews: