9-2
9.1 An Overview of the Transparent Communication
Function
9.1.1
What is the Transparent Communication Function?
With the transparent communication function, data can be sent and received transparently between a
computer and a programmable controller, and between two programmable controllers.
Communication data can be stored to and retrieved from the programmable controller by reading from
and writing to the reception buffer of the shared memory in the ET-LAN unit. Communication requests
and other commands are executed by the bits of the handshake area in the I/O or shared memory being
turned on and off.
Key Point:
-
With the transparent communication function, the programmable controller or computer specifies an IP
address to open a connection with the communication destination.
-
After the connection has been opened, communication processing on the programmable controller side
is carried out by data being read from or written to the communication buffer of the shared memory
through the ladder program, and by communication requests being executed.
-
Up to eight connections can be used on a single ET-LAN unit by using the transparent communication
function in conjunction with MEWTOCOL communication functions (computer linking and data transfer).
Summary of Contents for FP2 ET-LAN
Page 11: ...Chapter 1 Unit Functions and Restrictions ...
Page 14: ...1 4 1 1 4 Connecting to a Network AFP2790 100BASE TX 10BASE T 10BASE5 AUI AFP27901 ...
Page 24: ...1 14 ...
Page 25: ...Chapter 2 Names and Functions of Parts ...
Page 29: ...Chapter 3 Connection for LAN Cable ...
Page 37: ...Chapter 4 Confirming the Design Contents ...
Page 49: ...Chapter 5 Initialization Processing and Termination Processing ...
Page 68: ...5 20 ...
Page 69: ...Chapter 6 Open Processing and Close Processing ...
Page 84: ...6 16 ...
Page 85: ...Chapter 7 Computer Link Function ...
Page 94: ...7 10 Program example ...
Page 97: ...7 13 Example of communication data Same hierarchy communication ...
Page 100: ...7 16 Example of communication data Other hierarchy communication ...
Page 101: ...7 17 Other hierarchy communication for MEWTOCOL COM ...
Page 102: ...7 18 ...
Page 103: ...Chapter 8 Data Transfer Function ...
Page 111: ...8 9 Program example ...
Page 114: ...8 12 Example of communication data Same hierarchy communication ...
Page 117: ...8 15 Example of communication data Other hierarchy communication ...
Page 119: ...8 17 Other hierarchy communication for MEWTOCOL DAT ...
Page 120: ...8 18 ...
Page 121: ...Chapter 9 Transparent Communication Function ...
Page 137: ...9 17 Program example ...
Page 143: ...Chapter 10 Auto Connection ...
Page 155: ...10 13 Case 1 Ladder program example ...
Page 169: ...Chapter 11 E mail Function ...
Page 200: ...11 32 ...
Page 201: ...Chapter 12 Error Log Function ...
Page 203: ...12 3 Latest log block area Log block reading processing area ...
Page 219: ...Chapter 13 Troubleshooting ...
Page 224: ...13 6 13 2 4 Troubleshooting Flowchart ...
Page 225: ...13 7 ...
Page 229: ...Chapter 14 MEWTOCOL Communication Procedure ...
Page 242: ...14 14 To write to an index register ...
Page 262: ...14 34 ...
Page 263: ...Chapter 15 Specifications ...
Page 292: ...15 30 15 6 ASCII Codes ...
Page 293: ...15 31 15 7 Dimensions AFP2790 FP2 ET1 AFP27901 FP2 ET2 ...
Page 294: ......
Page 295: ...Chapter 16 Sample Program ...
Page 298: ...16 4 ...
Page 299: ...16 5 ...
Page 300: ...16 6 ...
Page 301: ...16 7 ...
Page 304: ......
Page 305: ......