7
13
coDE sEttInG FunctIon
Selecting codes allow you to set: output operation, timer, emission level,
emission frequency, ECO, external input, and shift amount.
The factory setting is
.
1
4
3
2
+
RUN mode
Press for 4s, passing the
quick setting function
Select digit
values
Activate, set
digit
Code setting
After last digit is set,
code settings take
effect!
Automatic
*
During the setting process, press <MODE> for 2s to cancel and
return to RUN mode. After the last digit is set, code settings
take effect!
Code table, modified unit
0
8
7
6
5
4
3
2
1
0
d
c
b
A
9
E
F
FX-101
□
-Z FX-102
□
-Z
D-on
L-on
non
ond 10ms
ond 40ms
ofd 10ms
ofd 40ms
non
ond 10ms
ond 40ms
ofd 10ms
ofd 40ms
3
1
2
Auto
OFF
OFF
ON
ON
0
3
2
1
0
3
2
1
0
1
0
3
2
1
2
3
1
4
3
2
1
4
3
2
1
2
1
4
3
2
3
4
45%
40%
35%
30%
25%
20%
15%
10%
5%
50%
E_oF
E_of
LtcP
Ltc-
Auto
Eco
LtcP
Ltc-
Auto
Eco
2-Pt
2-Pt
Incident light
intensity test
Incident light
intensity test
Code
1st digit
4th digit
3rd digit
2nd digit
Output
operation
Timer
(see note)
Emission
amount
level
Emission
frequency
ECO
External
input
Shift
(see note)
Code table, conventional unit
0
8
7
6
5
4
3
2
1
0
9
FX-101
□
-Z FX-102
□
-Z
D-on
L-on
non
ond 10ms
ond 40ms
ofd 10ms
ofd 40ms
non
ond 10ms
ond 40ms
ofd 10ms
ofd 40ms
OFF
ON
3
2
1
0
3
2
1
0
4
3
2
1
4
3
2
1
45%
40%
35%
30%
25%
20%
15%
10%
5%
50%
E_oF
E_of
LtcP
Ltc-
Auto
Eco
LtcP
Ltc-
Auto
Eco
ON
OFF
Code
1st digit
4th digit
3rd digit
2nd digit
Output
operation
Timer
(see note)
Emission
amount
setting
Emission
frequency
ECO
External
input
Shift
(see note)
*
For differences between the conventional and modified units,
see unIt VErsIons on page 7.
14
Error InDIcatIon
If the follow error codes are displayed, please take appropriate measures.
Display
Error description
Measures
EEPROM writing error
Contact our office.
The load is short-circuited
causing overcurrent.
Turn off the power, then check the load.
Communication error
Disconnection, connection
failure, etc.
Check the wiring before using the setting
copy function.
15
unIt VErsIons
Please note the difference between the modified unit and the conventional
unit: the modified unit has a “P” mark near the beam emitting inlet. The
conventional unit has no “P” mark.
Modified unit
Conventional unit
Beam emitting inlet
“P” mark
The modified unit has some additional functionality.
●
The emission level has 4 possible settings. For the conventional unit,
the emission level can only be turned ON (35%) or OFF.
●
For the external input, an incident light intensity test is available.
●
For teaching by external input, an additional option is available to turn
ON/OFF the output every 100ms. See
Pro MoDE
on page 4.
●
Due to more functionality, more codes are available. See
coDE sEt-
tInG FunctIon
on page 7.