18.2 Direct Input Instruction
18-9
18.2 Direct Input Instruction
18.2.1 [DST·DST/] Direct start / Direct start NOT
DST, DST/: reads external inputs for logical operation. Due to the input refreshing of contact
units, it is valid for controls with requirement for high-speed response.
Instruction format
X0
D
R0
X1
D
R1
DST
DST/
Type of relays that can be specified (unit: bit) (A: Availalbe, -: Not available))
X Y R T C L P E
Index
modifier
DST
Normal ON input contact for the start of
logical operation
A
-
-
-
-
-
-
-
A
DST/
Normal OFF input contact for the start of
logical operation
A
-
-
-
-
-
-
-
A
Operation description
•
「
DST
」
Instruction, read specified external input, reflect it to the input contact, and then take
this contact as normally open (NO) contact (a contact) and perform logic operation.
•
「
DST/
」
Instruction, read specified external input, reflect it to the input contact, and then take
this contact as normally closed (NC) contact (b contact) and perform logic operation.
<Example> During the above procedure
•
When external input X0 flag is ON, R0 flag will be ON.
•
When external input X1 flag is OFF, R1 flag will be ON.
Range that can be specified
Model
Device Range
FP-XH M8N control unit
X0-X7·X1100-X141F (Note)
(Note): When designating X1100-X141F, the input area of the motion control part is read and reflected.
Precautions for programs
•
When the contact is out of the specified possible range, operation error may occur.
•
When setting the time through main unit input time constant setting function of system
register, the time constant will be invalid.
Summary of Contents for FP-XH M8N16PD
Page 1: ......
Page 23: ...1 System Structure ...
Page 39: ...2 Control Unit Specifications ...
Page 48: ...Control Unit Specifications 2 10 ...
Page 49: ...3 I O Allocation ...
Page 77: ...4 Installation ...
Page 89: ...5 Wiring of Power Supply and General purpose I O Parts ...
Page 104: ...Wiring of Power Supply and General purpose I O Parts 5 16 ...
Page 105: ...6 Wiring of Motion I O Parts ...
Page 116: ...Wiring of Motion I O Parts 6 12 ...
Page 117: ...7 Power On Off and Check Items ...
Page 124: ...Power On Off and Check Items 7 8 ...
Page 125: ...8 Steps Before Running ...
Page 142: ...Steps Before Running 8 18 ...
Page 143: ...9 Setting of Position Control Parameters ...
Page 159: ...10 Transfer to Unit and Commissioning ...
Page 181: ...11 Automatic Operation Position Control ...
Page 193: ...11 2 Interpolation Control 11 13 ...
Page 209: ...12 Automatic Operation Synchronous Control ...
Page 251: ...13 Manual Operation JOG Operation ...
Page 256: ...Manual Operation JOG Operation 13 6 ...
Page 257: ...14 Manual Operation Home Return ...
Page 264: ...Manual Operation Home Return 14 8 ...
Page 265: ...15 Pulse Input Function ...
Page 278: ...Pulse Input Function 15 14 ...
Page 279: ...16 Stop Function ...
Page 285: ...17 Auxiliary Function ...
Page 329: ...18 Instruction Reference ...
Page 357: ...19 Error Warning Annunciation Function ...
Page 386: ...Error Warning Annunciation Function 19 30 ...
Page 387: ...20 Troubleshooting ...
Page 402: ...Troubleshooting 20 16 ...
Page 403: ...21 Memory Master Memory Cassette ...
Page 418: ...Memory Master Memory Cassette 21 16 ...
Page 419: ...22 Security Functions ...
Page 430: ...Security Functions 22 12 ...
Page 431: ...23 General purpose Input High speed counter Function ...
Page 448: ...General purpose Input High speed counter Function 23 18 ...
Page 449: ...24 Other Functions ...
Page 452: ...Other Functions 24 4 ...
Page 453: ...25 Maintenance and Inspection ...
Page 457: ...26 Specifications ...
Page 552: ...Specifications 26 96 ...
Page 553: ...Record of changes Manual No Date Record of Changes WUME FPXHM8N16PD 01 Sep 2017 First Edition ...
Page 554: ......
Page 555: ......
Page 556: ......