3.Wiring Section

FV-01VCN1

LED Lead Assy 

High Voltage Lead Assy 

Peltier Lead Assy  

Nanoe Lead Assy  

Power Lead Assy  

MOTOR  Lead Assy 

When replacing the Lead Wire or Main PCB, please be sure to hold the Main PCB 
in place before pulling out the lead wire.  Otherwise the PCB may be deformed or 
damaged because it does not have screws.

Always take measures to prevent electrostatic discharge when handling these parts.

 

4

Main PCB Assembly  

Insert Motor lead 
into Y Shaped slot. 

Antistatic 
Gloves