Item

Factory set

-

ting

Description

Emission 
level

If the incident light intensity is saturated, which makes 
sensing impossible or unreliable, you can reduce the 
emission level.

 

Level 3 (

): Normal

 

Level 2 (

): Approx. 40% of normal

 

Level 1 (

): Approx. 20% of normal

When you select Auto ( ), proper light intensity is 
automatically set only during limit teaching.

For differences between the conventional and 

modified units, see 

unIt VErsIons

 on page 

7.

Emission 
frequency

FX-102

-Z

FX-101

-Z

When using fiber heads in parallel, interference can be 

prevented by setting different emission frequencies. 
When emission frequency 0 is set, interference cannot 
be prevented. Response time corresponds to emission 
frequency. For details, see 

sPEcIFIcatIons

 on 

page 8.

Flowchart for sEttInG mode

run mode

Press for 2s.

sEttInG mode

Automatic

teaching

output operation

Light-ON

Dark-ON

timer operation

1, 5, 10, 20, 40, 50, 100, 500, 1000ms

Without timer

Timer delay

Timer delay

Timer delays setting mode

Timer delays setting mode

ON delay timer

OFF delay timer

Timer delays available (ms):

Emission level

Level 2

Level 3

Auto + Level 3

Level 1

Emission frequency

FX-101

-Z

FX-102

-Z

FX-101

-Z

FX-102

-Z

Emission 

frequency 0

Emission 

frequency 1

Emission frequencies available:

Emission frequencies available:

The operation indicator and the beam-emitting inlet blink while the 
emission frequency is being set. When the emission frequency is 
set to 0, they light up. The blinking cycle depends on each emission 

frequency (emission frequency 1: fast ↔ emission frequency 4: 

slow).

run mode

8

tEacHInG MoDE

Beware that detection may become unstable if too little margin 

between the theshold value and incident light intensity is al

-

lowed for the environment when teaching.

2-point teaching

2-point teaching is the most common teaching method and means the 
threshold value is taught using two points that correspond to the object 
present and object absent conditions. 

Light-ON or Dark-ON is determined automatically for the output operation 
setting.

Output indicator ON when object is present

In teaching mode, press <ON> when object is present to set 

the first incident light intensity.

Thru-beam type

Light interrupted 

condition

Light received condition

Mark

Reflective type

Base

Automatic

The first incident light intensity is set and is displayed in 

green. The red LED display blinks and is ready to be set to 
the object absent condition.
To cancel, press <MODE>.

Remove the object and press <OFF> to complete 2-point 
teaching.

Thru-beam type

Light received condition

Light interrupted condition

Mark

Reflective type

Base

Automatic

The margin between the first and second incident is displayed 

in red (P=%). When the margin is 200% or more, 

 is 

displayed.

Output indicator ON when object is absent

In teaching mode, press <ON> when object is absent to set 

the first incident light intensity.

Thru-beam type

Light received condition

Light interrupted condition

Mark

Reflective type

Base

Automatic

The first incident light intensity is set and is displayed in 

green. The red LED display blinks and is ready to be set to 
the object present condition.
To cancel, press <MODE>.

Place the object so that it is sensed and press <OFF> to 
complete 2-point teaching.

Thru-beam type

Light interrupted 

condition

Light received condition

Mark

Reflective type

Base

Automatic

The margin between the first and second incident is displayed 

in red (P=%). When the margin is 200% or more, 

 is 

displayed.

Summary of Contents for FX-100-Z Series

Page 1: ...t and steam Take care that the product does not come in contact with oil grease organic solvents such as thinner etc strong acid or alkalines This product cannot be used in an environment containing inflam mable or explosive gases Never disassemble or modify the product EEPROM is adopted to this product Teaching is limited to 100 000 times because of the EEPROM s lifetime 2 Part DEscrIPtIon 1 6 5 ...

Page 2: ...run MoDE Digital display When you turn ON the power the product name is indicated in green and the emission frequency is indicated in red Then the device automatically switches into RUN mode in which the threshold value is displayed in green and the incident light intensity in red Power ON Emission frequency Product name RUN mode Incident light intensity Threshold value Automatic What appears on t...

Page 3: ...ttle margin between the theshold value and incident light intensity is al lowed for the environment when teaching 2 point teaching 2 point teaching is the most common teaching method and means the threshold value is taught using two points that correspond to the object present and object absent conditions Light ON or Dark ON is determined automatically for the output operation setting Output indic...

Page 4: ...n the threshold value follow up cycle is set the threshold value is adjusted according to the shift based on the incident light intensity detected However the threshold value is not stored GETA function note 4 5 Variations can be reduced by setting the present incident light intensity for each amplifier to a certain value For example if this value is set to 2 000 and the incident light intensity i...

Page 5: ... point Sampling in progress NPN output type High NPN output type Low 1 Depending on the threshold value output may turn ON OFF when emission is halted or released 2 When emission starts output operation is undetermined during the response time If the output signal is received by a PLC for example set the amplifier s timer to 20ms response time or greater Example For the FX 101q Z with emission fre...

Page 6: ...to another amplifier repeat steps 3 to 7 If the power is not turned on at the same time the setting con tents may not be copied To cancel the setting copy function of the master amplifier 1 While the slave side amplifier is disconnected turn on the power of the master side amplifier 2 Press MODE for 2s 12 QuIcK sEttInG FunctIon Simply by selecting a quick setting number which are listed in the tab...

Page 7: ...1 0 4 3 2 1 4 3 2 1 45 40 35 30 25 20 15 10 5 50 E_oF E_of LtcP Ltc Auto Eco LtcP Ltc Auto Eco ON OFF Code 1st digit 4th digit 3rd digit 2nd digit Output operation Timer see note Emission amount setting Emission frequency ECO External input Shift see note For differences between the conventional and modified units see unIt VErsIons on page 7 14 Error InDIcatIon If the follow error codes are displa...

Page 8: ...ansistor Maximum source current 100mA Applied voltage 30V DC or less between output and V Residual voltage 1 5V or less at 100mA source current output operation Light ON or Dark ON selectable short circuit protection Incorporated External input NPN output type NPN non contact input Signal condition High 8V to V DC or Open Low 0 to 2V DC Source current 0 5mA or less Input impedance Approx 10kW PNP ...

Reviews: