VXL40H
37
Furtherinformation
Functionsofdirtsensor
The sensor detects the dirtiness of the air, and the clean
indicator shows the dirtiness level. When [Auto] or
[Silent] is set, the product will operate with the air
volume corresponding to the type of dirtiness.
●
The product may not sense the dirt depending on
airflow, for example, when a heater is placed nearby.
Detect
May detect
● PM 2.5 (smoke of cigarette, dust, etc.)
● House dust (dust, dead bodies and
excreta of ticks, mold spores, pollen)
● Smoke (cigarette, incense, etc.)
● oil fumes, water
vapor
Sleepmodeautooperation
The product detects the indoor brightness with the light sensor and controls the brightness of indicators of the control
panel and air volume automatically. (The initial setting is [Sleep mode auto 1].)
●
The brightness of indicators in "Sleep mode
auto operation" can be changed.
Stop operation, then press and hold
and
simultaneously.
(The humidity indicator is lit in turn.)
Release the buttons when the brightness
reaches you want.
Setting
Control panel
Indoor brightness
dim
dark
Sleep mode
auto 1
Clean indicator
Econavi indicator
nanoe™ indicator
Half on
Off
Other than above
All on
Half on
Sleep mode
auto 2
Clean indicator
Econavi indicator
nanoe™ indicator
Half on
Half on
Other than above
All on
Without "Sleep
mode auto
operation"
Clean indicator
Econavi indicator
nanoe™ indicator
All on
Other than above
●
When the air volume is set at [Hi] or [Lo], even while "Sleep mode auto operation" is set,
the air volume is kept unchanged.
Econavioperation
It is the automatic operation by combining the “patrol mode” in which the product checks the dirt in the air in the
room every hour, with the “learning mode” in which the product can forecast the dirt generation by mastering the
generation time of dirt every day.
It saves power by stopping operation automatically when the air is clean. Meanwhile, the product will operate in
advance to eliminate the dirt effectively before spreading, thus reducing the operation time.
Patrol mode
Theproductwillstopoperatingautomaticallyaftertheairis
cleaned.Aftertheoperationispausedfor50minutes,theproduct
willoperatefor10minutesinthepatrolmode.
(Airvolumeiscontrolledbetween[Lo]and[Hi].)
●
While the operation is paused and in the patrol mode, if the dirt is
detected, the product will operate with the air volume corresponding to
the level of dirtiness.
●
While humidifying, even if the dirt is not detected, the product will
operate corresponding to the ambient humidity.
Learning mode
Duringoperation,theproductmemorizesthetimeanddirtinesslevel,andthenextday,itwillrunthe
preventiveoperation5minutesbeforethememorizedtime.
(The memory is updated every day. If it is disconnected, the previous memory is erased.)
Humidity indicator shows:
Sleep mode auto 2
Sleep mode auto 1
Without "Sleep mode
auto operation"