14-22
Operation mode
-
The contents of special internal relays R9020 to R9027 are expressed as 2-character hexadecimal
values.
-
The user can check the settings of the mode selector switches on the CPU unit
(RUN/PROG./REMOTE), whether normal operation or test operation is being used, and other elements.
Values are read in binary notation, as shown below.
Error flag
The statuses of the eight error flags (special internal relays) R9000 to R9007 are expressed as 2-
character hexadecimal values. They are read using binary notation, as shown below.
Self-diagnostic error code
-
If an error occurs, the self-diagnosis error code is expressed as a 4-digit hexadecimal value. Please be
careful, since self-diagnosis error codes are normally treated as decimal values.
For example, if the content is read as “2D00” in hexadecimal format, the self-diagnosis error code will
be “2D”. In decimal notation it will be read as “45” (Operation error).
-
If no error has occurred, the value will be “0000”.
Summary of Contents for FP2 ET-LAN
Page 11: ...Chapter 1 Unit Functions and Restrictions ...
Page 14: ...1 4 1 1 4 Connecting to a Network AFP2790 100BASE TX 10BASE T 10BASE5 AUI AFP27901 ...
Page 24: ...1 14 ...
Page 25: ...Chapter 2 Names and Functions of Parts ...
Page 29: ...Chapter 3 Connection for LAN Cable ...
Page 37: ...Chapter 4 Confirming the Design Contents ...
Page 49: ...Chapter 5 Initialization Processing and Termination Processing ...
Page 68: ...5 20 ...
Page 69: ...Chapter 6 Open Processing and Close Processing ...
Page 84: ...6 16 ...
Page 85: ...Chapter 7 Computer Link Function ...
Page 94: ...7 10 Program example ...
Page 97: ...7 13 Example of communication data Same hierarchy communication ...
Page 100: ...7 16 Example of communication data Other hierarchy communication ...
Page 101: ...7 17 Other hierarchy communication for MEWTOCOL COM ...
Page 102: ...7 18 ...
Page 103: ...Chapter 8 Data Transfer Function ...
Page 111: ...8 9 Program example ...
Page 114: ...8 12 Example of communication data Same hierarchy communication ...
Page 117: ...8 15 Example of communication data Other hierarchy communication ...
Page 119: ...8 17 Other hierarchy communication for MEWTOCOL DAT ...
Page 120: ...8 18 ...
Page 121: ...Chapter 9 Transparent Communication Function ...
Page 137: ...9 17 Program example ...
Page 143: ...Chapter 10 Auto Connection ...
Page 155: ...10 13 Case 1 Ladder program example ...
Page 169: ...Chapter 11 E mail Function ...
Page 200: ...11 32 ...
Page 201: ...Chapter 12 Error Log Function ...
Page 203: ...12 3 Latest log block area Log block reading processing area ...
Page 219: ...Chapter 13 Troubleshooting ...
Page 224: ...13 6 13 2 4 Troubleshooting Flowchart ...
Page 225: ...13 7 ...
Page 229: ...Chapter 14 MEWTOCOL Communication Procedure ...
Page 242: ...14 14 To write to an index register ...
Page 262: ...14 34 ...
Page 263: ...Chapter 15 Specifications ...
Page 292: ...15 30 15 6 ASCII Codes ...
Page 293: ...15 31 15 7 Dimensions AFP2790 FP2 ET1 AFP27901 FP2 ET2 ...
Page 294: ......
Page 295: ...Chapter 16 Sample Program ...
Page 298: ...16 4 ...
Page 299: ...16 5 ...
Page 300: ...16 6 ...
Page 301: ...16 7 ...
Page 304: ......
Page 305: ......