coDE sEttInG FunctIon

Selecting codes allow you to set: output operation, timer, emission level, 
emission frequency, ECO, external input, and shift amount.

The factory setting is 

.

1

4

3

2

+

RUN mode

Press for 4s, passing the 

quick setting function

Select digit 

values

Activate, set 

digit 

Code setting

After last digit is set, 

code settings take 

effect!                  

Automatic

During the setting process, press <MODE> for 2s to cancel and 

return to RUN mode. After the last digit is set, code settings 

take effect!

Code table, modified unit

0

8

7

6

5

4

3

2

1

0

d

c

b

A

9

E

F

FX-101

-Z FX-102

-Z

D-on

L-on

non

ond 10ms
ond 40ms

ofd 10ms
ofd 40ms

non

ond 10ms
ond 40ms

ofd 10ms
ofd 40ms

3

1

2

Auto

OFF

OFF

ON

ON

0

3

2

1

0

3

2

1

0

1

0

3

2

1

2

3

1

4

3

2

1

4

3

2

1

2

1

4

3

2

3

4

45%

40%

35%

30%

25%

20%

15%

10%

5%

50%

E_oF

E_of

LtcP

Ltc-

Auto

Eco

LtcP

Ltc-

Auto

Eco
2-Pt

2-Pt

Incident light 

intensity test

Incident light 

intensity test

Code

1st digit

4th digit

3rd digit

2nd digit

Output 

operation

Timer

(see note)

Emission 

amount 

level

Emission 

frequency

ECO

External 

input

Shift

(see note)

Code table, conventional unit

0

8

7

6

5

4

3

2

1

0

9

FX-101

-Z FX-102

-Z

D-on

L-on

non

ond 10ms
ond 40ms

ofd 10ms
ofd 40ms

non

ond 10ms
ond 40ms

ofd 10ms
ofd 40ms

OFF

ON

3

2

1

0

3

2

1

0

4

3

2

1

4

3

2

1

45%

40%

35%

30%

25%

20%

15%

10%

5%

50%

E_oF

E_of

LtcP

Ltc-

Auto

Eco

LtcP

Ltc-

Auto

Eco

ON

OFF

Code

1st digit

4th digit

3rd digit

2nd digit

Output 

operation

Timer

(see note)

Emission 

amount 

setting

Emission 

frequency

ECO

External 

input

Shift

(see note)

For differences between the conventional and modified units, 

see unIt VErsIons on page 7.

14

Error InDIcatIon

If the follow error codes are displayed, please take appropriate measures.

Display

Error description

Measures

EEPROM writing error

Contact our office.

The load is short-circuited 
causing overcurrent.

Turn off the power, then check the load.

Communication error
Disconnection, connection 
failure, etc.

Check the wiring before using the setting 
copy function.

15

unIt VErsIons

Please note the difference between the modified unit and the conventional 

unit: the modified unit has a “P” mark near the beam emitting inlet. The 

conventional unit has no “P” mark.

Modified unit

Conventional unit

Beam emitting inlet

“P” mark 

The modified unit has some additional functionality.

 

The emission level has 4 possible settings. For the conventional unit, 
the emission level can only be turned ON (35%) or OFF.

 

For the external input, an incident light intensity test is available.

 

For teaching by external input, an additional option is available to turn 
ON/OFF the output every 100ms. See 

Pro MoDE

 on page 4.

 

Due to more functionality, more codes are available. See 

coDE sEt-

tInG FunctIon

 on page 7.

Summary of Contents for FX-100-Z Series

Page 1: ...t and steam Take care that the product does not come in contact with oil grease organic solvents such as thinner etc strong acid or alkalines This product cannot be used in an environment containing inflam mable or explosive gases Never disassemble or modify the product EEPROM is adopted to this product Teaching is limited to 100 000 times because of the EEPROM s lifetime 2 Part DEscrIPtIon 1 6 5 ...

Page 2: ...run MoDE Digital display When you turn ON the power the product name is indicated in green and the emission frequency is indicated in red Then the device automatically switches into RUN mode in which the threshold value is displayed in green and the incident light intensity in red Power ON Emission frequency Product name RUN mode Incident light intensity Threshold value Automatic What appears on t...

Page 3: ...ttle margin between the theshold value and incident light intensity is al lowed for the environment when teaching 2 point teaching 2 point teaching is the most common teaching method and means the threshold value is taught using two points that correspond to the object present and object absent conditions Light ON or Dark ON is determined automatically for the output operation setting Output indic...

Page 4: ...n the threshold value follow up cycle is set the threshold value is adjusted according to the shift based on the incident light intensity detected However the threshold value is not stored GETA function note 4 5 Variations can be reduced by setting the present incident light intensity for each amplifier to a certain value For example if this value is set to 2 000 and the incident light intensity i...

Page 5: ... point Sampling in progress NPN output type High NPN output type Low 1 Depending on the threshold value output may turn ON OFF when emission is halted or released 2 When emission starts output operation is undetermined during the response time If the output signal is received by a PLC for example set the amplifier s timer to 20ms response time or greater Example For the FX 101q Z with emission fre...

Page 6: ...to another amplifier repeat steps 3 to 7 If the power is not turned on at the same time the setting con tents may not be copied To cancel the setting copy function of the master amplifier 1 While the slave side amplifier is disconnected turn on the power of the master side amplifier 2 Press MODE for 2s 12 QuIcK sEttInG FunctIon Simply by selecting a quick setting number which are listed in the tab...

Page 7: ...1 0 4 3 2 1 4 3 2 1 45 40 35 30 25 20 15 10 5 50 E_oF E_of LtcP Ltc Auto Eco LtcP Ltc Auto Eco ON OFF Code 1st digit 4th digit 3rd digit 2nd digit Output operation Timer see note Emission amount setting Emission frequency ECO External input Shift see note For differences between the conventional and modified units see unIt VErsIons on page 7 14 Error InDIcatIon If the follow error codes are displa...

Page 8: ...ansistor Maximum source current 100mA Applied voltage 30V DC or less between output and V Residual voltage 1 5V or less at 100mA source current output operation Light ON or Dark ON selectable short circuit protection Incorporated External input NPN output type NPN non contact input Signal condition High 8V to V DC or Open Low 0 to 2V DC Source current 0 5mA or less Input impedance Approx 10kW PNP ...

Reviews: